ECFG Superstore › ABC › 14.0.0.2
MY ACCOUNT / MY FILES →Cummins ABC 14.0.0.2 ECFG — L9 / ISL9 CM850 tuning definition
Cummins ABC 14.0.0.2 ECFG — the ECFG definition file (Cummins DAMOS equivalent) for L9 / ISL9 (Europe) on the CM850 ECM: 7,604 named parameters for Calterm / WinOLS tuning — torque, fuelling, boost/VGT, EGR, DPF, SCR/DEF, speed limiter and fault-code tables. Build ID —, created 2005-06-13. Instant download after PayPal checkout.
FormatECFG — Engineering Tool Config File (XML)Product ID
ABCSoftware version14.0.0.2ModuleCM850ECU platformCM850 / CM870 Core-II (2003-2007)EngineL9 / ISL9Application / marketEuropeEmissionsEuro IVProgramCopy,061305-170610,Core II Phase 14.00.00.02 - GTIS4.5Build ID—Creation date2005-06-13Copyright year2005Parameters7,604 named parameters (<parameter> records)Interface level4.5.2.0First prod cfg file version2003.1.1.0Module part number3954430Boot loader range4.6.0.0 → 4.7.0.1Byte orderBigEndianIndex table address0x00510000Price$100 · instant download after PayPal checkoutHeader CRC266AFile size5.4 MBArchive copies63 copies heldFormatECFG XML (Engineering Tool Config File) · opens in Cummins Calterm; converts to WinOLS map pack / A2L on request<Engineering_Tool_Config_File version="14.0.0.2" crc="266A">
<compatibility_header>
<calibration_version>14.0.0.2</calibration_version>
<module_name>CM850</module_name>
<product_id>ABC</product_id>
<file_descriptor>Core-II Software Copyright 2005 Cummins Inc. - Cummins Confidential - Copy,061305-170610,Core II Phase 14.00.00.02 - GTIS4.5</file_descriptor>
What is inside this ECFG
7,604 parameters — 1,077 tables / axes. Counts by area (a parameter can sit in more than one):
420Torque / power
450Fuelling / rail
369Boost / turbo / VGT
276EGR
1DPF / DOC / regen
23SCR / DEF / NOx
554Speed / cruise / idle
320Fault codes / derates
544Sensors / calibration
| Parameter | Area | Description | Units |
|---|---|---|---|
| ACA_Torque | Torque / power | Torque consumed by all ACAs. | N_m |
| ACA_Torque_Max | Torque / power | Torque value that all ACA can consume at most. | N_m |
| Actual_Eng_Indicated_Perc_Trq | Torque / power | Parameter is used for broadcasting Actual Engine Percent Torque on the datalink | % |
| All_Powerdown_Data_Lost_Run | Torque / power | Flag indicating if engine should be run if All_Powerdown_Data_Lost_Error is TRU | HEX |
| Boost_Power_Request_Switch | Torque / power | Debounced value of the Boost Power Request Switch. | None |
| AH_Fuel_Derate_Latch | Fuelling / rail | [AHFLDRLA] Indicates turbo overspeed protection fuel derate [From 02 -- Units: UNITLESS Size:2 Digits:0 Signed:U Scalar:1] [Jims comp:{EMM}] | None |
| AIF_AlphaFuelRate | Fuelling / rail | Alpha request from fuel rate section of the Alpha algorithm (boolean 0 or 1) [From 02 -- Units: UNITLESS Size:2 Digits:0 Signed:U Scalar:1] [Jims comp:{EMM | None |
| AIF_FuelRate | Fuelling / rail | [APFLRTAP] Fuel Rate algorithm as determined by the alpha determination algorithm [From 02 -- Units: UNITLESS Size:2 Digits:0 Signed:U Scalar:1] [Jims | kg/hr |
| Audit_Trail | Fuelling / rail | Data space reserved in the ECM as a scratchpad for tools to record changes they have requested of the ECM. Reference CES14278 and GTIS requirements. The audit | |
| CBL_Fuel_Cmd | Fuelling / rail | Fuel command after imposing combustion limits [From 02 -- Units: MG/STROKE Size:2 Digits:2 Signed:U Scalar:0.067934782] [Jims comp:{CBM}] | mg/stroke |
| AIF_AlphaAAPTurboProt | Boost / turbo / VGT | [APAAPRSS] Alpha contribution from ambient air pressure logic of the alopha algoirthm (boolean 0 or 1) [From 02 -- Units: UNITLESS Size:2 Digits:2 Sign | None |
| BPS_BoostEngaged | Boost / turbo / VGT | Hook identifying that Boost Power is actively engaged. | None |
| BVC_s_LowBoostVoltage | Boost / turbo / VGT | low boost voltage indicator | None |
| Boost_Pressure | Boost / turbo / VGT | Gage value of linearized and filtered Charge Press. | kPa_G |
| CBO_Charge_Aggressiveness_Ref | Boost / turbo / VGT | Charge aggressive reference after off-nominal compensation [From 02 -- Units: UNITLESS Size:2 Digits:3 Signed:U Scalar:0.00012207] [Jims comp:{CBM}] | None |
| CBL_EGR_Frac_Cmd | EGR | EGR fraction command passed to Charge Manager from Combustion Manager [From 02 -- Units: UNITLESS Size:2 Digits:3 Signed:U Scalar:0.00012207] [Jims co | None |
