ECFG Superstore › BAQ › 18.1.0.21
MY ACCOUNT / MY FILES →

Cummins BAQ 18.1.0.21 ECFG — Powergen (CM850) CM850 tuning definition

Cummins BAQ 18.1.0.21 ECFG — the ECFG definition file (Cummins DAMOS equivalent) for Powergen (CM850) (Generator / G-Drive) on the CM850 ECM: 8,818 named parameters for Calterm / WinOLS tuning — torque, fuelling, boost/VGT, EGR, DPF, SCR/DEF, speed limiter and fault-code tables. Build ID 223615, created 2019-03-25. Instant download after PayPal checkout.

FormatECFG — Engineering Tool Config File (XML)Product IDBAQSoftware version18.1.0.21ModuleCM850ECU platformCM850 / CM870 Core-II (2003-2007)EnginePowergen (CM850)Application / marketGenerator / G-DriveProgramMR_Powergen_CM850-C-C18.00.00.08-MPG18.1.0.21Build ID223615Creation date2019-03-25Copyright year2019Parameters8,818 named parameters (<parameter> records)Interface level4.5.4.0First prod cfg file version2003.1.1.0Module part number3954430Boot loader range4.7.1.2 → 4.7.9.9Byte orderBigEndianIndex table address0x00510000Price$100 · instant download after PayPal checkoutHeader CRC5754File size6.1 MBArchive copies1 copy heldFormatECFG XML (Engineering Tool Config File) · opens in Cummins Calterm; converts to WinOLS map pack / A2L on request
<Engineering_Tool_Config_File version="18.1.0.21" crc="5754"> <compatibility_header> <calibration_version>18.1.0.21</calibration_version> <module_name>CM850</module_name> <product_id>BAQ</product_id> <file_descriptor>Core-II Software Copyright 2019 Cummins Inc. - Cummins Confidential - MR_Powergen_CM850-C-C18.00.00.08-MPG18.1.0.21 - Build ID - 223615</file_descriptor>

What is inside this ECFG

8,818 parameters — 1,278 tables / axes. Counts by area (a parameter can sit in more than one):

