ECFG Superstore › BGK › 50.70.70.0
MY ACCOUNT / MY FILES →

Cummins BGK 50.70.70.0 ECFG — Midrange industrial CM2350 tuning definition

Cummins BGK 50.70.70.0 ECFG — the ECFG definition file (Cummins DAMOS equivalent) for Midrange industrial (Midrange on-highway) on the CM23xx ECM: 23,728 named parameters for Calterm / WinOLS tuning — torque, fuelling, boost/VGT, EGR, DPF, SCR/DEF, speed limiter and fault-code tables. Build ID —, created 2015-03-09. Instant download after PayPal checkout.

FormatECFG — Engineering Tool Config File (XML)Product IDBGKSoftware version50.70.70.0ModuleCM23xxECU platformCM2350A / CM2350B (2013-2020)EngineMidrange industrialApplication / marketMidrange on-highwayModel year2015EmissionsChina VIProgramMR-CHN-Pele-MY15-CM2350-C31-V50.70.70.00Build ID—Creation date2015-03-09Copyright year2015Parameters23,728 named parameters (<parameter> records)Interface level4.6.0.0First prod cfg file version2003.1.1.0Module part number9999999Boot loader range2.3.0.6 → 2.3.0.9Byte orderBigEndianIndex table address0x00042000Price$100 · instant download after PayPal checkoutHeader CRC4724File size15.6 MBArchive copies1 copy heldFormatECFG XML (Engineering Tool Config File) · opens in Cummins Calterm; converts to WinOLS map pack / A2L on request
<Engineering_Tool_Config_File version="50.70.70.0" crc="4724"> <compatibility_header> <calibration_version>50.70.70.0</calibration_version> <module_name>CM23xx</module_name> <product_id>BGK</product_id> <file_descriptor>Core-II Software Copyright 2015 Cummins Inc. - Cummins Confidential - MR-CHN-Pele-MY15-CM2350-C31-V50.70.70.00</file_descriptor>

What is inside this ECFG

23,728 parameters — 2,179 tables / axes. Counts by area (a parameter can sit in more than one):

