ECFG Superstore › Cummins fault codes › 1276

Cummins fault code1276 · Engine Cylinder 10 (B5) Knock Sensor Circuit

Engine Cylinder 10 (B5) Knock Sensor Circuit - Voltage Above Normal or Shorted to High Source

Fault code1276 Cummins fault code as shown in INSITE / CaltermSPN1361 · Engine Cylinder 10 (B5) KnockFMI3 Voltage above normal, or shorted to high sourceOBD codenone (J1939 only)LampAmber WARNING lampCummins textEngine Cylinder 10 (B5) Knock Sensor Circuit - Voltage Above Normal or Shorted to High SourceFailure modeVoltage Above Normal or Shorted to High Source

What Cummins code 1276 means

The signal wire for Engine Cylinder 10 (B5) Knock Sensor Circuit is sitting above the voltage window the ECM expects. In practice that is usually an open signal or return wire (the ECM pull-up takes the input high), a short to the 5 V supply or battery, or a failed sensor element.

It lights the amber CHECK ENGINE (warning) lamp. The engine keeps running, but a torque or speed derate may apply depending on the calibration and on how long the fault stays active.

On a generic J1939 scan tool, or on the dash of a Freightliner, Kenworth, Peterbilt, International or Volvo chassis, the same fault is shown as SPN 1361 FMI 3 rather than as Cummins code 1276. Cummins INSITE and Calterm show the Cummins number, the SPN / FMI pair and the lamp together.

Fix the file: delete code 1276 from your calibration
from $150

Custom DTC delete, up to 30 codes, $150. Full DPF / EGR / SCR delete with all related codes and derates, $500. Upload your Calterm .xcal, tick the services, pay with PayPal, and the finished file comes back by email and WhatsApp.

Upload your .xcal →
ECFG definition files for your ECM
1,800 files

Cummins ECFG / E2M definitions for CM550, CM552, CM554, CM570, CM800, CM850, CM870, CM871 and more: the fault table, torque, fuelling, boost, EGR, DPF and SCR maps, ready for Calterm or WinOLS. Instant download.

Find your ECFG →

Other Cummins codes on SPN 1361 Engine Cylinder 10 (B5) Knock

8 other fault codes share this SPN; each one is a different failure mode (FMI) of the same component.

1274 FMI 0 · P23451275 FMI 41727 FMI 32441 FMI 15 · P23452532 FMI 16 · P23453121 FMI 144821 FMI 315235 FMI 31

All codes grouped by SPN →

Related Cummins fault codes

1272 · SPN 1342 FMI 18Exhaust Gas Temperature Cylinder 201273 · SPN 1342 FMI 16Exhaust Gas Temperature Cylinder 201274 · SPN 1361 FMI 0Engine Cylinder 10 (B5) Knock1275 · SPN 1361 FMI 4Engine Cylinder 10 (B5) Knock Sensor Circuit1277 · SPN 1362 FMI 4Engine Cylinder 11 (A6) Knock Sensor Circuit1278 · SPN 1362 FMI 3Engine Cylinder 11 (A6) Knock Sensor Circuit1279 · SPN 1363 FMI 15Engine Cylinder 12 (B6) Knock1281 · SPN 1363 FMI 0Engine Cylinder 12 (B6) Knock

J1939 failure mode identifiers (FMI)

FMI 3 is highlighted. The FMI is the second half of every J1939 fault and tells you how the component failed; the SPN tells you which component.

FMIMeaning (SAE J1939-73)
0Data valid but above normal operational range - most severe level
1Data valid but below normal operational range - most severe level
2Data erratic, intermittent or incorrect
3Voltage above normal, or shorted to high source
4Voltage below normal, or shorted to low source
5Current below normal or open circuit
6Current above normal or grounded circuit
7Mechanical system not responding or out of adjustment
8Abnormal frequency, pulse width or period
9Abnormal update rate
10Abnormal rate of change
11Root cause not known
12Bad intelligent device or component
13Out of calibration
14Special instructions
15Data valid but above normal operating range - least severe level
16Data valid but above normal operating range - moderately severe level
17Data valid but below normal operating range - least severe level
18Data valid but below normal operating range - moderately severe level
19Received network data in error
20Data drifted high
21Data drifted low
22Reserved for SAE assignment
23Reserved for SAE assignment
24Reserved for SAE assignment
25Reserved for SAE assignment
26Reserved for SAE assignment
27Reserved for SAE assignment
28Reserved for SAE assignment
29Reserved for SAE assignment
30Reserved for SAE assignment
31Condition exists

Questions about code 1276

What does Cummins fault code 1276 mean?

Cummins 1276 is "Engine Cylinder 10 (B5) Knock Sensor Circuit - Voltage Above Normal or Shorted to High Source". It maps to SPN 1361 FMI 3. The signal wire for Engine Cylinder 10 (B5) Knock Sensor Circuit is sitting above the voltage window the ECM expects. In practice that is usually an open signal or return wire (the ECM pull-up takes the input high), a short to the 5 V supply or battery, or a

Which lamp does fault code 1276 turn on?

Amber WARNING lamp: It lights the amber CHECK ENGINE (warning) lamp. The engine keeps running, but a torque or speed derate may apply depending on the calibration and on how long the fault stays active.

How do I clear or permanently delete Cummins code 1276?

An active code goes inactive on its own once the condition is gone; the inactive record stays in the ECM fault history until it is cleared with Cummins INSITE (or a J1939 tool that supports the DM3 / DM11 clear). If the code keeps coming back because the part is gone, disconnected or not worth repairing, the lasting fix is to disable fault 1276 in the calibration: upload your .xcal to the ECFG Superstore file service, custom DTC delete from $150 (up to 30 codes), full DPF / EGR / SCR delete $500, and flash the returned file with Calterm or INSITE.

← All Cummins fault codes  ·  XCAL file service  ·  ECFG Superstore