584Torque / power
467Fuelling / rail
358Boost / turbo / VGT
49EGR
16DPF / DOC / regen
52SCR / DEF / NOx
493Speed / cruise / idle
385Fault codes / derates
653Sensors / calibration
ParameterAreaDescriptionUnits
ACA_TorqueTorque / powerTorque consumed by all ACAs.N_m
ACA_Torque_MaxTorque / powerTorque value that all ACA can consume at most.N_m
Actual_Eng_Ind_Perc_Trq_Hi_ResTorque / powerParameter is used for broadcasting the high resolution portion of torque that goes with Actual_Eng_Indicated_Perc_Trq on J1939.%
Actual_Eng_Indicated_Perc_TrqTorque / powerParameter is used for broadcasting Actual Engine Percent Torque on the datalink%
Actual_Max_Available_Eng_Perc_TrqTorque / powerParameter is used for broadcasting Actual Maximum Available Engine - Percent Torque (SPN 3357) through datalink. It is the maximum amount of torque that the eng%
AH_Fuel_Derate_LatchFuelling / rail[AHFLDRLA] Indicates turbo overspeed protection fuel derate [From 02 -- Units: UNITLESS Size:2 Digits:0 Signed:U Scalar:1] [Jims comp:{EMM}]None
AIF_AlphaFuelRateFuelling / railAlpha request from fuel rate section of the Alpha algorithm (boolean 0 or 1) [From 02 -- Units: UNITLESS Size:2 Digits:0 Signed:U Scalar:1] [Jims comp:{EMMNone
AIF_FuelRateFuelling / rail[APFLRTAP] Fuel Rate algorithm as determined by the alpha determination algorithm [From 02 -- Units: UNITLESS Size:2 Digits:0 Signed:U Scalar:1] [Jimskg/hr
Audit_TrailFuelling / railData space reserved in the ECM as a scratchpad for tools to record changes they have requested of the ECM. Reference CES14278 and GTIS requirements. The audit
CBL_Fuel_CmdFuelling / railFuel command after imposing combustion limits [From 02 -- Units: MG/STROKE Size:2 Digits:2 Signed:U Scalar:0.067934782] [Jims comp:{CBM}]mg/stroke
AIF_AlphaAAPTurboProtBoost / turbo / VGT[APAAPRSS] Alpha contribution from ambient air pressure logic of the alopha algoirthm (boolean 0 or 1) [From 02 -- Units: UNITLESS Size:2 Digits:2 SignNone
BPS_BoostEngagedBoost / turbo / VGTHook identifying that Boost Power is actively engaged.None
BVC_s_LowBoostVoltageBoost / turbo / VGTlow boost voltage indicatorNone
Boost_Power_Request_SwitchBoost / turbo / VGTDebounced value of the Boost Power Request Switch.None
Boost_PressureBoost / turbo / VGTGage value of linearized and filtered Charge Press.kPa_G
CBL_EGR_Frac_CmdEGREGR fraction command passed to Charge Manager from Combustion Manager [From 02 -- Units: UNITLESS Size:2 Digits:3 Signed:U Scalar:0.00012207] [Jims coNone
CBR_Base_Chi_EGR_Frac_CmdEGREGR Fraction derived from chi_base [From 02 -- Units: UNITLESS Size:2 Digits:3 Signed:U Scalar:0.00012207] [Jims comp:{CBM}]None
CBR_EGR_Frac_RefEGREGR fraction reference, unlimited and uncompensated [From 02 -- Units: UNITLESS Size:2 Digits:3 Signed:U Scalar:0.00012207] [Jims comp:{CBM}]None
CBR_EGR_OffEGREGR is off by EMM permission or user overrideNone
C_APC_hp_NegRateTblEGRPressure rate limit tbl for decreasing accumulator pressure commands (>12.5 bar/sec).
C_DPF_Lamp_User_SelectableDPF / DOC / regenThis is a required parameterwhich indicates to the tool whether the DPF Lamp feature is available for selection by the tool.None
C_J39_Eng_BackPress_Soot_AxisDPF / DOC / regenX-Axis for C_J39_Eng_BackPress_Torque_Tbl. The input for this axis is V_SFP_mg_Soot_Load_Comb .
C_J39_PT_Regen_Force_Switch_Port_IDDPF / DOC / regenPort on which J39_PT_Regen_Force_Switch in the Cab 1 Message should be received.None
C_J39_PT_Regen_Force_Switch_TimeoutDPF / DOC / regenTimeout for J39_PT_Regen_Force_Switch.mSec
C_J39_PT_Regen_Inhibit_Switch_Port_IDDPF / DOC / regenPort on which J39_PT_Regen_Inhibit_Switch in the Cab 1 Message should be received.None
Auxiliary_Discrete_Input_1SCR / DEF / NOxAuxiliary Discrete Input 1 SwitchNone
CBO_bsNOxSCR / DEF / NOxCBR_NOx_Target_Ref adjusted for off-nominal conditions [From 02 -- Units: G/HP*HR Size:2 Digits:3 Signed:U Scalar:0.000244140625] [Jims comp:{CBM}]g/HP*hr
CBR_NOx_Target_RefSCR / DEF / NOxNOx target reference [From 02 -- Units: G/HP*HR Size:2 Digits:3 Signed:U Scalar:0.000488281] [Jims comp:{CBM}]g/HP*hr
C_ABS_Rmt_Throttle_Def_GovSCR / DEF / NOxThis parameter determines what is the default governor when remote throttle is active and T_SwitchableGovernorEnable is disabled. This would eliminate the need
C_APC_s_LppDiscreteOutputEnableSCR / DEF / NOxLift Pump discrete output enable 1 = Enable (discrete output), 0 = Disable (PWM output)HEX
AIF_AlphaGovernorSpeed / cruise / idle[APGVAP] result of On Governor logic (boolean 0 or 1) [From 02 -- Units: UNITLESS Size:2 Digits:0 Signed:U Scalar:1] [Jims comp:{EMM}]None
AIP_PTO_Var_Switch_Ovrd_ValSpeed / cruise / idleUser override value for PTO_Variable_SwitchNone
APP_On_IdleSpeed / cruise / idleIndicates whether or not the Accelerator is in the Idle position. Value is determined by either idle validation switches or Secondary_Accel_Pedal_Pos, dependinNone
AP_Low_Idle_SwitchSpeed / cruise / idleSwitch signal which indicates whether the accelerator pedal low idle switch is opened or closed. 0x00 Accelerator pedal not in low idle condition 0x01 AccelNone
Accelerator_Governor_SwitchSpeed / cruise / idleDebounced value of Accelerator Governor Switch physical input. When TRUE, this input causes Selected_Governor to toggle from "ABS" to "ABT" or vice versa depeNone
CAGT_Block_Fault_CodesFault codes / deratesArray of fault codes to be blocked. Fault codes can be found in CES14602 specification. Size of this array and hence the maximum number of faults that can be bl
CFTR_Block_Lamp_Fault_CodesFault codes / deratesContains the fault codes for which lamps are to be blocked. Fault codes can be found in CES14602 specification. Size of this array and hence the maximum number
CFTR_Fault_2_Lamp_MapFault codes / deratesA one dimensional array whose index is the same as error_index. It stores the lamp to light for each error. This design supports up to 8 lamps. 0000 0000 00
CFTR_Fault_Count_TableFault codes / deratesThis array contains the current fault count for each fault that is currently active in the system. The fault count for each error is incremented each time the
CFTR_Fault_Status_Mismatch_CtrFault codes / deratesThis indicates that how many times there was mismatch in the CFTR_Fault_Status_Table.Every error in the CFTR_ErrorIndexTable is searched in the ECM_Active_ErrorNone
AIP_WIF_Sensor_VoltageSensors / calibrationanalog voltage for water in fuel sensor inputV
APC_v_DslPrsSensorSensors / calibrationDiesel Rail Pressure Sensor Voltage (ref to 5V)V
APP2_Sensor_Supply_VoltageSensors / calibrationSecondary Accelerator Sensor supply voltage detected by the ECM.V
APP2_Sensor_VoltageSensors / calibrationSensor input voltage detected by the ECM for Secondary Accelerator.V
Accel_Position_Sensor_VoltsSensors / calibrationsensor voltage detected by the ECM.V

Sample of named calibration parameters with their Cummins descriptions. The full ECFG lists every parameter with ITN address, data type, scaling, limits and units.

Buy & download
Loading checkout…
Custom file service on your .xcal: DTC / full delete, extra HP, VGT delete