ECFG Superstore › BAE › 6.4.1.10
MY ACCOUNT / MY FILES →

Cummins BAE 6.4.1.10 ECFG — ISC8.3 CM2100 tuning definition

Cummins BAE 6.4.1.10 ECFG — the ECFG definition file (Cummins DAMOS equivalent) for ISC8.3 (Midrange on-highway) on the CM2100 ECM: 12,815 named parameters for Calterm / WinOLS tuning — torque, fuelling, boost/VGT, EGR, DPF, SCR/DEF, speed limiter and fault-code tables. Build ID —, created 2012-05-21. Instant download after PayPal checkout.

FormatECFG — Engineering Tool Config File (XML)Product IDBAESoftware version6.4.1.10ModuleCM2100ECU platformCM2100 / CM2150 PV midrange (2008-2012)EngineISC8.3Application / marketMidrange on-highwayEmissionsEPA07ProgramMR-MH07-C16.20.00.00-P06.04.01.10 - CM2150_PVBuild ID—Creation date2012-05-21Copyright year2012Parameters12,815 named parameters (<parameter> records)Interface level4.5.4.0First prod cfg file version2003.1.1.0Module part number9999999Boot loader range1.0.2.0 → 1.0.9.9Byte orderBigEndianIndex table address0x00042000Price$100 · instant download after PayPal checkoutHeader CRCFE9EFile size8.8 MBArchive copies8 copies heldFormatECFG XML (Engineering Tool Config File) · opens in Cummins Calterm; converts to WinOLS map pack / A2L on request
<Engineering_Tool_Config_File version="6.4.1.10" crc="FE9E"> <compatibility_header> <calibration_version>6.4.1.10</calibration_version> <module_name>CM2100</module_name> <product_id>BAE</product_id> <file_descriptor>Core-II Software Copyright 2012 Cummins Inc. - Cummins Confidential - MR-MH07-C16.20.00.00-P06.04.01.10 - CM2150_PV</file_descriptor>

What is inside this ECFG

12,815 parameters — 1,662 tables / axes. Counts by area (a parameter can sit in more than one):

