ECFG Superstore › BDV › 25.43.92.28
MY ACCOUNT / MY FILES →

Cummins BDV 25.43.92.28 ECFG — Midrange industrial CM2250 tuning definition

Cummins BDV 25.43.92.28 ECFG — the ECFG definition file (Cummins DAMOS equivalent) for Midrange industrial (Midrange on-highway) on the CM22xx ECM: 19,400 named parameters for Calterm / WinOLS tuning — torque, fuelling, boost/VGT, EGR, DPF, SCR/DEF, speed limiter and fault-code tables. Build ID —, created 2016-01-10. Instant download after PayPal checkout.

FormatECFG — Engineering Tool Config File (XML)Product IDBDVSoftware version25.43.92.28ModuleCM22xxECU platformCM2250 / CM2220 (2010-2016)EngineMidrange industrialApplication / marketMidrange on-highwayEmissionsEuro VProgramMR-DaBai-Euro5-BDV-C31-CM2220C_V25.43.92.28Build ID—Creation date2016-01-10Copyright year2016Parameters19,400 named parameters (<parameter> records)Interface level4.5.6.0First prod cfg file version2003.1.1.0Module part number9999999Boot loader range2.0.0.7 → 2.0.1.2Byte orderBigEndianIndex table address0x00042000Price$200 · instant download after PayPal checkoutHeader CRCB34AFile size13.0 MBArchive copies1 copy heldFormatECFG XML (Engineering Tool Config File) · opens in Cummins Calterm; converts to WinOLS map pack / A2L on request
<Engineering_Tool_Config_File version="25.43.92.28" crc="B34A"> <compatibility_header> <calibration_version>25.43.92.28</calibration_version> <module_name>CM22xx</module_name> <product_id>BDV</product_id> <file_descriptor>Core-II Software Copyright 2016 Cummins Inc. - Cummins Confidential - MR-DaBai-Euro5-BDV-C31-CM2220C_V25.43.92.28</file_descriptor>

What is inside this ECFG

19,400 parameters — 2,012 tables / axes. Counts by area (a parameter can sit in more than one):

