MY ACCOUNT / MY FILES →Cummins BCQ 33.17.3.0 ECFG — DAF / PACCAR ACM CM1881 tuning definition
Cummins BCQ 33.17.3.0 ECFG — the ECFG definition file (Cummins DAMOS equivalent) for DAF / PACCAR ACM (DAF Euro 6 aftertreatment) on the CM1881 ECM: 13,443 named parameters for Calterm / WinOLS tuning — torque, fuelling, boost/VGT, EGR, DPF, SCR/DEF, speed limiter and fault-code tables. Build ID 193635, created 2017-02-24. Instant download after PayPal checkout.
FormatECFG — Engineering Tool Config File (XML)Product ID
BCQSoftware version33.17.3.0ModuleCM1881ECU platformCM1881 aftertreatment / industrialEngineDAF / PACCAR ACMApplication / marketDAF Euro 6 aftertreatmentProgramDAF33170300_CM1881_33.00.03.06_r00Build ID193635Creation date2017-02-24Copyright year2017Parameters13,443 named parameters (<parameter> records)Interface level4.5.4.3First prod cfg file version2003.1.1.0Module part number9999999Boot loader range2.8.8.3 → 2.8.8.5Byte orderBigEndianIndex table address0x00042000Price$500 · instant download after PayPal checkoutHeader CRCFD58File size8.7 MBArchive copies2 copies heldFormatECFG XML (Engineering Tool Config File) · opens in Cummins Calterm; converts to WinOLS map pack / A2L on request<Engineering_Tool_Config_File version="33.17.3.0" crc="FD58">
<compatibility_header>
<calibration_version>33.17.3.0</calibration_version>
<module_name>CM1881</module_name>
<product_id>BCQ</product_id>
<file_descriptor>Core-II Software Copyright 2017 Cummins Inc. - Cummins Confidential - DAF33170300_CM1881_33.00.03.06_r00 - Build ID - 193635</file_descriptor>
What is inside this ECFG
13,443 parameters — 596 tables / axes. Counts by area (a parameter can sit in more than one):
119Torque / power
177Fuelling / rail
84Boost / turbo / VGT
32EGR
1,616DPF / DOC / regen
2,844SCR / DEF / NOx
51Speed / cruise / idle
1,129Fault codes / derates
436Sensors / calibration
| Parameter | Area | Description | Units |
|---|---|---|---|
| CBM_Torque_Fuel | Torque / power | Total Fueling per stroke | mg/stroke |
| C_AIM_pc_EPD_RI_Trq_Drt_Limit | Torque / power | This is the percent of total torque derate that can be applied to the Regen Inhibit EPD channel (silent derate). | % |
| C_ATA_FT_OperatingMode_Enbl | Torque / power | For mapping this parameter to FTIS AFT_Operating_Mode_Enable | None |
| C_ATA_FT_OperatingMode_UserSelect | Torque / power | For mapping this parameter to FTIS AFT_Operating_Mode_User_Selectable | None |
| C_ATM_EPD_SCR_TrqDerateEnbl | Torque / power | enables torque derate function | None |
| Audit_Trail | Fuelling / rail | Data space reserved in the ECM as a scratchpad for tools to record changes they have requested of the ECM. Reference CES14278 and GTIS requirements. | |
| CBM_FdbkTotalFuel | Fuelling / rail | Feedback Fuel from Fuel Manager. | mg/stroke |
| C_ATA_HC_TotalFuelingChk_Enbl | Fuelling / rail | Calibration to Enable Total Fueling value check during HC Dosing | None |
| C_ATA_TotalFuelingChk_Enbl | Fuelling / rail | Calibration to allow check for Total fueling | None |
| C_ATA_ct_TotalFuelingStdy_Thd | Fuelling / rail | Maximum time to wait for stability in fueling rate | counts |
| C_ATA_tm_NOxSenHtrPerfAvgThd | Boost / turbo / VGT | The window for the NOx Sensor Status byte change detection time | s |
| C_ATA_trc_BHD_Charge_Drop_Thd | Boost / turbo / VGT | Calibratible charge temperature drop threshold to detect the Block Heater | Deg_C |
| C_ATD_tm_DPF_OutPKeyOffAvgThd | Boost / turbo / VGT | The time over which average of OutP values is calculated during Key Off diagnostic | s |
| C_ATD_tm_DPF_dPKeyOffAvgThd | Boost / turbo / VGT | The time over which average of dP values is calculated during Key Off diagnostic | s |
| C_ATD_trc_DOCInEngRun_AvgThd | Boost / turbo / VGT | Max average temperature threshold for DOC-In Engine Running Rationality diagnostic below which the DOC_IN_IRL_ERR will be set | Deg_C |
| C_AIM_FT_Filter_DeGreening_Enbl | EGR | For map this parameter to AFT_Filter_DeGreening_Enable | None |
| C_AIM_FT_Filter_DeGreening_Ext_Enbl | EGR | For map this parameter to AFT_Filter_DeGreening_Extension_Enable | None |
