ECFG Superstore › BJA › 7.1.0.24
MY ACCOUNT / MY FILES →

Cummins BJA 7.1.0.24 ECFG — Natural gas HD CM2880 tuning definition

Cummins BJA 7.1.0.24 ECFG — the ECFG definition file (Cummins DAMOS equivalent) for Natural gas HD (Heavy duty on-highway) on the CM28xx ECM: 22,459 named parameters for Calterm / WinOLS tuning — torque, fuelling, boost/VGT, EGR, DPF, SCR/DEF, speed limiter and fault-code tables. Build ID 222623, created 2019-03-01. Instant download after PayPal checkout.

FormatECFG — Engineering Tool Config File (XML)Product IDBJASoftware version7.1.0.24ModuleCM28xxECU platformCM2880A natural gas + small boreEngineNatural gas HDApplication / marketHeavy duty on-highwayEmissionsEPA13ProgramHD-Class1-NS5-IAT-C31.00.00.00-CM2880E-7.01.01.24Build ID222623Creation date2019-03-01Copyright year2019Parameters22,459 named parameters (<parameter> records)Interface level4.6.0.0First prod cfg file version2003.1.1.0Module part number9999999Boot loader range2.8.9.0 → 2.8.9.0Byte orderBigEndianIndex table address0x00042000Price$200 · instant download after PayPal checkoutHeader CRC242AFile size15.1 MBArchive copies3 copies heldFormatECFG XML (Engineering Tool Config File) · opens in Cummins Calterm; converts to WinOLS map pack / A2L on request
<Engineering_Tool_Config_File version="7.1.0.24" crc="242A"> <compatibility_header> <calibration_version>7.1.0.24</calibration_version> <module_name>CM28xx</module_name> <product_id>BJA</product_id> <file_descriptor>Core-II Software Copyright 2019 Cummins Inc. - Cummins Confidential - HD-Class1-NS5-IAT-C31.00.00.00-CM2880E-7.01.01.24 - Build ID - 222623</file_descriptor>

What is inside this ECFG

22,459 parameters — 2,272 tables / axes. Counts by area (a parameter can sit in more than one):

