ECFG Superstore › Cummins fault codes › 15783

Cummins fault code15783 · Hydrogen Recirculation Pump Motor Temperature

Hydrogen Recirculation Pump Motor Temperature - Condition Exists

Fault code15783 Cummins fault code as shown in INSITE / CaltermSPN517062 · Hydrogen Recirculation Pump Motor TemperatureFMI31 Condition existsOBD codenone (J1939 only)LampAmber WARNING lampCummins textHydrogen Recirculation Pump Motor Temperature - Condition ExistsFailure modeCondition Exists

What Cummins code 15783 means

This is not an electrical fault on a sensor. FMI 31 means the ECM has detected that the named condition for Hydrogen Recirculation Pump Motor Temperature is true. The fault code itself is the message; the fix is to find out why the ECM believes the condition exists.

It lights the amber CHECK ENGINE (warning) lamp. The engine keeps running, but a torque or speed derate may apply depending on the calibration and on how long the fault stays active.

On a generic J1939 scan tool, or on the dash of a Freightliner, Kenworth, Peterbilt, International or Volvo chassis, the same fault is shown as SPN 517062 FMI 31 rather than as Cummins code 15783. Cummins INSITE and Calterm show the Cummins number, the SPN / FMI pair and the lamp together.

Fix the file: delete code 15783 from your calibration
from $150

Custom DTC delete, up to 30 codes, $150. Full DPF / EGR / SCR delete with all related codes and derates, $500. Upload your Calterm .xcal, tick the services, pay with PayPal, and the finished file comes back by email and WhatsApp.

Upload your .xcal →
ECFG definition files for your ECM
1,800 files

Cummins ECFG / E2M definitions for CM550, CM552, CM554, CM570, CM800, CM850, CM870, CM871 and more: the fault table, torque, fuelling, boost, EGR, DPF and SCR maps, ready for Calterm or WinOLS. Instant download.

Find your ECFG →

Other Cummins codes on SPN 517062 Hydrogen Recirculation Pump Motor Temperature

3 other fault codes share this SPN; each one is a different failure mode (FMI) of the same component.

14738 FMI 014873 FMI 1615622 FMI 15

All codes grouped by SPN →

Related Cummins fault codes

15778 · SPN 517060 FMI 31Hydrogen Recirculation Pump Hardware15779 · SPN 516385 FMI 31Hydrogen Recirculation Pump Isolation15781 · SPN 516386 FMI 31Hydrogen Recirculation Pump Low Voltage Supply15782 · SPN 517061 FMI 31Hydrogen Recirculation Pump MCU Temperature15784 · SPN 517057 FMI 11Hydrogen Recirculation Pump15785 · SPN 517057 FMI 19Hydrogen Recirculation Pump15786 · SPN 517064 FMI 31Hydrogen Recirculation Pump Software15787 · SPN 517387 FMI 13Stack Coolant Temperature

J1939 failure mode identifiers (FMI)

FMI 31 is highlighted. The FMI is the second half of every J1939 fault and tells you how the component failed; the SPN tells you which component.

FMIMeaning (SAE J1939-73)
0Data valid but above normal operational range - most severe level
1Data valid but below normal operational range - most severe level
2Data erratic, intermittent or incorrect
3Voltage above normal, or shorted to high source
4Voltage below normal, or shorted to low source
5Current below normal or open circuit
6Current above normal or grounded circuit
7Mechanical system not responding or out of adjustment
8Abnormal frequency, pulse width or period
9Abnormal update rate
10Abnormal rate of change
11Root cause not known
12Bad intelligent device or component
13Out of calibration
14Special instructions
15Data valid but above normal operating range - least severe level
16Data valid but above normal operating range - moderately severe level
17Data valid but below normal operating range - least severe level
18Data valid but below normal operating range - moderately severe level
19Received network data in error
20Data drifted high
21Data drifted low
22Reserved for SAE assignment
23Reserved for SAE assignment
24Reserved for SAE assignment
25Reserved for SAE assignment
26Reserved for SAE assignment
27Reserved for SAE assignment
28Reserved for SAE assignment
29Reserved for SAE assignment
30Reserved for SAE assignment
31Condition exists

Questions about code 15783

What does Cummins fault code 15783 mean?

Cummins 15783 is "Hydrogen Recirculation Pump Motor Temperature - Condition Exists". It maps to SPN 517062 FMI 31. This is not an electrical fault on a sensor. FMI 31 means the ECM has detected that the named condition for Hydrogen Recirculation Pump Motor Temperature is true. The fault code itself is the message; the fix is to find out why the ECM believes the condition

Which lamp does fault code 15783 turn on?

Amber WARNING lamp: It lights the amber CHECK ENGINE (warning) lamp. The engine keeps running, but a torque or speed derate may apply depending on the calibration and on how long the fault stays active.

How do I clear or permanently delete Cummins code 15783?

An active code goes inactive on its own once the condition is gone; the inactive record stays in the ECM fault history until it is cleared with Cummins INSITE (or a J1939 tool that supports the DM3 / DM11 clear). If the code keeps coming back because the part is gone, disconnected or not worth repairing, the lasting fix is to disable fault 15783 in the calibration: upload your .xcal to the ECFG Superstore file service, custom DTC delete from $150 (up to 30 codes), full DPF / EGR / SCR delete $500, and flash the returned file with Calterm or INSITE.

← All Cummins fault codes  ·  XCAL file service  ·  ECFG Superstore