ECFG Superstore › Cummins fault codes › 13834

Cummins fault code13834 · Converter Rectifier IGBT-1 Healthy Status

Converter Rectifier IGBT-1 Healthy Status - Condition Exists

Fault code13834 Cummins fault code as shown in INSITE / CaltermSPN516248 · Converter Rectifier IGBT-1 Healthy StatusFMI31 Condition existsOBD codenone (J1939 only)LampRed STOP lampCummins textConverter Rectifier IGBT-1 Healthy Status - Condition ExistsFailure modeCondition Exists

What Cummins code 13834 means

This is not an electrical fault on a sensor. FMI 31 means the ECM has detected that the named condition for Converter Rectifier IGBT-1 Healthy Status is true. The fault code itself is the message; the fix is to find out why the ECM believes the condition exists.

It turns on the red STOP ENGINE lamp. Cummins classes this as a fault that can damage the engine or aftertreatment if ignored: stop as soon as it is safe to do so. Many calibrations also apply an engine-protection derate while the fault is active.

On a generic J1939 scan tool, or on the dash of a Freightliner, Kenworth, Peterbilt, International or Volvo chassis, the same fault is shown as SPN 516248 FMI 31 rather than as Cummins code 13834. Cummins INSITE and Calterm show the Cummins number, the SPN / FMI pair and the lamp together.

Fix the file: delete code 13834 from your calibration
from $150

Custom DTC delete, up to 30 codes, $150. Full DPF / EGR / SCR delete with all related codes and derates, $500. Upload your Calterm .xcal, tick the services, pay with PayPal, and the finished file comes back by email and WhatsApp.

Upload your .xcal →
ECFG definition files for your ECM
1,800 files

Cummins ECFG / E2M definitions for CM550, CM552, CM554, CM570, CM800, CM850, CM870, CM871 and more: the fault table, torque, fuelling, boost, EGR, DPF and SCR maps, ready for Calterm or WinOLS. Instant download.

Find your ECFG →

Other Cummins codes on SPN 516248 Converter Rectifier IGBT-1 Healthy Status

Code 13834 is the only Cummins fault code assigned to SPN 516248.

All codes grouped by SPN →

Related Cummins fault codes

13829 · SPN 516244 FMI 0Converter Filter capacitor 4 temperature13831 · SPN 516245 FMI 0Converter Filter capacitor 5 temperature13832 · SPN 516246 FMI 31Converter Input Earth Relay Healthy Status13833 · SPN 516247 FMI 31Converter Output Earth Relay Healthy Status13835 · SPN 516249 FMI 31Converter Rectifier IGBT-2 Healthy Status13836 · SPN 516250 FMI 31Converter Rectifier IGBT-3 Healthy Status13837 · SPN 516251 FMI 31Converter Rectifier IGBT-4 Healthy Status13838 · SPN 516252 FMI 31Converter Inverter IGBT-1 Healthy Status

J1939 failure mode identifiers (FMI)

FMI 31 is highlighted. The FMI is the second half of every J1939 fault and tells you how the component failed; the SPN tells you which component.

FMIMeaning (SAE J1939-73)
0Data valid but above normal operational range - most severe level
1Data valid but below normal operational range - most severe level
2Data erratic, intermittent or incorrect
3Voltage above normal, or shorted to high source
4Voltage below normal, or shorted to low source
5Current below normal or open circuit
6Current above normal or grounded circuit
7Mechanical system not responding or out of adjustment
8Abnormal frequency, pulse width or period
9Abnormal update rate
10Abnormal rate of change
11Root cause not known
12Bad intelligent device or component
13Out of calibration
14Special instructions
15Data valid but above normal operating range - least severe level
16Data valid but above normal operating range - moderately severe level
17Data valid but below normal operating range - least severe level
18Data valid but below normal operating range - moderately severe level
19Received network data in error
20Data drifted high
21Data drifted low
22Reserved for SAE assignment
23Reserved for SAE assignment
24Reserved for SAE assignment
25Reserved for SAE assignment
26Reserved for SAE assignment
27Reserved for SAE assignment
28Reserved for SAE assignment
29Reserved for SAE assignment
30Reserved for SAE assignment
31Condition exists

Questions about code 13834

What does Cummins fault code 13834 mean?

Cummins 13834 is "Converter Rectifier IGBT-1 Healthy Status - Condition Exists". It maps to SPN 516248 FMI 31. This is not an electrical fault on a sensor. FMI 31 means the ECM has detected that the named condition for Converter Rectifier IGBT-1 Healthy Status is true. The fault code itself is the message; the fix is to find out why the ECM believes the condition

Which lamp does fault code 13834 turn on?

Red STOP lamp: It turns on the red STOP ENGINE lamp. Cummins classes this as a fault that can damage the engine or aftertreatment if ignored: stop as soon as it is safe to do so. Many calibrations also apply an engine-protection derate while the fault is active.

How do I clear or permanently delete Cummins code 13834?

An active code goes inactive on its own once the condition is gone; the inactive record stays in the ECM fault history until it is cleared with Cummins INSITE (or a J1939 tool that supports the DM3 / DM11 clear). If the code keeps coming back because the part is gone, disconnected or not worth repairing, the lasting fix is to disable fault 13834 in the calibration: upload your .xcal to the ECFG Superstore file service, custom DTC delete from $150 (up to 30 codes), full DPF / EGR / SCR delete $500, and flash the returned file with Calterm or INSITE.

← All Cummins fault codes  ·  XCAL file service  ·  ECFG Superstore