943Torque / power
1,126Fuelling / rail
589Boost / turbo / VGT
398EGR
211DPF / DOC / regen
2,573SCR / DEF / NOx
1,045Speed / cruise / idle
1,176Fault codes / derates
897Sensors / calibration
ParameterAreaDescriptionUnits
ACA_TorqueTorque / powerTorque consumed by all ACAs.N_m
ACA_Torque_MaxTorque / powerTorque value that all ACA can consume at most.N_m
ATLCKT_Torque_RequestTorque / powerThe dynamic high request submitted by the anti theft lockout algorithmN_m
Actual_Eng_Ind_Perc_Trq_Hi_ResTorque / powerParameter is used for broadcasting the high resolution portion of torque that goes with Actual_Eng_Indicated_Perc_Trq on J1939.%
Actual_Eng_Indicated_Perc_TrqTorque / powerParameter is used for broadcasting Actual Engine Percent Torque on the datalink%
AH_Fuel_Derate_LatchFuelling / rail[AHFLDRLA] Indicates turbo overspeed protection fuel derate [From 02 -- Units: UNITLESS Size:2 Digits:0 Signed:U Scalar:1] [Jims comp:{EMM}]None
AIC_ct_LowFuelCvrgFuelling / railThis is the count that indicates the number of cells (Pressure/Fuel points) covered for each cylinder in the low Fueling Coverage Map
AIC_q_MeasFuelingFuelling / railThe actual fueling commanded by IFC during an AES or IFM test data collection.mg/stroke
AIC_q_TargetFuelArrayFuelling / railFueling array of the current pressure bucket
AIC_s_FuelingRegionFuelling / railThe fueling region associated with the commanded total fueling: 0 = NO_FUELING 1 = LOW_FUELING 2 = INTERPOLATION 3 = MID_FUELING 4 = HIGH_FUNone
AIF_AlphaAAPTurboProtBoost / turbo / VGTAlpha contribution from ambient air pressure logic of the alpha algoirthm (boolean 0 or 1)None
AIP_ChargePress_Override_ValueBoost / turbo / VGTCharge Pressure override valuekPa
AIP_Charge_Tmptr_Override_ValueBoost / turbo / VGTCharge_Tmptr override value when T_AIP_CHT_User_Override is set..Deg_C
BPS_BoostEngagedBoost / turbo / VGTHook identifying that Boost Power is actively engaged.None
BVC_s_LowBoostVoltageBoost / turbo / VGTlow boost voltage indicatorNone
AIP_EGROrificeTmptr_Ovrd_ValEGREGR Orifice Temperature user override value when T_AIP_EGROrificeTmptr_Ovrd_En is set.Deg_C
B6_EAC_EGR_Valve_CmdEGREGR valve position command from staged EGR/Assist output%
CBL_EGR_Frac_CmdEGREGR fraction command passed to Charge Manager from Combustion Manager BaseNone
CBL_EGR_Frac_Cmd_EnableEGREnable for EGR Fraction Command Processing in Charge Manager BaseNone
CBM_Dosing_Prohibit_EGREGRProhibits EGR Control when In-cylinder dosing is activeNone
C_AIM_FT_SCR_Regen_EnblDPF / DOC / regenEnable for SCR Regen FTIS.None
C_AIM_FT_SCR_Regen_UserSelectDPF / DOC / regenIndicates to the tool whether the SCR Regen feature is available for selectionNone
C_AIM_tm_FT_SCR_RegenDPF / DOC / regenTime allowed for tool initiated SCR Regen.s
C_AIM_tm_FT_SCR_Regen_MaxDPF / DOC / regenOverall time allowed for tool initiated SCR Regen that includes HC purge and Engine Speed Ramp down to Idle time (C_AIM_tm_FT_SCR_Regen + C_EXM_SCRRegen_TResp_s
C_ATD_FT_SCRRegen_History_EnblDPF / DOC / regenEnable SCR Regen History Record.None
ACA_Urea_Level_StatusSCR / DEF / NOxIndicate that urea tank level status. 0 - Normal, 1 - Too low, 2 - Too high, 3 - OverrideNone
AC_Discrete_OutputSCR / DEF / NOxParameter indicates the status of AC Driver 1- AC driver is turned ON 0 - AC driver is turned OFFNone
AIF_AlphaSCRSCR / DEF / NOxAlpha request from SCR Bed Temp section of the Alpha algorithm (boolean 0 or 1)None
APC_ti_LPrsCrankClearErrSCR / DEF / NOxTimer to clear a fuel pressure low cranking fault condition exists.s
CBM_NOx_Humidity_CorrSCR / DEF / NOxNOx humidity correction factorNone
AFW_Idle_SpeedSpeed / cruise / idleThe idle speed calculated by the Alternator Failure warning featureRPM
AIF_AlphaGovernorSpeed / cruise / idleresult of On Governor logic (boolean 0 or 1)None
APP_On_IdleSpeed / cruise / idleIndicates whether or not the Accelerator is in the Idle position. Value is determined by either idle validation switches or Secondary_Accel_Pedal_Pos, dependinNone
AP_Low_Idle_SwitchSpeed / cruise / idleSwitch signal which indicates whether the accelerator pedal low idle switch is opened or closed. 0x00 Accelerator pedal not in low idle condition 0x01 AccelNone
Accelerator_Governor_SwitchSpeed / cruise / idleDebounced value of Accelerator Governor Switch physical input. When TRUE, this input causes Selected_Governor to toggle from "ABS" to "ABT" or vice versa depeNone
ADD_ct_LatchOffFault1Fault codes / deratesdiagnostic counters for FSR latch off fault bitscounts
ADD_ct_LatchOffFault2Fault codes / deratesdiagnostic counters for FSR latch off fault bitscounts
ADD_ct_LatchOffFault3Fault codes / deratesdiagnostic counters for FSR latch off fault bitscounts
ADD_ct_LatchOffFault4Fault codes / deratesdiagnostic counters for FSR latch off fault bitscounts
ADD_ct_LatchOffFault5Fault codes / deratesdiagnostic counters for FSR latch off fault bitscounts
AC_PressureSensors / calibrationThe linearized and filtered analog air conditioner head pressure gage value.kPa
AC_Pressure_Error_CountsSensors / calibrationelapsed AC Pressure error count durationNone
AC_Pressure_LearnedSensors / calibrationStatus indicating AC pressure sensor is in range.None
AC_Pressure_No_High_OR_Low_FltsSensors / calibrationStatus indicating there are no AC Pressure High or Low Error faults. TRUE - If both AC Pressure High and Low Error faults are not there FALSE if either AC PreNone
AC_Pressure_Not_HighSensors / calibrationStatus indicating AC Pressure is not higher than the threshold for AC to switch On TRUE - If AC Pressure is less than the threshold FALSE - If AC Pressure is None

Sample of named calibration parameters with their Cummins descriptions. The full ECFG lists every parameter with ITN address, data type, scaling, limits and units.

Buy & download
Loading checkout…
Custom file service on your .xcal: DTC / full delete, extra HP, VGT delete