ECFG Superstore › BAD › 6.4.1.8
MY ACCOUNT / MY FILES →Cummins BAD 6.4.1.8 ECFG — ISB6.7 CM2100 tuning definition
Cummins BAD 6.4.1.8 ECFG — the ECFG definition file (Cummins DAMOS equivalent) for ISB6.7 (Midrange on-highway) on the CM2100 ECM: 12,795 named parameters for Calterm / WinOLS tuning — torque, fuelling, boost/VGT, EGR, DPF, SCR/DEF, speed limiter and fault-code tables. Build ID —, created 2011-10-17. Instant download after PayPal checkout.
FormatECFG — Engineering Tool Config File (XML)Product ID
BADSoftware version6.4.1.8ModuleCM2100ECU platformCM2100 / CM2150 PV midrange (2008-2012)EngineISB6.7Application / marketMidrange on-highwayEmissionsEPA07ProgramMR-MH07-C16.20.00.00-P06.04.01.08 - CM2150_PVBuild ID—Creation date2011-10-17Copyright year2011Parameters12,795 named parameters (<parameter> records)Interface level4.5.4.0First prod cfg file version2003.1.1.0Module part number9999999Boot loader range1.0.2.0 → 1.0.9.9Byte orderBigEndianIndex table address0x00042000Price$100 · instant download after PayPal checkoutHeader CRC5734File size9.1 MBArchive copies9 copies heldFormatECFG XML (Engineering Tool Config File) · opens in Cummins Calterm; converts to WinOLS map pack / A2L on request<Engineering_Tool_Config_File version="6.4.1.8" crc="5734">
<compatibility_header>
<calibration_version>6.4.1.8</calibration_version>
<module_name>CM2100</module_name>
<product_id>BAD</product_id>
<file_descriptor>Core-II Software Copyright 2011 Cummins Inc. - Cummins Confidential - MR-MH07-C16.20.00.00-P06.04.01.08 - CM2150_PV</file_descriptor>
What is inside this ECFG
12,795 parameters — 1,662 tables / axes. Counts by area (a parameter can sit in more than one):
638Torque / power
674Fuelling / rail
519Boost / turbo / VGT
450EGR
773DPF / DOC / regen
143SCR / DEF / NOx
726Speed / cruise / idle
487Fault codes / derates
674Sensors / calibration
| Parameter | Area | Description | Units |
|---|---|---|---|
| ACA_Torque | Torque / power | Torque consumed by all ACAs. | N_m |
| ACA_Torque_Max | Torque / power | Torque value that all ACA can consume at most. | N_m |
| Actual_Eng_Ind_Perc_Trq_Hi_Res | Torque / power | Parameter is used for broadcasting the high resolution portion of torque that goes with Actual_Eng_Indicated_Perc_Trq on J1939. | % |
| Actual_Eng_Indicated_Perc_Trq | Torque / power | Parameter is used for broadcasting Actual Engine Percent Torque on the datalink | % |
| Actual_Max_Available_Eng_Perc_Trq | Torque / power | Parameter is used for broadcasting Actual Maximum Available Engine - Percent Torque (SPN 3357) through datalink. It is the maximum amount of torque that the eng | % |
| AH_Fuel_Derate_Latch | Fuelling / rail | [AHFLDRLA] Indicates turbo overspeed protection fuel derate [From 02 -- Units: UNITLESS Size:2 Digits:0 Signed:U Scalar:1] [Jims comp:{EMM}] | None |
| AIF_AlphaFuelRate | Fuelling / rail | Alpha request from fuel rate section of the Alpha algorithm (boolean 0 or 1) [From 02 -- Units: UNITLESS Size:2 Digits:0 Signed:U Scalar:1] [Jims comp:{EMM | None |
| AIF_FuelRate | Fuelling / rail | Fuel Rate algorithm as determined by the alpha determination algorithm. | kg/hr |
| Audit_Trail | Fuelling / rail | Data space reserved in the ECM as a scratchpad for tools to record changes they have requested of the ECM. Reference CES14278 and GTIS requirements. | |
| CBL_Fuel_Cmd | Fuelling / rail | Fuel command after imposing combustion limits [From 02 -- Units: MG/STROKE Size:2 Digits:2 Signed:U Scalar:0.067934782] [Jims comp:{CBM}] | mg/stroke |
| AIF_AlphaAAPTurboProt | Boost / turbo / VGT | [APAAPRSS] Alpha contribution from ambient air pressure logic of the alopha algoirthm (boolean 0 or 1) [From 02 -- Units: UNITLESS Size:2 Digits:2 Sign | None |
| BPS_BoostEngaged | Boost / turbo / VGT | Hook identifying that Boost Power is actively engaged. | None |
| BVC_s_LowBoostVoltage | Boost / turbo / VGT | low boost voltage indicator | None |
| Boost_Power_Request_Switch | Boost / turbo / VGT | Debounced value of the Boost Power Request Switch. | None |
| Boost_Pressure | Boost / turbo / VGT | Gage value of linearized and filtered Charge Press. | kPa_G |
| Adjusted_EGR_Fraction | EGR | Adjusted EGR fraction Engine Out PM Estimate. It is equal to EGR_Fraction+EGR_Fraction_Adjustment | None |
| CBL_EGR_Frac_Cmd | EGR | EGR fraction command passed to Charge Manager from Combustion Manager [From 02 -- Units: UNITLESS Size:2 Digits:3 Signed:U Scalar:0.00012207] [Jims co | None |
