MY ACCOUNT / MY FILES →Cummins BBK 63.21.0.5 ECFG — ISF2.8 CM2250 tuning definition
Cummins BBK 63.21.0.5 ECFG — the ECFG definition file (Cummins DAMOS equivalent) for ISF2.8 (Foton (China)) on the CM22xx ECM: 14,389 named parameters for Calterm / WinOLS tuning — torque, fuelling, boost/VGT, EGR, DPF, SCR/DEF, speed limiter and fault-code tables. Build ID 207239, created 2018-02-02. Instant download after PayPal checkout.
FormatECFG — Engineering Tool Config File (XML)Product ID
BBKSoftware version63.21.0.5ModuleCM22xxECU platformCM2250 / CM2220 (2010-2016)EngineISF2.8Application / marketFoton (China)ProgramMR-Foton - ISF 3.8 - CM2220_PV - V63.21.00.05_01Build ID207239Creation date2018-02-02Copyright year2018Parameters14,389 named parameters (<parameter> records)Interface level4.5.4.2First prod cfg file version2003.1.1.0Module part number9999999Boot loader range2.0.0.7 → 2.0.0.11Byte orderBigEndianIndex table address0x00042000Price$200 · instant download after PayPal checkoutHeader CRCFEB2File size9.7 MBArchive copies1 copy heldFormatECFG XML (Engineering Tool Config File) · opens in Cummins Calterm; converts to WinOLS map pack / A2L on request<Engineering_Tool_Config_File version="63.21.0.5" crc="FEB2">
<compatibility_header>
<calibration_version>63.21.0.5</calibration_version>
<module_name>CM22xx</module_name>
<product_id>BBK</product_id>
<file_descriptor>Core-II Software Copyright 2018 Cummins Inc. - Cummins Confidential - MR-Foton - ISF 3.8 - CM2220_PV - V63.21.00.05_01 - Build ID - 207239</file_descriptor>
What is inside this ECFG
14,389 parameters — 1,538 tables / axes. Counts by area (a parameter can sit in more than one):
696Torque / power
765Fuelling / rail
479Boost / turbo / VGT
611EGR
94DPF / DOC / regen
1,221SCR / DEF / NOx
802Speed / cruise / idle
1,083Fault codes / derates
638Sensors / calibration
| Parameter | Area | Description | Units |
|---|---|---|---|
| ACA_Torque | Torque / power | Torque consumed by all ACAs. | N_m |
| ACA_Torque_Max | Torque / power | Torque value that all ACA can consume at most. | N_m |
| AECD_Trq_Drt_Ramp_Rate | Torque / power | emission manager aecd torqure ramp rate | s |
| ATLCKT_Torque_Request | Torque / power | The dynamic high request submitted by the anti theft lockout algorithm | N_m |
| Actual_Eng_Ind_Perc_Trq_Hi_Res | Torque / power | Parameter is used for broadcasting the high resolution portion of torque that goes with Actual_Eng_Indicated_Perc_Trq on J1939. | % |
| AH_Fuel_Derate_Latch | Fuelling / rail | [AHFLDRLA] Indicates turbo overspeed protection fuel derate [From 02 -- Units: UNITLESS Size:2 Digits:0 Signed:U Scalar:1] [Jims comp:{EMM}] | None |
| AIF_AlphaFuelRate | Fuelling / rail | Alpha request from fuel rate section of the Alpha algorithm (boolean 0 or 1) | None |
| AIF_FuelRate | Fuelling / rail | Fuel Rate algorithm as determined by the alpha determination algorithm. | kg/hr |
| Audit_Trail | Fuelling / rail | Data space reserved in the ECM as a scratchpad for tools to record changes they have requested of the ECM. Reference CES14278 and GTIS requirements. | |
| CBC_Trq2FuelCallList | Fuelling / rail | This array contains all the addresses (pointers) of Torque2Fuel service functions that need to be exercised by the combustion manager base. The array is filled | None |
| AIF_AlphaAAPTurboProt | Boost / turbo / VGT | Alpha contribution from ambient air pressure logic of the alpha algoirthm (boolean 0 or 1) | None |
| AIP_Charge_Tmptr_Override_Value | Boost / turbo / VGT | Charge_Tmptr override value when T_AIP_CHT_User_Override is set.. | Deg_C |
| BPS_BoostEngaged | Boost / turbo / VGT | Hook identifying that Boost Power is actively engaged. | None |
| BVC_s_LowBoostVoltage | Boost / turbo / VGT | low boost voltage indicator | None |
| Boost_Power_Request_Switch | Boost / turbo / VGT | Debounced value of the Boost Power Request Switch. | None |
| AIP_EGRDeltaPress_Override_Val | EGR | EGR Delta Press user override value when T_AIP_EGRDeltaPress_Ovrd_En is set. | kPa |
| AIP_EGROrificeTmptr2_Ovrd_Val | EGR | EGR Orifice Temperature user override value when T_AIP_EGROrificeTmptr2_Ovrd_En is set. | Deg_C |
| AIP_EGROrificeTmptr_Ovrd_Val | EGR | EGR Orifice Temperature user override value when T_AIP_EGROrificeTmptr_Ovrd_En is set. | Deg_C |
| CBL_EGR_Frac_Cmd | EGR | EGR fraction command passed to Charge Manager from Combustion Manager Base | None |
| CBL_EGR_Frac_Cmd_Enable | EGR | Enable for EGR Fraction Command Processing in Charge Manager Base | None |
