Cummins fault code12972 · HVESP1 Module 16 Operational Status

HVESP1 Module 16 Operational Status - Received Network Data in Error

Fault code12972 Cummins fault code as shown in INSITE / CaltermSPN11108 · HVESP1 Module 16 Operational StatusFMI19 Received network data in errorOBD codenone (J1939 only)LampNo lampCummins textHVESP1 Module 16 Operational Status - Received Network Data in ErrorFailure modeReceived Network Data in Error

What Cummins code 12972 means

Another module on the datalink is sending the ECM a value for HVESP1 Module 16 Operational Status that is flagged as an error or is out of the valid range. The sensor may be fine; the fault points at the module that broadcasts the value or at the datalink wiring.

No dash lamp is attached to this code in the Cummins fault table. It is logged in the ECM and shows up in Cummins INSITE (or any J1939 tool reading DM1 / DM2), but on its own it does not light a lamp.

On a generic J1939 scan tool, or on the dash of a Freightliner, Kenworth, Peterbilt, International or Volvo chassis, the same fault is shown as SPN 11108 FMI 19 rather than as Cummins code 12972. Cummins INSITE and Calterm show the Cummins number, the SPN / FMI pair and the lamp together.

Fix the file: delete code 12972 from your calibration
from $150

Custom DTC delete, up to 30 codes, $150. Full DPF / EGR / SCR delete with all related codes and derates, $500. Upload your Calterm .xcal, tick the services, pay with PayPal, and the finished file comes back by email and WhatsApp.

Upload your .xcal →
ECFG definition files for your ECM
1,800 files

Cummins ECFG / E2M definitions for CM550, CM552, CM554, CM570, CM800, CM850, CM870, CM871 and more: the fault table, torque, fuelling, boost, EGR, DPF and SCR maps, ready for Calterm or WinOLS. Instant download.

Find your ECFG →

Other Cummins codes on SPN 11108 HVESP1 Module 16 Operational Status

10 other fault codes share this SPN; each one is a different failure mode (FMI) of the same component.

11488 FMI 912963 FMI 1412964 FMI 812965 FMI 1312966 FMI 212967 FMI 1112968 FMI 1212969 FMI 3112971 FMI 912973 FMI 5

All codes grouped by SPN →

Related Cummins fault codes

12967 · SPN 11108 FMI 11HVESP1 Module 16 Operational Status12968 · SPN 11108 FMI 12HVESP1 Module 16 Operational Status12969 · SPN 11108 FMI 31HVESP1 Module 16 Operational Status12971 · SPN 11108 FMI 9HVESP1 Module 16 Operational Status12973 · SPN 11108 FMI 5HVESP1 Module 16 Operational Status12974 · SPN 516106 FMI 19High Voltage Isometer Battery Voltage12975 · SPN 516107 FMI 19High Voltage Isometer Error Flags12976 · SPN 516108 FMI 19High Voltage Isometer Isolation Capacitances

J1939 failure mode identifiers (FMI)

FMI 19 is highlighted. The FMI is the second half of every J1939 fault and tells you how the component failed; the SPN tells you which component.

FMIMeaning (SAE J1939-73)
0Data valid but above normal operational range - most severe level
1Data valid but below normal operational range - most severe level
2Data erratic, intermittent or incorrect
3Voltage above normal, or shorted to high source
4Voltage below normal, or shorted to low source
5Current below normal or open circuit
6Current above normal or grounded circuit
7Mechanical system not responding or out of adjustment
8Abnormal frequency, pulse width or period
9Abnormal update rate
10Abnormal rate of change
11Root cause not known
12Bad intelligent device or component
13Out of calibration
14Special instructions
15Data valid but above normal operating range - least severe level
16Data valid but above normal operating range - moderately severe level
17Data valid but below normal operating range - least severe level
18Data valid but below normal operating range - moderately severe level
19Received network data in error
20Data drifted high
21Data drifted low
22Reserved for SAE assignment
23Reserved for SAE assignment
24Reserved for SAE assignment
25Reserved for SAE assignment
26Reserved for SAE assignment
27Reserved for SAE assignment
28Reserved for SAE assignment
29Reserved for SAE assignment
30Reserved for SAE assignment
31Condition exists

Questions about code 12972

What does Cummins fault code 12972 mean?

Cummins 12972 is "HVESP1 Module 16 Operational Status - Received Network Data in Error". It maps to SPN 11108 FMI 19. Another module on the datalink is sending the ECM a value for HVESP1 Module 16 Operational Status that is flagged as an error or is out of the valid range. The sensor may be fine; the fault points at the module that broadcasts the value or at the datalink

Which lamp does fault code 12972 turn on?

No lamp: No dash lamp is attached to this code in the Cummins fault table. It is logged in the ECM and shows up in Cummins INSITE (or any J1939 tool reading DM1 / DM2), but on its own it does not light a lamp.

How do I clear or permanently delete Cummins code 12972?

An active code goes inactive on its own once the condition is gone; the inactive record stays in the ECM fault history until it is cleared with Cummins INSITE (or a J1939 tool that supports the DM3 / DM11 clear). If the code keeps coming back because the part is gone, disconnected or not worth repairing, the lasting fix is to disable fault 12972 in the calibration: upload your .xcal to the ECFG Superstore file service, custom DTC delete from $150 (up to 30 codes), full DPF / EGR / SCR delete $500, and flash the returned file with Calterm or INSITE.