Cummins fault code14794 · Air Bypass Valve

Air Bypass Valve - Out of Calibration

Fault code14794 Cummins fault code as shown in INSITE / CaltermSPN517126 · Air Bypass ValveFMI13 Out of calibrationOBD codenone (J1939 only)LampRed STOP lampCummins textAir Bypass Valve - Out of CalibrationFailure modeOut of Calibration

What Cummins code 14794 means

The calibration data stored for Air Bypass Valve does not match what the ECM measures or expects. This can be an adaptive value that has drifted outside limits, a component that was replaced without the matching learn procedure, or calibration data that is missing or corrupt.

It turns on the red STOP ENGINE lamp. Cummins classes this as a fault that can damage the engine or aftertreatment if ignored: stop as soon as it is safe to do so. Many calibrations also apply an engine-protection derate while the fault is active.

On a generic J1939 scan tool, or on the dash of a Freightliner, Kenworth, Peterbilt, International or Volvo chassis, the same fault is shown as SPN 517126 FMI 13 rather than as Cummins code 14794. Cummins INSITE and Calterm show the Cummins number, the SPN / FMI pair and the lamp together.

Fix the file: delete code 14794 from your calibration
from $150

Custom DTC delete, up to 30 codes, $150. Full DPF / EGR / SCR delete with all related codes and derates, $500. Upload your Calterm .xcal, tick the services, pay with PayPal, and the finished file comes back by email and WhatsApp.

Upload your .xcal →
ECFG definition files for your ECM
1,800 files

Cummins ECFG / E2M definitions for CM550, CM552, CM554, CM570, CM800, CM850, CM870, CM871 and more: the fault table, torque, fuelling, boost, EGR, DPF and SCR maps, ready for Calterm or WinOLS. Instant download.

Find your ECFG →

Other Cummins codes on SPN 517126 Air Bypass Valve

3 other fault codes share this SPN; each one is a different failure mode (FMI) of the same component.

14793 FMI 1215111 FMI 717526 FMI 12

All codes grouped by SPN →

Related Cummins fault codes

14789 · SPN 517092 FMI 7Hydrogen Proportional Valve14791 · SPN 517092 FMI 12Hydrogen Proportional Valve14792 · SPN 517124 FMI 31Multiple Hydrogen Sensors Failure14793 · SPN 517126 FMI 12Air Bypass Valve14795 · SPN 517127 FMI 0Stack Air Inlet Pressure14796 · SPN 517127 FMI 1Stack Air Inlet Pressure14797 · SPN 517128 FMI 0Stack Air Inlet Temperature14798 · SPN 517129 FMI 1Stack Cells

J1939 failure mode identifiers (FMI)

FMI 13 is highlighted. The FMI is the second half of every J1939 fault and tells you how the component failed; the SPN tells you which component.

FMIMeaning (SAE J1939-73)
0Data valid but above normal operational range - most severe level
1Data valid but below normal operational range - most severe level
2Data erratic, intermittent or incorrect
3Voltage above normal, or shorted to high source
4Voltage below normal, or shorted to low source
5Current below normal or open circuit
6Current above normal or grounded circuit
7Mechanical system not responding or out of adjustment
8Abnormal frequency, pulse width or period
9Abnormal update rate
10Abnormal rate of change
11Root cause not known
12Bad intelligent device or component
13Out of calibration
14Special instructions
15Data valid but above normal operating range - least severe level
16Data valid but above normal operating range - moderately severe level
17Data valid but below normal operating range - least severe level
18Data valid but below normal operating range - moderately severe level
19Received network data in error
20Data drifted high
21Data drifted low
22Reserved for SAE assignment
23Reserved for SAE assignment
24Reserved for SAE assignment
25Reserved for SAE assignment
26Reserved for SAE assignment
27Reserved for SAE assignment
28Reserved for SAE assignment
29Reserved for SAE assignment
30Reserved for SAE assignment
31Condition exists

Questions about code 14794

What does Cummins fault code 14794 mean?

Cummins 14794 is "Air Bypass Valve - Out of Calibration". It maps to SPN 517126 FMI 13. The calibration data stored for Air Bypass Valve does not match what the ECM measures or expects. This can be an adaptive value that has drifted outside limits, a component that was replaced without the matching learn procedure, or calibration data that is

Which lamp does fault code 14794 turn on?

Red STOP lamp: It turns on the red STOP ENGINE lamp. Cummins classes this as a fault that can damage the engine or aftertreatment if ignored: stop as soon as it is safe to do so. Many calibrations also apply an engine-protection derate while the fault is active.

How do I clear or permanently delete Cummins code 14794?

An active code goes inactive on its own once the condition is gone; the inactive record stays in the ECM fault history until it is cleared with Cummins INSITE (or a J1939 tool that supports the DM3 / DM11 clear). If the code keeps coming back because the part is gone, disconnected or not worth repairing, the lasting fix is to disable fault 14794 in the calibration: upload your .xcal to the ECFG Superstore file service, custom DTC delete from $150 (up to 30 codes), full DPF / EGR / SCR delete $500, and flash the returned file with Calterm or INSITE.

← All Cummins fault codes  ·  XCAL file service  ·  ECFG Superstore