| C_AIM_FT_Filter_DeGreening_Ext_UserSelect | EGR | For map this parameter to FTIS AFT_Filter_DeGreening_Extension_User_Selectable | None |
| C_AIM_FT_Filter_DeGreening_UserSelect | EGR | For map this parameter to FTIS AFT_Filter_DeGreening_User_Selectable | None |
| C_ATA_NOxIn_Degreen_Enbl | EGR | Flag for enabling the NOxGreen Filter check | None |
| C_AIM_DOC_In_DualPullupEnbl | DPF / DOC / regen | Flag enabling the dual pullup for the thermistor | None |
| C_AIM_DOC_Out_DualPullupEnbl | DPF / DOC / regen | Flag enabling the dual pullup for the thermistor | None |
| C_AIM_DPF_DeltaP_Aux_Enbl | DPF / DOC / regen | DPF delta pressure auxilary enable(Applicable For AUTOSAR only) | None |
| C_AIM_DPF_DeltaP_SlowAIPEnbl | DPF / DOC / regen | Cal is used to enable the DeltaP slow AIP | None |
| C_AIM_DPF_Lamp_ID | DPF / DOC / regen | DPF Lamp ID(1 = STOP, 2 = WARNING, 3 = MAINTENANCE,4,5,6 ... unmapped) | None |
| CXPS_J39_NOx_Self_Diag_Req_Ptr | SCR / DEF / NOx | Pointer to CXPS - J1939 Smart O2/NOx Sensor provided Service: CXPS_J1939_NOx_request_Self_Diagnosis ( uint8 ATO1_Trigger, uint8 ATI1_Trigger, uint8 ATO2_Trigge | None |
| C_AIM_FT_DEF_DosingProhibited_Enbl | SCR / DEF / NOx | Indicates to the tool whether the AFT DEF Dosing Prohibited is enabled or disabled. | None |
| C_AIM_FT_DEF_DosingProhibited_UserSelect | SCR / DEF / NOx | Indicates to the tool whether the AFT DEF Dosing Prohibited is available for selection by the tool or not. | None |
| C_AIM_FT_SCRInTmptr_Enbl | SCR / DEF / NOx | Enables or disables the SCR Catalyst Inlet Temperature Sensor FTIS | None |
| C_AIM_FT_SCRInTmptr_UserSelect | SCR / DEF / NOx | Determines if SCR Catalyst Inlet Temperature Sensor FTIS is tool-adjustable. | None |
| C_AIM_vl_Vehicle_Speed_Thd | Speed / cruise / idle | Threshold used to indicate whether vehicle is moving or not | km/hr |
| C_ATA_Idle_NOxIn_Hi | Speed / cruise / idle | High NOx In value threshold at Idle. | ppm |
| C_ATA_Idle_NOxIn_Lo | Speed / cruise / idle | Low NOx In value threshold at Idle. | ppm |
| C_ATA_OEM_EngineIdleSpeed | Speed / cruise / idle | Calibration for Engine Idle Speed | RPM |
| C_ATP_tm_AutoNMR_MaxExtIdle | Speed / cruise / idle | Max time duration for which the extended idle enable conditions should be true to determine that the vehicle is in an Extended Idle condition | s |
| CAGT_Block_Fault_Codes | Fault codes / derates | Array of fault codes to be blocked. Fault codes can be found in CES14602 specification. Size of this array and hence the maximum number of faults that can be bl | |
| CAGT_FreezeActFaultCodesFlag | Fault codes / derates | If it is TRUE, it freezes the active fault codes, and if it is FALSE, active fault codes are processed normal. | None |
| CFTR_Block_Lamp_Fault_Codes | Fault codes / derates | Contains the fault codes for which lamps are to be blocked. Fault codes can be found in CES14602 specification. Size of this array and hence the maximum number | |
| CFTR_Fault_2_Lamp_Map | Fault codes / derates | A one dimensional array whose index is the same as error_index. It stores the lamp to light for each error. This design supports up to 8 lamps. 0000 0000 00 | |
| CFTR_Fault_Count_Table | Fault codes / derates | This array contains the current fault count for each fault that is currently active in the system. The fault count for each error is incremented each time the | |
| Batt_Tmptr_Sensor_Volts | Sensors / calibration | Sensor voltage detected by the ECM | V |
| C_AIM_DPF_OutP_Sensor_Present | Sensors / calibration | Flag indicating if the system contains a gage pressure sensor at the outlet of the DPF. | None |
| C_ATA_FT_IntakeNOxSensor_Monitor_Enbl | Sensors / calibration | For mapping this parameter to FTIS AFT_Intake_NOx_Sensor_Monitor_Enable | None |
| C_ATA_FT_IntakeNOxSensor_Monitor_UserSelect | Sensors / calibration | For mapping this parameter to FTIS AFT_Intake_NOx_Sensor_Monitor_User_Selectable | None |
| C_ATA_HIM_DPSLE_Sensor_Err | Sensors / calibration | Bitmaps for delta P sensor errors | HEX |
Sample of named calibration parameters with their Cummins descriptions. The full ECFG lists every parameter with ITN address, data type, scaling, limits and units.