| C_CBR_Regen_EL | DPF / DOC / regen | Force chi.el to this value upon regen | g/HP*hr |
| C_CHL_Surge_Margin_Limit_DeSoot | DPF / DOC / regen | Surge Margin Derate Limit for DeSoot mode | % |
| C_DLC_Prevent_Regen_TSC1_Addr | DPF / DOC / regen | List of addresses of TSC1 controlling devices for which stationary regen will be prohibited and LSI max limit will be lowered. All unused elements shall be fil | |
| C_DPF_Lamp_User_Selectable | DPF / DOC / regen | This is a required parameterwhich indicates to the tool whether the DPF Lamp feature is available for selection by the tool. | None |
| C_EXM_Allow_NMRegen_In_Felix | DPF / DOC / regen | A cal to allow Non mission Regen in Felix for industry when C_EXM_Regen_Industrial_En is true. | None |
| ACA_Urea_Level_Status | SCR / DEF / NOx | Indicate that urea tank level status. 0 - Normal, 1 - Too low, 2 - Too high, 3 - Override | None |
| AC_Discrete_Output | SCR / DEF / NOx | Parameter indicates the status of AC Driver 1- AC driver is turned ON 0 - AC driver is turned OFF | None |
| CBM_Dosing_Prohibit_EGR | SCR / DEF / NOx | Prohibits EGR Control when In-cylinder dosing is active | None |
| CBR_Dosing_CylCutoutMask | SCR / DEF / NOx | Bit mapped mask indicating what cylinders are cutout for in-cylinder dosing. Bit 0=cut out cylinder 1, bit 1=cut out cylinder 2 etc. When the corresponding bit | HEX |
| CBR_InCylDosing_Fuel | SCR / DEF / NOx | In Cylinder dosing Fuel | mg/stroke |
| AFW_Idle_Speed | Speed / cruise / idle | The idle speed calculated by the Alternator Failure warning feature | RPM |
| AIF_AlphaGovernor | Speed / cruise / idle | result of On Governor logic (boolean 0 or 1) | None |
| APP_On_Idle | Speed / cruise / idle | Indicates whether or not the Accelerator is in the Idle position. Value is determined by either idle validation switches or Secondary_Accel_Pedal_Pos, dependin | None |
| AP_Low_Idle_Switch | Speed / cruise / idle | Switch signal which indicates whether the accelerator pedal low idle switch is opened or closed. 0x00 Accelerator pedal not in low idle condition 0x01 Accel | None |
| Accelerator_Governor_Switch | Speed / cruise / idle | Debounced value of Accelerator Governor Switch physical input. When TRUE, this input causes Selected_Governor to toggle from "ABS" to "ABT" or vice versa depe | None |
| AIF_AlphaAltDerate_Timer | Fault codes / derates | semaphore used to latch AFC events that occur between alpha executions | s |
| CAC_OBD_Tmptr_Thd | Fault codes / derates | output of CAC OBD temperature threshold look up table. | Deg_C |
| CAGT_Block_Fault_Codes | Fault codes / derates | Array of fault codes to be blocked. Fault codes can be found in CES14602 specification. Size of this array and hence the maximum number of faults that can be bl | |
| CAGT_ENG_OBDAD_Data_Reset_Ptr | Fault codes / derates | funtion pointer to service OBDAD_Data_Reset of OBD-Administrator | None |
| CAGT_FreezeActFaultCodesFlag | Fault codes / derates | If it is TRUE, it freezes the active fault codes, and if it is FALSE, active fault codes are processed normal. | None |
| AC_Pressure | Sensors / calibration | The linearized and filtered analog air conditioner head pressure gage value. | kPa_G |
| AC_Pressure_Learned | Sensors / calibration | Status indicating AC pressure sensor is in range. | None |
| AC_Pressure_No_High_OR_Low_Flts | Sensors / calibration | Status indicating there are no AC Pressure High or Low Error faults. TRUE - If both AC Pressure High and Low Error faults are not there FALSE if either AC Pre | None |
| AC_Pressure_Not_High | Sensors / calibration | Status indicating AC Pressure is not higher than the threshold for AC to switch On TRUE - If AC Pressure is less than the threshold FALSE - If AC Pressure is | None |
| AC_Pressure_Not_Low | Sensors / calibration | Status indicating AC Pressure is not Lower than the threshold for AC to switch On TRUE - If AC Pressure is greater than the threshold FALSE - If AC Pressure i | None |
Sample of named calibration parameters with their Cummins descriptions. The full ECFG lists every parameter with ITN address, data type, scaling, limits and units.
Other BBK versions (12)
41.23.0.12ECFG · CM2250 · 2015-10-1353.26.0.2ECFG · CM2250 · 2009-10-1953.26.0.5ECFG · CM2250 · 2010-01-1163.21.0.1ECFG · CM2250 · 2009-09-1463.21.0.3ECFG · CM2250 · 2010-02-0163.21.0.5ECFG · CM2250 · 2011-08-2563.26.0.0ECFG · CM2250 · 2010-03-0563.26.0.1ECFG · CM2250 · 2010-06-0263.26.0.1ECFG · CM2250 · 2010-06-0263.26.0.4ECFG · CM2250 · 2011-11-2872.20.70.0ECFG · CM2250 · 2016-04-2972.20.70.1ECFG · CM2250 · 2017-01-27