Cummins fault code12126 · Cylinder L6 Ignition Coil Secondary

Cylinder L6 Ignition Coil Secondary - Current Below Normal or Open Circuit

Fault code12126 Cummins fault code as shown in INSITE / CaltermSPN521371 · Cylinder L6 Ignition Coil SecondaryFMI5 Current below normal or open circuitOBD codenone (J1939 only)LampAmber WARNING lampCummins textCylinder L6 Ignition Coil Secondary - Current Below Normal or Open CircuitFailure modeCurrent Below Normal or Open Circuit

What Cummins code 12126 means

The driver or input for Cylinder L6 Ignition Coil Secondary sees less current than it should, which the ECM interprets as an open circuit: a broken wire, an unplugged connector, or an open coil / solenoid.

It lights the amber CHECK ENGINE (warning) lamp. The engine keeps running, but a torque or speed derate may apply depending on the calibration and on how long the fault stays active.

On a generic J1939 scan tool, or on the dash of a Freightliner, Kenworth, Peterbilt, International or Volvo chassis, the same fault is shown as SPN 521371 FMI 5 rather than as Cummins code 12126. Cummins INSITE and Calterm show the Cummins number, the SPN / FMI pair and the lamp together.

Fix the file: delete code 12126 from your calibration
from $150

Custom DTC delete, up to 30 codes, $150. Full DPF / EGR / SCR delete with all related codes and derates, $500. Upload your Calterm .xcal, tick the services, pay with PayPal, and the finished file comes back by email and WhatsApp.

Upload your .xcal →
ECFG definition files for your ECM
1,800 files

Cummins ECFG / E2M definitions for CM550, CM552, CM554, CM570, CM800, CM850, CM870, CM871 and more: the fault table, torque, fuelling, boost, EGR, DPF and SCR maps, ready for Calterm or WinOLS. Instant download.

Find your ECFG →

Other Cummins codes on SPN 521371 Cylinder L6 Ignition Coil Secondary

2 other fault codes share this SPN; each one is a different failure mode (FMI) of the same component.

12125 FMI 312179 FMI 4

All codes grouped by SPN →

Related Cummins fault codes

12122 · SPN 521369 FMI 5Cylinder L4 Ignition Coil Secondary12123 · SPN 521370 FMI 3Cylinder L5 Ignition Coil Secondary12124 · SPN 521370 FMI 5Cylinder L5 Ignition Coil Secondary12125 · SPN 521371 FMI 3Cylinder L6 Ignition Coil Secondary12127 · SPN 521372 FMI 3Cylinder R1 Ignition Coil Secondary – Voltage Above Normal12128 · SPN 521372 FMI 5Cylinder R1 Ignition Coil Secondary – Current Below Normal12129 · SPN 521373 FMI 3Cylinder R2 Ignition Coil Secondary – Voltage Above Normal12131 · SPN 521373 FMI 5Cylinder R2 Ignition Coil Secondary – Current Below Normal

J1939 failure mode identifiers (FMI)

FMI 5 is highlighted. The FMI is the second half of every J1939 fault and tells you how the component failed; the SPN tells you which component.

FMIMeaning (SAE J1939-73)
0Data valid but above normal operational range - most severe level
1Data valid but below normal operational range - most severe level
2Data erratic, intermittent or incorrect
3Voltage above normal, or shorted to high source
4Voltage below normal, or shorted to low source
5Current below normal or open circuit
6Current above normal or grounded circuit
7Mechanical system not responding or out of adjustment
8Abnormal frequency, pulse width or period
9Abnormal update rate
10Abnormal rate of change
11Root cause not known
12Bad intelligent device or component
13Out of calibration
14Special instructions
15Data valid but above normal operating range - least severe level
16Data valid but above normal operating range - moderately severe level
17Data valid but below normal operating range - least severe level
18Data valid but below normal operating range - moderately severe level
19Received network data in error
20Data drifted high
21Data drifted low
22Reserved for SAE assignment
23Reserved for SAE assignment
24Reserved for SAE assignment
25Reserved for SAE assignment
26Reserved for SAE assignment
27Reserved for SAE assignment
28Reserved for SAE assignment
29Reserved for SAE assignment
30Reserved for SAE assignment
31Condition exists

Questions about code 12126

What does Cummins fault code 12126 mean?

Cummins 12126 is "Cylinder L6 Ignition Coil Secondary - Current Below Normal or Open Circuit". It maps to SPN 521371 FMI 5. The driver or input for Cylinder L6 Ignition Coil Secondary sees less current than it should, which the ECM interprets as an open circuit: a broken wire, an unplugged connector, or an open coil / solenoid.

Which lamp does fault code 12126 turn on?

Amber WARNING lamp: It lights the amber CHECK ENGINE (warning) lamp. The engine keeps running, but a torque or speed derate may apply depending on the calibration and on how long the fault stays active.

How do I clear or permanently delete Cummins code 12126?

An active code goes inactive on its own once the condition is gone; the inactive record stays in the ECM fault history until it is cleared with Cummins INSITE (or a J1939 tool that supports the DM3 / DM11 clear). If the code keeps coming back because the part is gone, disconnected or not worth repairing, the lasting fix is to disable fault 12126 in the calibration: upload your .xcal to the ECFG Superstore file service, custom DTC delete from $150 (up to 30 codes), full DPF / EGR / SCR delete $500, and flash the returned file with Calterm or INSITE.