847Torque / power
893Fuelling / rail
544Boost / turbo / VGT
748EGR
208DPF / DOC / regen
2,219SCR / DEF / NOx
1,004Speed / cruise / idle
856Fault codes / derates
794Sensors / calibration
ParameterAreaDescriptionUnits
ACA_TorqueTorque / powerTorque consumed by all ACAs.N_m
ACA_Torque_MaxTorque / powerTorque value that all ACA can consume at most.N_m
ATLCKT_Torque_RequestTorque / powerThe dynamic high request submitted by the anti theft lockout algorithmN_m
Actual_Eng_Ind_Perc_Trq_Hi_ResTorque / powerParameter is used for broadcasting the high resolution portion of torque that goes with Actual_Eng_Indicated_Perc_Trq on J1939.%
Actual_Eng_Indicated_Perc_TrqTorque / powerParameter is used for broadcasting Actual Engine Percent Torque on the datalink%
AH_Fuel_Derate_LatchFuelling / rail[AHFLDRLA] Indicates turbo overspeed protection fuel derate [From 02 -- Units: UNITLESS Size:2 Digits:0 Signed:U Scalar:1] [Jims comp:{EMM}]None
AIF_AlphaFuelRateFuelling / railAlpha request from fuel rate section of the Alpha algorithm (boolean 0 or 1)None
AIF_FuelRateFuelling / railFuel Rate algorithm as determined by the alpha determination algorithm.kg/hr
Audit_TrailFuelling / railData space reserved in the ECM as a scratchpad for tools to record changes they have requested of the ECM. Reference CES14278 and GTIS requirements.
CBC_Trq2FuelCallListFuelling / railThis array contains all the addresses (pointers) of Torque2Fuel service functions that need to be exercised by the combustion manager base. The array is filled None
AIF_AlphaAAPTurboProtBoost / turbo / VGTAlpha contribution from ambient air pressure logic of the alpha algoirthm (boolean 0 or 1)None
AIP_ChargePress_Override_ValueBoost / turbo / VGTCharge Pressure override valuekPa
AIP_Charge_Tmptr_Override_ValueBoost / turbo / VGTCharge_Tmptr override value when T_AIP_CHT_User_Override is set..Deg_C
BPS_BoostEngagedBoost / turbo / VGTHook identifying that Boost Power is actively engaged.None
BVC_s_LowBoostVoltageBoost / turbo / VGTlow boost voltage indicatorNone
AIP_EGRDeltaPress_Override_ValEGREGR Delta Press user override value when T_AIP_EGRDeltaPress_Ovrd_En is set.kPa
AIP_EGROrificePress_Ovrd_ValEGREGR Orifice Pressure override valuekPa_A
AIP_EGROrificeTmptr2_Ovrd_ValEGREGR Orifice Temperature user override value when T_AIP_EGROrificeTmptr2_Ovrd_En is set.Deg_C
AIP_EGROrificeTmptr_Ovrd_ValEGREGR Orifice Temperature user override value when T_AIP_EGROrificeTmptr_Ovrd_En is set.Deg_C
B6_EAC_EGR_Valve_CmdEGREGR valve position command from staged EGR/Assist output%
C_AIM_FT_SCR_Regen_EnblDPF / DOC / regenEnable for SCR Regen FTIS.None
C_AIM_FT_SCR_Regen_UserSelectDPF / DOC / regenIndicates to the tool whether the SCR Regen feature is available for selectionNone
C_AIM_tm_FT_SCR_RegenDPF / DOC / regenTime allowed for tool initiated SCR Regen.s
C_AIM_tm_FT_SCR_Regen_MaxDPF / DOC / regenOverall time allowed for tool initiated SCR Regen that includes HC purge and Engine Speed Ramp down to Idle time (C_AIM_tm_FT_SCR_Regen + C_EXM_SCRRegen_TResp_s
C_ATR_trc_SCR_TM2_DPFOutHiThdDPF / DOC / regenHysteresis high threshold for the DPF Out tmptr disabling SCR moderate TMDeg_C
ACA_Urea_Level_StatusSCR / DEF / NOxIndicate that urea tank level status. 0 - Normal, 1 - Too low, 2 - Too high, 3 - OverrideNone
AC_Discrete_OutputSCR / DEF / NOxParameter indicates the status of AC Driver 1- AC driver is turned ON 0 - AC driver is turned OFFNone
CBM_Dosing_Prohibit_EGRSCR / DEF / NOxProhibits EGR Control when In-cylinder dosing is activeNone
CBM_NOx_Out_Rate_UnlimitedSCR / DEF / NOxEngine out NOx flow rate before rate limiter.g/hr
CBR_Dosing_CylCutoutMaskSCR / DEF / NOxBit mapped mask indicating what cylinders are cutout for in-cylinder dosing. Bit 0=cut out cylinder 1, bit 1=cut out cylinder 2 etc. When the corresponding bit HEX
AFW_Idle_SpeedSpeed / cruise / idleThe idle speed calculated by the Alternator Failure warning featureRPM
AIF_AlphaGovernorSpeed / cruise / idleresult of On Governor logic (boolean 0 or 1)None
APP_On_IdleSpeed / cruise / idleIndicates whether or not the Accelerator is in the Idle position. Value is determined by either idle validation switches or Secondary_Accel_Pedal_Pos, dependinNone
AP_Low_Idle_SwitchSpeed / cruise / idleSwitch signal which indicates whether the accelerator pedal low idle switch is opened or closed. 0x00 Accelerator pedal not in low idle condition 0x01 AccelNone
Accelerator_Governor_SwitchSpeed / cruise / idleDebounced value of Accelerator Governor Switch physical input. When TRUE, this input causes Selected_Governor to toggle from "ABS" to "ABT" or vice versa depeNone
AIF_AlphaAltDerate_TimerFault codes / deratessemaphore used to latch AFC events that occur between alpha executionss
CAGT_Block_Fault_CodesFault codes / deratesArray of fault codes to be blocked. Fault codes can be found in CES14602 specification. Size of this array and hence the maximum number of faults that can be bl
CAGT_ENG_OBDAD_Data_Reset_PtrFault codes / deratesfuntion pointer to service OBDAD_Data_Reset of OBD-AdministratorNone
CAGT_FreezeActFaultCodesFlagFault codes / deratesIf it is TRUE, it freezes the active fault codes, and if it is FALSE, active fault codes are processed normal.None
CBM_Permit_FSO_DiagnosisFault codes / deratesPermit FSO Diagnosis IndicatorNone
AC_PressureSensors / calibrationThe linearized and filtered analog air conditioner head pressure gage value.kPa
AC_Pressure_Error_CountsSensors / calibrationelapsed AC Pressure error count durationNone
AC_Pressure_LearnedSensors / calibrationStatus indicating AC pressure sensor is in range.None
AC_Pressure_No_High_OR_Low_FltsSensors / calibrationStatus indicating there are no AC Pressure High or Low Error faults. TRUE - If both AC Pressure High and Low Error faults are not there FALSE if either AC PreNone
AC_Pressure_Not_HighSensors / calibrationStatus indicating AC Pressure is not higher than the threshold for AC to switch On TRUE - If AC Pressure is less than the threshold FALSE - If AC Pressure is None

Sample of named calibration parameters with their Cummins descriptions. The full ECFG lists every parameter with ITN address, data type, scaling, limits and units.

Other BDV versions (1)

21.43.0.28ECFG · CM2250 · 2012-01-17
Buy & download
Loading checkout…
Custom file service on your .xcal: DTC / full delete, extra HP, VGT delete