893Torque / power
967Fuelling / rail
589Boost / turbo / VGT
580EGR
1,390DPF / DOC / regen
2,494SCR / DEF / NOx
899Speed / cruise / idle
1,491Fault codes / derates
856Sensors / calibration
ParameterAreaDescriptionUnits
ACA_TorqueTorque / powerTorque consumed by all ACAs.N_m
ACA_Torque_MaxTorque / powerTorque value that all ACA can consume at most.N_m
Actual_Eng_Ind_Perc_Trq_Hi_ResTorque / powerParameter is used for broadcasting the high resolution portion of torque that goes with Actual_Eng_Indicated_Perc_Trq on J1939.%
Actual_Eng_Indicated_Perc_TrqTorque / powerParameter is used for broadcasting Actual Engine Percent Torque on the datalink%
Actual_Max_Avail_Eng_Perc_TrqTorque / powerParameter is used for broadcasting Actual Maximum Available Engine - Percent Torque (J1939 SPN 3357) through datalink. It is the maximum amount of torque that t%
AH_Fuel_Derate_LatchFuelling / rail[AHFLDRLA] Indicates turbo overspeed protection fuel derate [From 02 -- Units: UNITLESS Size:2 Digits:0 Signed:U Scalar:1] [Jims comp:{EMM}]None
AIC_q_TargetFuelArrayFuelling / railFueling array of the current pressure bucket
AIF_AlphaFuelRateFuelling / railAlpha request from fuel rate section of the Alpha algorithm (boolean 0 or 1)None
AIF_FuelRateFuelling / railFuel Rate algorithm as determined by the alpha determination algorithm.kg/hr
APC_ti_HiPrsFuelDurationFuelling / railUsed to verify fueling continuously exceeds a minimum threshold before enabling high pressure diagnostic up/down counters.s
AIF_AlphaAAPTurboProtBoost / turbo / VGTAlpha contribution from ambient air pressure logic of the alpha algoirthm (boolean 0 or 1)None
AIP_ChargePress_Override_ValueBoost / turbo / VGTCharge Pressure override valuekPa
AIP_Charge_Tmptr_Override_ValueBoost / turbo / VGTCharge_Tmptr override value when T_AIP_CHT_User_Override is set..Deg_C
BPS_BoostEngagedBoost / turbo / VGTHook identifying that Boost Power is actively engaged.None
BSM_ChargePress_Hi_EnabledBoost / turbo / VGTFlag for charge high pressure monitor enabled in BSMNone
AIP_EGROrificeTmptr_Ovrd_ValEGREGR Orifice Temperature user override value when T_AIP_EGROrificeTmptr_Ovrd_En is set.Deg_C
CBL_EGR_Frac_CmdEGREGR fraction command passed to Charge Manager from Combustion Manager BaseNone
CBL_EGR_Frac_Cmd_EnableEGREnable for EGR Fraction Command Processing in Charge Manager BaseNone
CBM_Dosing_Prohibit_EGREGRProhibits EGR Control when In-cylinder dosing is activeNone
CBO_EGR_Frac_CTLimitEGRThis value is TRUE when EGR Fraction Reference is being limited due to Coolant TemperatureNone
C_AIM_DOC_In_DualPullupEnblDPF / DOC / regenFlag enabling the dual pullup for the thermistorNone
C_AIM_DOC_Out_DualPullupEnblDPF / DOC / regenFlag enabling the dual pullup for the thermistorNone
C_AIM_DPF_DeltaP_SlowAIPEnblDPF / DOC / regenCal is used to enable the DeltaP slow AIPNone
C_AIM_DPF_Lamp_IDDPF / DOC / regenDPF Lamp ID(1 = STOP, 2 = WARNING, 3 = MAINTENANCE,4,5,6 ... unmapped)None
C_AIM_DPF_OutP_Sensor_PresentDPF / DOC / regenFlag indicating if the system contains a gage pressure sensor at the outlet of the DPF.None
AC_Discrete_OutputSCR / DEF / NOxParameter indicates the status of AC Driver 1- AC driver is turned ON 0 - AC driver is turned OFFNone
AIF_AlphaSCRSCR / DEF / NOxAlpha request from SCR Bed Temp section of the Alpha algorithm (boolean 0 or 1)None
APC_ti_LPrsCrankClearErrSCR / DEF / NOxTimer to clear a fuel pressure low cranking fault condition exists.s
CBM_NOx_Humidity_CorrSCR / DEF / NOxNOx humidity correction factorNone
CBM_NOx_Out_PPMSCR / DEF / NOxEnigne out virtual nox value in ppmPPM
AFW_Idle_SpeedSpeed / cruise / idleThe idle speed calculated by the Alternator Failure warning featureRPM
AIF_AlphaGovernorSpeed / cruise / idleresult of On Governor logic (boolean 0 or 1)None
APP_On_IdleSpeed / cruise / idleIndicates whether or not the Accelerator is in the Idle position. Value is determined by either idle validation switches or Secondary_Accel_Pedal_Pos, dependinNone
AP_Low_Idle_SwitchSpeed / cruise / idleSwitch signal which indicates whether the accelerator pedal low idle switch is opened or closed. 0x00 Accelerator pedal not in low idle condition 0x01 AccelNone
Accelerator_Governor_SwitchSpeed / cruise / idleDebounced value of Accelerator Governor Switch physical input. When TRUE, this input causes Selected_Governor to toggle from "ABS" to "ABT" or vice versa depeNone
ADD_ct_LatchOffFault1Fault codes / deratesdiagnostic counters for FSR latch off fault bitscounts
ADD_ct_LatchOffFault2Fault codes / deratesdiagnostic counters for FSR latch off fault bitscounts
ADD_ct_LatchOffFault3Fault codes / deratesdiagnostic counters for FSR latch off fault bitscounts
ADD_ct_LatchOffFault4Fault codes / deratesdiagnostic counters for FSR latch off fault bitscounts
ADD_ct_LatchOffFault5Fault codes / deratesdiagnostic counters for FSR latch off fault bitscounts
AC_PressureSensors / calibrationThe linearized and filtered analog air conditioner head pressure gage value.kPa
AC_Pressure_Error_CountsSensors / calibrationelapsed AC Pressure error count durationNone
AC_Pressure_LearnedSensors / calibrationStatus indicating AC pressure sensor is in range.None
AC_Pressure_No_High_OR_Low_FltsSensors / calibrationStatus indicating there are no AC Pressure High or Low Error faults. TRUE - If both AC Pressure High and Low Error faults are not there FALSE if either AC PreNone
AC_Pressure_Not_HighSensors / calibrationStatus indicating AC Pressure is not higher than the threshold for AC to switch On TRUE - If AC Pressure is less than the threshold FALSE - If AC Pressure is None

Sample of named calibration parameters with their Cummins descriptions. The full ECFG lists every parameter with ITN address, data type, scaling, limits and units.

Buy & download
Loading checkout…
Custom file service on your .xcal: DTC / full delete, extra HP, VGT delete