| CBR_Base_Chi_EGR_Frac_Cmd | EGR | EGR Fraction derived from chi_base [From 02 -- Units: UNITLESS Size:2 Digits:3 Signed:U Scalar:0.00012207] [Jims comp:{CBM}] | None |
| CBR_EGR_Frac_Ref | EGR | EGR fraction reference, unlimited and uncompensated [From 02 -- Units: UNITLESS Size:2 Digits:3 Signed:U Scalar:0.00012207] [Jims comp:{CBM}] | None |
| CBR_EGR_Off | EGR | EGR is off by EMM permission or user override | None |
| CHH_EGR_System_Failure | EGR | True/False indicator of an EGR system failure | None |
| C_UFD_r_SumDpFltrConst | DPF / DOC / regen | Filter constant for the Sum Dp filters. | None |
| CBO_bsNOx | SCR / DEF / NOx | CBR_NOx_Target_Ref adjusted for off-nominal conditions [From 02 -- Units: G/HP*HR Size:2 Digits:3 Signed:U Scalar:0.000244140625] [Jims comp:{CBM}] | g/HP*hr |
| CBR_NOx_Target_Ref | SCR / DEF / NOx | NOx target reference [From 02 -- Units: G/HP*HR Size:2 Digits:3 Signed:U Scalar:0.000488281] [Jims comp:{CBM}] | g/HP*hr |
| C_APC_s_LppDiscreteOutputEnable | SCR / DEF / NOx | Lift Pump discrete output enable 1 = Enable (discrete output), 0 = Disable (PWM output) | HEX |
| C_CBO_fsNOx_Ratio_Table | SCR / DEF / NOx | output axis of fsNOx ratio table [From 02 -- Units: UNITLESS Size:2 Digits:4 Signed:U Scalar:0.00012207] [Jims comp:{CBM}] | |
| C_DIP_DiscreteCoolantLevelDelay | SCR / DEF / NOx | The delay before engine coolant detected switches affect the Coolant Level Low Error. | s |
| AFW_Idle_Speed | Speed / cruise / idle | The idle speed calculated by the Alternator Failure warning feature | RPM |
| AIF_AlphaGovernor | Speed / cruise / idle | [APGVAP] result of On Governor logic (boolean 0 or 1) [From 02 -- Units: UNITLESS Size:2 Digits:0 Signed:U Scalar:1] [Jims comp:{EMM}] | None |
| APP_On_Idle | Speed / cruise / idle | Indicates whether or not the Accelerator is in the Idle position. Value is determined by either idle validation switches or Secondary_Accel_Pedal_Pos, dependin | None |
| AP_Low_Idle_Switch | Speed / cruise / idle | Switch signal which indicates whether the accelerator pedal low idle switch is opened or closed. 0x00 Accelerator pedal not in low idle condition 0x01 Accel | None |
| Accelerator_Governor_Switch | Speed / cruise / idle | Debounced value of Accelerator Governor Switch physical input. When TRUE, this input causes Selected_Governor to toggle from "ABS" to "ABT" or vice versa depe | None |
| AMB_AirPressDefault | Fault codes / derates | Air_Press_Sensor global default value [From 02 -- Units: IN_HG Size:2 Digits:2 Signed:U Scalar:0.0159064138077] [Jims comp:{EMM}] | kPa |
| CFTR_Fault_2_Lamp_Map | Fault codes / derates | A one dimensional array whose index is the same as error_index. It stores the lamp to light for each error. This design supports up to 8 lamps. 0000 0000 00 | |
| CFTR_Fault_Count_Table | Fault codes / derates | This array contains the current fault count for each fault that is currently active in the system. The fault count for each error is incremented each time the | |
| CFTR_Fault_Status_Table | Fault codes / derates | This array contains the current error state for each fault that is currently active in the system. The index into this array is associated with a system error | |
| CFTR_J1939_Fault_Mapping_Table | Fault codes / derates | Structure that maps J1939 error conditions with Cummins error codes. | |
| AMB_AirPressSensorPriority | Sensors / calibration | Air_Pressure_Sensor mux override priority [From 02 -- Units: UNITLESS Size:1 Digits:0 Signed:U Scalar:1] [Jims comp:{EMM}] | None |
| APC_v_DslPrsSensor | Sensors / calibration | Diesel Rail Pressure Sensor Voltage (ref to 5V) | V |
| APP2_Sensor_Supply_Voltage | Sensors / calibration | Secondary Accelerator Sensor supply voltage detected by the ECM. | V |
| APP2_Sensor_Voltage | Sensors / calibration | Sensor input voltage detected by the ECM for Secondary Accelerator. | V |
| APP_Sensor_Supply_Volts | Sensors / calibration | sensor supply voltage for Accelerator pedal position sensor. | V |
Sample of named calibration parameters with their Cummins descriptions. The full ECFG lists every parameter with ITN address, data type, scaling, limits and units.
Other ABC versions (6)
31.0.4.3ECFG · CM2350 · 2012-01-1331.1.5.2ECFG · CM2350 · 2012-01-3031.1.5.2ECFG · CM2350 · 2012-01-3031.1.5.3ECFG · CM2350 · 2012-03-2699999999E2M · E2M legacy · 2004-01-0199999999E2M · E2M legacy · 2004-01-01
Buy & download
Loading checkout…