Cummins fault code15477 · Converter Input Inductor Winding Temperature

Converter Input Inductor Winding Temperature - Data Valid But Above Normal Operating Range - Most Severe Level

Fault code15477 Cummins fault code as shown in INSITE / CaltermSPN516314 · Converter Input Inductor Winding TemperatureFMI0 Data valid but above normal operational range - most severe levelOBD codenone (J1939 only)LampRed STOP lampCummins textConverter Input Inductor Winding Temperature - Data Valid But Above Normal Operating Range - Most Severe LevelFailure modeData Valid But Above Normal Operating Range - Most Severe Level

What Cummins code 15477 means

The reading for Converter Input Inductor Winding Temperature is believed to be correct, but it has gone above the highest limit in the calibration. This is the most severe of the three "above range" levels (FMI 15, 16 and 0), so the ECM is reporting a real operating problem rather than a wiring fault.

It turns on the red STOP ENGINE lamp. Cummins classes this as a fault that can damage the engine or aftertreatment if ignored: stop as soon as it is safe to do so. Many calibrations also apply an engine-protection derate while the fault is active.

On a generic J1939 scan tool, or on the dash of a Freightliner, Kenworth, Peterbilt, International or Volvo chassis, the same fault is shown as SPN 516314 FMI 0 rather than as Cummins code 15477. Cummins INSITE and Calterm show the Cummins number, the SPN / FMI pair and the lamp together.

Fix the file: delete code 15477 from your calibration
from $150

Custom DTC delete, up to 30 codes, $150. Full DPF / EGR / SCR delete with all related codes and derates, $500. Upload your Calterm .xcal, tick the services, pay with PayPal, and the finished file comes back by email and WhatsApp.

Upload your .xcal →
ECFG definition files for your ECM
1,800 files

Cummins ECFG / E2M definitions for CM550, CM552, CM554, CM570, CM800, CM850, CM870, CM871 and more: the fault table, torque, fuelling, boost, EGR, DPF and SCR maps, ready for Calterm or WinOLS. Instant download.

Find your ECFG →

Other Cummins codes on SPN 516314 Converter Input Inductor Winding Temperature

2 other fault codes share this SPN; each one is a different failure mode (FMI) of the same component.

15478 FMI 515479 FMI 6

All codes grouped by SPN →

Related Cummins fault codes

15473 · SPN 516312 FMI 6Converter Output inductor V-Winding temperature15474 · SPN 516313 FMI 0Converter Output Inductor W-Winding Temperature15475 · SPN 516313 FMI 5Converter Output Inductor W-Winding Temperature15476 · SPN 516313 FMI 6Converter Output Inductor W-Winding Temperature15478 · SPN 516314 FMI 5Converter Input Inductor Winding Temperature15479 · SPN 516314 FMI 6Converter Input Inductor Winding Temperature15481 · SPN 516315 FMI 0Converter 3 Phase Transformer Winding Temperature15482 · SPN 516315 FMI 5Converter 3 Phase Transformer Winding Temperature

J1939 failure mode identifiers (FMI)

FMI 0 is highlighted. The FMI is the second half of every J1939 fault and tells you how the component failed; the SPN tells you which component.

FMIMeaning (SAE J1939-73)
0Data valid but above normal operational range - most severe level
1Data valid but below normal operational range - most severe level
2Data erratic, intermittent or incorrect
3Voltage above normal, or shorted to high source
4Voltage below normal, or shorted to low source
5Current below normal or open circuit
6Current above normal or grounded circuit
7Mechanical system not responding or out of adjustment
8Abnormal frequency, pulse width or period
9Abnormal update rate
10Abnormal rate of change
11Root cause not known
12Bad intelligent device or component
13Out of calibration
14Special instructions
15Data valid but above normal operating range - least severe level
16Data valid but above normal operating range - moderately severe level
17Data valid but below normal operating range - least severe level
18Data valid but below normal operating range - moderately severe level
19Received network data in error
20Data drifted high
21Data drifted low
22Reserved for SAE assignment
23Reserved for SAE assignment
24Reserved for SAE assignment
25Reserved for SAE assignment
26Reserved for SAE assignment
27Reserved for SAE assignment
28Reserved for SAE assignment
29Reserved for SAE assignment
30Reserved for SAE assignment
31Condition exists

Questions about code 15477

What does Cummins fault code 15477 mean?

Cummins 15477 is "Converter Input Inductor Winding Temperature - Data Valid But Above Normal Operating Range - Most Severe Level". It maps to SPN 516314 FMI 0. The reading for Converter Input Inductor Winding Temperature is believed to be correct, but it has gone above the highest limit in the calibration. This is the most severe of the three "above range" levels (FMI 15, 16 and 0), so the ECM is reporting a real

Which lamp does fault code 15477 turn on?

Red STOP lamp: It turns on the red STOP ENGINE lamp. Cummins classes this as a fault that can damage the engine or aftertreatment if ignored: stop as soon as it is safe to do so. Many calibrations also apply an engine-protection derate while the fault is active.

How do I clear or permanently delete Cummins code 15477?

An active code goes inactive on its own once the condition is gone; the inactive record stays in the ECM fault history until it is cleared with Cummins INSITE (or a J1939 tool that supports the DM3 / DM11 clear). If the code keeps coming back because the part is gone, disconnected or not worth repairing, the lasting fix is to disable fault 15477 in the calibration: upload your .xcal to the ECFG Superstore file service, custom DTC delete from $150 (up to 30 codes), full DPF / EGR / SCR delete $500, and flash the returned file with Calterm or INSITE.