ECFG Superstore › Cummins fault codes › 11999

Cummins fault code11999 · Cylinder R5 Ignition Coil Primary

Cylinder R5 Ignition Coil Primary - Current Above Normal or Grounded Circuit

Fault code11999 Cummins fault code as shown in INSITE / CaltermSPN521364 · Cylinder R5 Ignition Coil PrimaryFMI6 Current above normal or grounded circuitOBD codenone (J1939 only)LampAmber WARNING lampCummins textCylinder R5 Ignition Coil Primary - Current Above Normal or Grounded CircuitFailure modeCurrent Above Normal or Grounded Circuit

What Cummins code 11999 means

The driver or input for Cylinder R5 Ignition Coil Primary sees more current than it should, which the ECM interprets as a short to ground: chafed insulation, a pinched harness, or a shorted coil / solenoid.

It lights the amber CHECK ENGINE (warning) lamp. The engine keeps running, but a torque or speed derate may apply depending on the calibration and on how long the fault stays active.

On a generic J1939 scan tool, or on the dash of a Freightliner, Kenworth, Peterbilt, International or Volvo chassis, the same fault is shown as SPN 521364 FMI 6 rather than as Cummins code 11999. Cummins INSITE and Calterm show the Cummins number, the SPN / FMI pair and the lamp together.

Fix the file: delete code 11999 from your calibration
from $150

Custom DTC delete, up to 30 codes, $150. Full DPF / EGR / SCR delete with all related codes and derates, $500. Upload your Calterm .xcal, tick the services, pay with PayPal, and the finished file comes back by email and WhatsApp.

Upload your .xcal →
ECFG definition files for your ECM
1,800 files

Cummins ECFG / E2M definitions for CM550, CM552, CM554, CM570, CM800, CM850, CM870, CM871 and more: the fault table, torque, fuelling, boost, EGR, DPF and SCR maps, ready for Calterm or WinOLS. Instant download.

Find your ECFG →

Other Cummins codes on SPN 521364 Cylinder R5 Ignition Coil Primary

2 other fault codes share this SPN; each one is a different failure mode (FMI) of the same component.

11997 FMI 411998 FMI 5

All codes grouped by SPN →

Related Cummins fault codes

11995 · SPN 521363 FMI 5Cylinder R4 Ignition Coil Primary11996 · SPN 521363 FMI 6Cylinder R4 Ignition Coil Primary11997 · SPN 521364 FMI 4Cylinder R5 Ignition Coil Primary11998 · SPN 521364 FMI 5Cylinder R5 Ignition Coil Primary12111 · SPN 521365 FMI 4Cylinder R6 Ignition Coil Primary12112 · SPN 521365 FMI 5Cylinder R6 Ignition Coil Primary – Current Below Normal or12113 · SPN 521365 FMI 6Cylinder R6 Ignition Coil Primary12114 · SPN 521366 FMI 3Cylinder L1 Ignition Coil Secondary

J1939 failure mode identifiers (FMI)

FMI 6 is highlighted. The FMI is the second half of every J1939 fault and tells you how the component failed; the SPN tells you which component.

FMIMeaning (SAE J1939-73)
0Data valid but above normal operational range - most severe level
1Data valid but below normal operational range - most severe level
2Data erratic, intermittent or incorrect
3Voltage above normal, or shorted to high source
4Voltage below normal, or shorted to low source
5Current below normal or open circuit
6Current above normal or grounded circuit
7Mechanical system not responding or out of adjustment
8Abnormal frequency, pulse width or period
9Abnormal update rate
10Abnormal rate of change
11Root cause not known
12Bad intelligent device or component
13Out of calibration
14Special instructions
15Data valid but above normal operating range - least severe level
16Data valid but above normal operating range - moderately severe level
17Data valid but below normal operating range - least severe level
18Data valid but below normal operating range - moderately severe level
19Received network data in error
20Data drifted high
21Data drifted low
22Reserved for SAE assignment
23Reserved for SAE assignment
24Reserved for SAE assignment
25Reserved for SAE assignment
26Reserved for SAE assignment
27Reserved for SAE assignment
28Reserved for SAE assignment
29Reserved for SAE assignment
30Reserved for SAE assignment
31Condition exists

Questions about code 11999

What does Cummins fault code 11999 mean?

Cummins 11999 is "Cylinder R5 Ignition Coil Primary - Current Above Normal or Grounded Circuit". It maps to SPN 521364 FMI 6. The driver or input for Cylinder R5 Ignition Coil Primary sees more current than it should, which the ECM interprets as a short to ground: chafed insulation, a pinched harness, or a shorted coil / solenoid.

Which lamp does fault code 11999 turn on?

Amber WARNING lamp: It lights the amber CHECK ENGINE (warning) lamp. The engine keeps running, but a torque or speed derate may apply depending on the calibration and on how long the fault stays active.

How do I clear or permanently delete Cummins code 11999?

An active code goes inactive on its own once the condition is gone; the inactive record stays in the ECM fault history until it is cleared with Cummins INSITE (or a J1939 tool that supports the DM3 / DM11 clear). If the code keeps coming back because the part is gone, disconnected or not worth repairing, the lasting fix is to disable fault 11999 in the calibration: upload your .xcal to the ECFG Superstore file service, custom DTC delete from $150 (up to 30 codes), full DPF / EGR / SCR delete $500, and flash the returned file with Calterm or INSITE.

← All Cummins fault codes  ·  XCAL file service  ·  ECFG Superstore