ECFG Superstore › Cummins fault codes › 15342

Cummins fault code15342 · HVES1 Module Temperature 4

HVES1 Module Temperature 4 - Voltage Below Normal or Shorted to Low Source

Fault code15342 Cummins fault code as shown in INSITE / CaltermSPN9157 · HVES1 Module Temperature 4FMI4 Voltage below normal, or shorted to low sourceOBD codenone (J1939 only)LampAmber WARNING lampCummins textHVES1 Module Temperature 4 - Voltage Below Normal or Shorted to Low SourceFailure modeVoltage Below Normal or Shorted to Low Source

What Cummins code 15342 means

The signal wire for HVES1 Module Temperature 4 is sitting below the voltage window the ECM expects. In practice that is usually a short to ground, a short to the sensor return, a failed sensor, or a missing 5 V supply.

It lights the amber CHECK ENGINE (warning) lamp. The engine keeps running, but a torque or speed derate may apply depending on the calibration and on how long the fault stays active.

On a generic J1939 scan tool, or on the dash of a Freightliner, Kenworth, Peterbilt, International or Volvo chassis, the same fault is shown as SPN 9157 FMI 4 rather than as Cummins code 15342. Cummins INSITE and Calterm show the Cummins number, the SPN / FMI pair and the lamp together.

Fix the file: delete code 15342 from your calibration
from $150

Custom DTC delete, up to 30 codes, $150. Full DPF / EGR / SCR delete with all related codes and derates, $500. Upload your Calterm .xcal, tick the services, pay with PayPal, and the finished file comes back by email and WhatsApp.

Upload your .xcal →
ECFG definition files for your ECM
1,800 files

Cummins ECFG / E2M definitions for CM550, CM552, CM554, CM570, CM800, CM850, CM870, CM871 and more: the fault table, torque, fuelling, boost, EGR, DPF and SCR maps, ready for Calterm or WinOLS. Instant download.

Find your ECFG →

Other Cummins codes on SPN 9157 HVES1 Module Temperature 4

4 other fault codes share this SPN; each one is a different failure mode (FMI) of the same component.

12726 FMI 1312727 FMI 3112728 FMI 715322 FMI 3

All codes grouped by SPN →

Related Cummins fault codes

15337 · SPN 13016 FMI 3HVESP1 Status 1 CRC15338 · SPN 9154 FMI 4HVESP1 Module Temperature 115339 · SPN 9155 FMI 4HVES1 Module Temperature 215341 · SPN 9156 FMI 4HVES1 Module Temperature 315343 · SPN 9158 FMI 4HVES1 Module Temperature 515344 · SPN 9159 FMI 4HVES1 Module Temperature 615345 · SPN 9160 FMI 4HVES1 Module Temperature 715346 · SPN 9161 FMI 4HVES1 Module Temperature 8

J1939 failure mode identifiers (FMI)

FMI 4 is highlighted. The FMI is the second half of every J1939 fault and tells you how the component failed; the SPN tells you which component.

FMIMeaning (SAE J1939-73)
0Data valid but above normal operational range - most severe level
1Data valid but below normal operational range - most severe level
2Data erratic, intermittent or incorrect
3Voltage above normal, or shorted to high source
4Voltage below normal, or shorted to low source
5Current below normal or open circuit
6Current above normal or grounded circuit
7Mechanical system not responding or out of adjustment
8Abnormal frequency, pulse width or period
9Abnormal update rate
10Abnormal rate of change
11Root cause not known
12Bad intelligent device or component
13Out of calibration
14Special instructions
15Data valid but above normal operating range - least severe level
16Data valid but above normal operating range - moderately severe level
17Data valid but below normal operating range - least severe level
18Data valid but below normal operating range - moderately severe level
19Received network data in error
20Data drifted high
21Data drifted low
22Reserved for SAE assignment
23Reserved for SAE assignment
24Reserved for SAE assignment
25Reserved for SAE assignment
26Reserved for SAE assignment
27Reserved for SAE assignment
28Reserved for SAE assignment
29Reserved for SAE assignment
30Reserved for SAE assignment
31Condition exists

Questions about code 15342

What does Cummins fault code 15342 mean?

Cummins 15342 is "HVES1 Module Temperature 4 - Voltage Below Normal or Shorted to Low Source". It maps to SPN 9157 FMI 4. The signal wire for HVES1 Module Temperature 4 is sitting below the voltage window the ECM expects. In practice that is usually a short to ground, a short to the sensor return, a failed sensor, or a missing 5 V supply.

Which lamp does fault code 15342 turn on?

Amber WARNING lamp: It lights the amber CHECK ENGINE (warning) lamp. The engine keeps running, but a torque or speed derate may apply depending on the calibration and on how long the fault stays active.

How do I clear or permanently delete Cummins code 15342?

An active code goes inactive on its own once the condition is gone; the inactive record stays in the ECM fault history until it is cleared with Cummins INSITE (or a J1939 tool that supports the DM3 / DM11 clear). If the code keeps coming back because the part is gone, disconnected or not worth repairing, the lasting fix is to disable fault 15342 in the calibration: upload your .xcal to the ECFG Superstore file service, custom DTC delete from $150 (up to 30 codes), full DPF / EGR / SCR delete $500, and flash the returned file with Calterm or INSITE.

← All Cummins fault codes  ·  XCAL file service  ·  ECFG Superstore