ECFG Superstore › Cummins fault codes › 12416

Cummins fault code12416 · Aftertreatment 2 Diesel Exhaust Fluid Dosing Valve 1

Aftertreatment 2 Diesel Exhaust Fluid Dosing Valve 1 - Current Below Normal or Open Circuit

Fault code12416 Cummins fault code as shown in INSITE / CaltermSPN5974 · Aftertreatment 2 Diesel Exhaust Fluid Dosing Valve 1FMI5 Current below normal or open circuitOBD codenone (J1939 only)LampAmber WARNING lampCummins textAftertreatment 2 Diesel Exhaust Fluid Dosing Valve 1 - Current Below Normal or Open CircuitFailure modeCurrent Below Normal or Open Circuit

What Cummins code 12416 means

The driver or input for Aftertreatment 2 Diesel Exhaust Fluid Dosing Valve 1 sees less current than it should, which the ECM interprets as an open circuit: a broken wire, an unplugged connector, or an open coil / solenoid.

It lights the amber CHECK ENGINE (warning) lamp. The engine keeps running, but a torque or speed derate may apply depending on the calibration and on how long the fault stays active.

On a generic J1939 scan tool, or on the dash of a Freightliner, Kenworth, Peterbilt, International or Volvo chassis, the same fault is shown as SPN 5974 FMI 5 rather than as Cummins code 12416. Cummins INSITE and Calterm show the Cummins number, the SPN / FMI pair and the lamp together.

This is an emissions-system code. If the component it refers to has been removed or unplugged (DPF, EGR, SCR / DEF or NOx sensor delete) the code will keep returning and the derate with it, however many times it is cleared, because the diagnostic is still enabled in the calibration. The lasting fix in that case is to disable the fault in the .xcal itself.

Fix the file: delete code 12416 from your calibration
from $150

Custom DTC delete, up to 30 codes, $150. Full DPF / EGR / SCR delete with all related codes and derates, $500. Upload your Calterm .xcal, tick the services, pay with PayPal, and the finished file comes back by email and WhatsApp.

Upload your .xcal →
ECFG definition files for your ECM
1,800 files

Cummins ECFG / E2M definitions for CM550, CM552, CM554, CM570, CM800, CM850, CM870, CM871 and more: the fault table, torque, fuelling, boost, EGR, DPF and SCR maps, ready for Calterm or WinOLS. Instant download.

Find your ECFG →

Other Cummins codes on SPN 5974 Aftertreatment 2 Diesel Exhaust Fluid Dosing Valve 1

8 other fault codes share this SPN; each one is a different failure mode (FMI) of the same component.

4462 FMI 54463 FMI 74712 FMI 211147 FMI 311148 FMI 412219 FMI 1512373 FMI 1512454 FMI 3

All codes grouped by SPN →

Related Cummins fault codes

12412 · SPN 5973 FMI 3Aftertreatment 2 Diesel Exhaust Fluid Line Heater Relay 112413 · SPN 5973 FMI 4Aftertreatment 2 Diesel Exhaust Fluid Line Heater Relay 112414 · SPN 4427 FMI 4Aftertreatment 2 Diesel Exhaust Fluid Tank Temperature 112415 · SPN 4427 FMI 3Aftertreatment 2 Diesel Exhaust Fluid Tank Temperature 112417 · SPN 5971 FMI 3Aftertreatment 2 Diesel Exhaust Fluid Dosing Unit 1 Heater12418 · SPN 5971 FMI 4Aftertreatment 2 Diesel Exhaust Fluid Dosing Unit 1 Heater12419 · SPN 6587 FMI 4Aftertreatment 2 SCR Intake Pressure12421 · SPN 6587 FMI 3Aftertreatment 2 SCR Intake Pressure

J1939 failure mode identifiers (FMI)

FMI 5 is highlighted. The FMI is the second half of every J1939 fault and tells you how the component failed; the SPN tells you which component.

FMIMeaning (SAE J1939-73)
0Data valid but above normal operational range - most severe level
1Data valid but below normal operational range - most severe level
2Data erratic, intermittent or incorrect
3Voltage above normal, or shorted to high source
4Voltage below normal, or shorted to low source
5Current below normal or open circuit
6Current above normal or grounded circuit
7Mechanical system not responding or out of adjustment
8Abnormal frequency, pulse width or period
9Abnormal update rate
10Abnormal rate of change
11Root cause not known
12Bad intelligent device or component
13Out of calibration
14Special instructions
15Data valid but above normal operating range - least severe level
16Data valid but above normal operating range - moderately severe level
17Data valid but below normal operating range - least severe level
18Data valid but below normal operating range - moderately severe level
19Received network data in error
20Data drifted high
21Data drifted low
22Reserved for SAE assignment
23Reserved for SAE assignment
24Reserved for SAE assignment
25Reserved for SAE assignment
26Reserved for SAE assignment
27Reserved for SAE assignment
28Reserved for SAE assignment
29Reserved for SAE assignment
30Reserved for SAE assignment
31Condition exists

Questions about code 12416

What does Cummins fault code 12416 mean?

Cummins 12416 is "Aftertreatment 2 Diesel Exhaust Fluid Dosing Valve 1 - Current Below Normal or Open Circuit". It maps to SPN 5974 FMI 5. The driver or input for Aftertreatment 2 Diesel Exhaust Fluid Dosing Valve 1 sees less current than it should, which the ECM interprets as an open circuit: a broken wire, an unplugged connector, or an open coil / solenoid.

Which lamp does fault code 12416 turn on?

Amber WARNING lamp: It lights the amber CHECK ENGINE (warning) lamp. The engine keeps running, but a torque or speed derate may apply depending on the calibration and on how long the fault stays active.

How do I clear or permanently delete Cummins code 12416?

An active code goes inactive on its own once the condition is gone; the inactive record stays in the ECM fault history until it is cleared with Cummins INSITE (or a J1939 tool that supports the DM3 / DM11 clear). If the code keeps coming back because the part is gone, disconnected or not worth repairing, the lasting fix is to disable fault 12416 in the calibration: upload your .xcal to the ECFG Superstore file service, custom DTC delete from $150 (up to 30 codes), full DPF / EGR / SCR delete $500, and flash the returned file with Calterm or INSITE.