639Torque / power
675Fuelling / rail
519Boost / turbo / VGT
450EGR
773DPF / DOC / regen
143SCR / DEF / NOx
726Speed / cruise / idle
487Fault codes / derates
674Sensors / calibration
ParameterAreaDescriptionUnits
ACA_TorqueTorque / powerTorque consumed by all ACAs.N_m
ACA_Torque_MaxTorque / powerTorque value that all ACA can consume at most.N_m
Actual_Eng_Ind_Perc_Trq_Hi_ResTorque / powerParameter is used for broadcasting the high resolution portion of torque that goes with Actual_Eng_Indicated_Perc_Trq on J1939.%
Actual_Eng_Indicated_Perc_TrqTorque / powerParameter is used for broadcasting Actual Engine Percent Torque on the datalink%
Actual_Max_Available_Eng_Perc_TrqTorque / powerParameter is used for broadcasting Actual Maximum Available Engine - Percent Torque (SPN 3357) through datalink. It is the maximum amount of torque that the eng%
AH_Fuel_Derate_LatchFuelling / rail[AHFLDRLA] Indicates turbo overspeed protection fuel derate [From 02 -- Units: UNITLESS Size:2 Digits:0 Signed:U Scalar:1] [Jims comp:{EMM}]None
AIF_AlphaFuelRateFuelling / railAlpha request from fuel rate section of the Alpha algorithm (boolean 0 or 1) [From 02 -- Units: UNITLESS Size:2 Digits:0 Signed:U Scalar:1] [Jims comp:{EMMNone
AIF_FuelRateFuelling / railFuel Rate algorithm as determined by the alpha determination algorithm.kg/hr
Audit_TrailFuelling / railData space reserved in the ECM as a scratchpad for tools to record changes they have requested of the ECM. Reference CES14278 and GTIS requirements.
CBL_Fuel_CmdFuelling / railFuel command after imposing combustion limits [From 02 -- Units: MG/STROKE Size:2 Digits:2 Signed:U Scalar:0.067934782] [Jims comp:{CBM}]mg/stroke
AIF_AlphaAAPTurboProtBoost / turbo / VGT[APAAPRSS] Alpha contribution from ambient air pressure logic of the alopha algoirthm (boolean 0 or 1) [From 02 -- Units: UNITLESS Size:2 Digits:2 SignNone
BPS_BoostEngagedBoost / turbo / VGTHook identifying that Boost Power is actively engaged.None
BVC_s_LowBoostVoltageBoost / turbo / VGTlow boost voltage indicatorNone
Boost_Power_Request_SwitchBoost / turbo / VGTDebounced value of the Boost Power Request Switch.None
Boost_PressureBoost / turbo / VGTGage value of linearized and filtered Charge Press.kPa_G
Adjusted_EGR_FractionEGRAdjusted EGR fraction Engine Out PM Estimate. It is equal to EGR_Fraction+EGR_Fraction_AdjustmentNone
CBL_EGR_Frac_CmdEGREGR fraction command passed to Charge Manager from Combustion Manager [From 02 -- Units: UNITLESS Size:2 Digits:3 Signed:U Scalar:0.00012207] [Jims coNone
CBM_Dosing_Prohibit_EGREGRProhibits EGR Control when In-cylinder dosing is activeNone
CBO_EGR_Frac_CTLimitEGRThis value is TRUE when EGR Fraction Reference is being limited due to Coolant TemperatureNone
CBO_EGR_Frac_IMTLimitEGRThis value is TRUE when EGR Fraction Reference is being limited due to Charge TemperatureNone
ATM_DPF_Backpressure_FactorDPF / DOC / regenA table-based index calculated by ATM that indicates high DPF dP that is not in agreement with estimated soot load.None
CBM_DPF_BackPress_FactorDPF / DOC / regenIndicates high DPF delta pressure that is not in agreement with estimated soot load.None
CBO_MTRegen_Fuel_Diff_Hold_CondDPF / DOC / regenFor manual transmission in Regen, when TRUE indicates the timer of CBO fuel diff value less than C_CBO_Trans_Fuel_Delta is expiredNone
CBO_MTRegen_VGT_ULim_Time_OutDPF / DOC / regenFor manual transmission in Regen,when TRUE indicates fuel diff less than C_CBO_Trans_Fuel_Delta timer expired.None
C_AIM_FT_DOCInTmptr_EnblDPF / DOC / regenFor map this parameter to Catalyst_Inlet_Temperature_Sensor_EnableNone
Auxiliary_Discrete_Input_1SCR / DEF / NOxAuxiliary Discrete Input 1 SwitchNone
CBR_NOx_Out_FracSCR / DEF / NOxNOx mass fraction from the estimatorNone
CBR_NOx_Out_PPMSCR / DEF / NOxNOx out ppm passed to ATM ( DRB06/21--since it is related to some other uses, it is defined as B13)None
CBR_NOx_Target_RefSCR / DEF / NOxNOx target reference [From 02 -- Units: G/HP*HR Size:2 Digits:3 Signed:U Scalar:0.000488281] [Jims comp:{CBM}]g/HP*hr
C_ABS_Rmt_Throttle_Def_GovSCR / DEF / NOxThis parameter determines what is the default governor when remote throttle is active and T_SwitchableGovernorEnable is disabled. This would eliminate the need
AFW_Idle_SpeedSpeed / cruise / idleThe idle speed calculated by the Alternator Failure warning featureRPM
AIF_AlphaGovernorSpeed / cruise / idle[APGVAP] result of On Governor logic (boolean 0 or 1) [From 02 -- Units: UNITLESS Size:2 Digits:0 Signed:U Scalar:1] [Jims comp:{EMM}]None
APP_On_IdleSpeed / cruise / idleIndicates whether or not the Accelerator is in the Idle position. Value is determined by either idle validation switches or Secondary_Accel_Pedal_Pos, dependinNone
AP_Low_Idle_SwitchSpeed / cruise / idleSwitch signal which indicates whether the accelerator pedal low idle switch is opened or closed. 0x00 Accelerator pedal not in low idle condition 0x01 AccelNone
Accelerator_Governor_SwitchSpeed / cruise / idleDebounced value of Accelerator Governor Switch physical input. When TRUE, this input causes Selected_Governor to toggle from "ABS" to "ABT" or vice versa depeNone
AIF_AlphaAltDerate_TimerFault codes / deratessemaphore used to latch AFC events that occur between alpha executionss
CAGT_Block_Fault_CodesFault codes / deratesArray of fault codes to be blocked. Fault codes can be found in CES14602 specification.
CBM_Permit_FSO_DiagnosisFault codes / deratesPermit FSO Diagnosis IndicatorNone
CBR_Density_Derate_ErrorFault codes / deratesError due to Air Density silent derateNone
CBR_Density_Derate_Fault_TimerFault codes / deratesAir Density fault timer counts
AIP_WIF_Sensor_VoltageSensors / calibrationanalog voltage for water in fuel sensor inputV
APC_v_DslPrsSensorSensors / calibrationDiesel Rail Pressure Sensor Voltage (ref to 5V)V
APP2_Sensor_Supply_VoltageSensors / calibrationSecondary Accelerator Sensor supply voltage detected by the ECM.V
APP2_Sensor_VoltageSensors / calibrationSensor input voltage detected by the ECM for Secondary Accelerator.V
Accel_Position_Sensor_VoltsSensors / calibrationsensor voltage detected by the ECM.V

Sample of named calibration parameters with their Cummins descriptions. The full ECFG lists every parameter with ITN address, data type, scaling, limits and units.

Other BAE versions (10)

6.4.0.9ECFG · CM2100 · 2007-11-146.4.0.12ECFG · CM2100 · 2008-05-296.4.0.15ECFG · CM2100 · 2009-01-296.4.1.3ECFG · CM2100 · 2010-01-136.4.1.5ECFG · CM2100 · 2010-08-176.4.1.5ECFG · CM2100 · 2010-08-176.4.1.8ECFG · CM2100 · 2011-10-176.4.1.12ECFG · CM2100 · 2012-11-126.4.2.1ECFG · CM2100 · 2013-07-316.4.2.1ECFG · CM2150 · 2013-07-31
Buy & download
Loading checkout…
Custom file service on your .xcal: DTC / full delete, extra HP, VGT delete