| CBM_Dosing_Prohibit_EGR | EGR | Prohibits EGR Control when In-cylinder dosing is active | None |
| CBO_EGR_Frac_CTLimit | EGR | This value is TRUE when EGR Fraction Reference is being limited due to Coolant Temperature | None |
| CBO_EGR_Frac_IMTLimit | EGR | This value is TRUE when EGR Fraction Reference is being limited due to Charge Temperature | None |
| ATM_DPF_Backpressure_Factor | DPF / DOC / regen | A table-based index calculated by ATM that indicates high DPF dP that is not in agreement with estimated soot load. | None |
| CBM_DPF_BackPress_Factor | DPF / DOC / regen | Indicates high DPF delta pressure that is not in agreement with estimated soot load. | None |
| CBO_MTRegen_Fuel_Diff_Hold_Cond | DPF / DOC / regen | For manual transmission in Regen, when TRUE indicates the timer of CBO fuel diff value less than C_CBO_Trans_Fuel_Delta is expired | None |
| CBO_MTRegen_VGT_ULim_Time_Out | DPF / DOC / regen | For manual transmission in Regen,when TRUE indicates fuel diff less than C_CBO_Trans_Fuel_Delta timer expired. | None |
| C_AIM_FT_DOCInTmptr_Enbl | DPF / DOC / regen | For map this parameter to Catalyst_Inlet_Temperature_Sensor_Enable | None |
| Auxiliary_Discrete_Input_1 | SCR / DEF / NOx | Auxiliary Discrete Input 1 Switch | None |
| CBR_NOx_Out_Frac | SCR / DEF / NOx | NOx mass fraction from the estimator | None |
| CBR_NOx_Out_PPM | SCR / DEF / NOx | NOx out ppm passed to ATM ( DRB06/21--since it is related to some other uses, it is defined as B13) | None |
| CBR_NOx_Target_Ref | SCR / DEF / NOx | NOx target reference [From 02 -- Units: G/HP*HR Size:2 Digits:3 Signed:U Scalar:0.000488281] [Jims comp:{CBM}] | g/HP*hr |
| C_ABS_Rmt_Throttle_Def_Gov | SCR / DEF / NOx | This parameter determines what is the default governor when remote throttle is active and T_SwitchableGovernorEnable is disabled. This would eliminate the need | |
| AFW_Idle_Speed | Speed / cruise / idle | The idle speed calculated by the Alternator Failure warning feature | RPM |
| AIF_AlphaGovernor | Speed / cruise / idle | [APGVAP] result of On Governor logic (boolean 0 or 1) [From 02 -- Units: UNITLESS Size:2 Digits:0 Signed:U Scalar:1] [Jims comp:{EMM}] | None |
| APP_On_Idle | Speed / cruise / idle | Indicates whether or not the Accelerator is in the Idle position. Value is determined by either idle validation switches or Secondary_Accel_Pedal_Pos, dependin | None |
| AP_Low_Idle_Switch | Speed / cruise / idle | Switch signal which indicates whether the accelerator pedal low idle switch is opened or closed. 0x00 Accelerator pedal not in low idle condition 0x01 Accel | None |
| Accelerator_Governor_Switch | Speed / cruise / idle | Debounced value of Accelerator Governor Switch physical input. When TRUE, this input causes Selected_Governor to toggle from "ABS" to "ABT" or vice versa depe | None |
| AIF_AlphaAltDerate_Timer | Fault codes / derates | semaphore used to latch AFC events that occur between alpha executions | s |
| CAGT_Block_Fault_Codes | Fault codes / derates | Array of fault codes to be blocked. Fault codes can be found in CES14602 specification. | |
| CBM_Permit_FSO_Diagnosis | Fault codes / derates | Permit FSO Diagnosis Indicator | None |
| CBR_Density_Derate_Error | Fault codes / derates | Error due to Air Density silent derate | None |
| CBR_Density_Derate_Fault_Timer | Fault codes / derates | Air Density fault timer count | s |
| AIP_WIF_Sensor_Voltage | Sensors / calibration | analog voltage for water in fuel sensor input | V |
| APC_v_DslPrsSensor | Sensors / calibration | Diesel Rail Pressure Sensor Voltage (ref to 5V) | V |
| APP2_Sensor_Supply_Voltage | Sensors / calibration | Secondary Accelerator Sensor supply voltage detected by the ECM. | V |
| APP2_Sensor_Voltage | Sensors / calibration | Sensor input voltage detected by the ECM for Secondary Accelerator. | V |
| Accel_Position_Sensor_Volts | Sensors / calibration | sensor voltage detected by the ECM. | V |
Sample of named calibration parameters with their Cummins descriptions. The full ECFG lists every parameter with ITN address, data type, scaling, limits and units.
Other BAD versions (10)
6.4.0.9ECFG · CM2100 · 2007-11-146.4.0.12ECFG · CM2100 · 2008-05-296.4.0.15ECFG · CM2100 · 2009-01-296.4.1.3ECFG · CM2100 · 2010-01-136.4.1.5ECFG · CM2100 · 2010-08-176.4.1.10ECFG · CM2100 · 2012-05-216.4.1.10ECFG · CM2100 · 2010-01-136.4.1.12ECFG · CM2100 · 2012-11-126.4.2.1ECFG · CM2100 · 2013-07-318.52.0.1ECFG · CM2100 · 2007-04-26
Buy & download
Loading checkout…