ECFG Superstore › Cummins fault codes › 1568

Cummins fault code1568 · Injector Solenoid Driver Cylinder 15 Circuit

Injector Solenoid Driver Cylinder 15 Circuit - Current Above Normal or Grounded Circuit

Fault code1568 Cummins fault code as shown in INSITE / CaltermSPN665 · Injector Solenoid Driver Cylinder 15 CircuitFMI6 Current above normal or grounded circuitOBD codenone (J1939 only)LampAmber WARNING lampCummins textInjector Solenoid Driver Cylinder 15 Circuit - Current Above Normal or Grounded CircuitFailure modeCurrent Above Normal or Grounded Circuit

What Cummins code 1568 means

The driver or input for Injector Solenoid Driver Cylinder 15 Circuit sees more current than it should, which the ECM interprets as a short to ground: chafed insulation, a pinched harness, or a shorted coil / solenoid.

It lights the amber CHECK ENGINE (warning) lamp. The engine keeps running, but a torque or speed derate may apply depending on the calibration and on how long the fault stays active.

On a generic J1939 scan tool, or on the dash of a Freightliner, Kenworth, Peterbilt, International or Volvo chassis, the same fault is shown as SPN 665 FMI 6 rather than as Cummins code 1568. Cummins INSITE and Calterm show the Cummins number, the SPN / FMI pair and the lamp together.

Fix the file: delete code 1568 from your calibration
from $150

Custom DTC delete, up to 30 codes, $150. Full DPF / EGR / SCR delete with all related codes and derates, $500. Upload your Calterm .xcal, tick the services, pay with PayPal, and the finished file comes back by email and WhatsApp.

Upload your .xcal →
ECFG definition files for your ECM
1,800 files

Cummins ECFG / E2M definitions for CM550, CM552, CM554, CM570, CM800, CM850, CM870, CM871 and more: the fault table, torque, fuelling, boost, EGR, DPF and SCR maps, ready for Calterm or WinOLS. Instant download.

Find your ECFG →

Other Cummins codes on SPN 665 Injector Solenoid Driver Cylinder 15 Circuit

3 other fault codes share this SPN; each one is a different failure mode (FMI) of the same component.

1556 FMI 54652 FMI 136835 FMI 7

All codes grouped by SPN →

Related Cummins fault codes

1564 · SPN 661 FMI 6Injector Solenoid Driver Cylinder 11 Circuit1565 · SPN 662 FMI 6Injector Solenoid Driver Cylinder 12 Circuit1566 · SPN 663 FMI 6Injector Solenoid Driver Cylinder 13 Circuit1567 · SPN 664 FMI 6Injector Solenoid Driver Cylinder 14 Circuit1569 · SPN 666 FMI 6Injector Solenoid Driver Cylinder 16 Circuit1571 · SPN 668 FMI 6Injector Solenoid Driver Cylinder 18 Circuit1572 · SPN 1370 FMI 16Engine Cylinder 19 (A10) Knock1573 · SPN 520236 FMI 31GenSet Customer Defined Fault 1

J1939 failure mode identifiers (FMI)

FMI 6 is highlighted. The FMI is the second half of every J1939 fault and tells you how the component failed; the SPN tells you which component.

FMIMeaning (SAE J1939-73)
0Data valid but above normal operational range - most severe level
1Data valid but below normal operational range - most severe level
2Data erratic, intermittent or incorrect
3Voltage above normal, or shorted to high source
4Voltage below normal, or shorted to low source
5Current below normal or open circuit
6Current above normal or grounded circuit
7Mechanical system not responding or out of adjustment
8Abnormal frequency, pulse width or period
9Abnormal update rate
10Abnormal rate of change
11Root cause not known
12Bad intelligent device or component
13Out of calibration
14Special instructions
15Data valid but above normal operating range - least severe level
16Data valid but above normal operating range - moderately severe level
17Data valid but below normal operating range - least severe level
18Data valid but below normal operating range - moderately severe level
19Received network data in error
20Data drifted high
21Data drifted low
22Reserved for SAE assignment
23Reserved for SAE assignment
24Reserved for SAE assignment
25Reserved for SAE assignment
26Reserved for SAE assignment
27Reserved for SAE assignment
28Reserved for SAE assignment
29Reserved for SAE assignment
30Reserved for SAE assignment
31Condition exists

Questions about code 1568

What does Cummins fault code 1568 mean?

Cummins 1568 is "Injector Solenoid Driver Cylinder 15 Circuit - Current Above Normal or Grounded Circuit". It maps to SPN 665 FMI 6. The driver or input for Injector Solenoid Driver Cylinder 15 Circuit sees more current than it should, which the ECM interprets as a short to ground: chafed insulation, a pinched harness, or a shorted coil / solenoid.

Which lamp does fault code 1568 turn on?

Amber WARNING lamp: It lights the amber CHECK ENGINE (warning) lamp. The engine keeps running, but a torque or speed derate may apply depending on the calibration and on how long the fault stays active.

How do I clear or permanently delete Cummins code 1568?

An active code goes inactive on its own once the condition is gone; the inactive record stays in the ECM fault history until it is cleared with Cummins INSITE (or a J1939 tool that supports the DM3 / DM11 clear). If the code keeps coming back because the part is gone, disconnected or not worth repairing, the lasting fix is to disable fault 1568 in the calibration: upload your .xcal to the ECFG Superstore file service, custom DTC delete from $150 (up to 30 codes), full DPF / EGR / SCR delete $500, and flash the returned file with Calterm or INSITE.

← All Cummins fault codes  ·  XCAL file service  ·  ECFG Superstore