ECFG Superstore › Cummins fault codes › 15982

Cummins fault code15982 · Aftertreatment 1 Outlet NOx 1

Aftertreatment 1 Outlet NOx 1 - Special Instructions

Fault code15982 Cummins fault code as shown in INSITE / CaltermSPN3226 · Aftertreatment 1 Outlet NOx SensorFMI14 Special instructionsOBD codenone (J1939 only)LampNo lampCummins textAftertreatment 1 Outlet NOx 1 - Special InstructionsFailure modeSpecial Instructions

What Cummins code 15982 means

The ECM has logged Aftertreatment 1 Outlet NOx 1 with a special instruction. The exact meaning is specific to this fault code in the Cummins troubleshooting manual rather than a generic electrical failure mode.

No dash lamp is attached to this code in the Cummins fault table. It is logged in the ECM and shows up in Cummins INSITE (or any J1939 tool reading DM1 / DM2), but on its own it does not light a lamp.

On a generic J1939 scan tool, or on the dash of a Freightliner, Kenworth, Peterbilt, International or Volvo chassis, the same fault is shown as SPN 3226 FMI 14 rather than as Cummins code 15982. Cummins INSITE and Calterm show the Cummins number, the SPN / FMI pair and the lamp together.

This is an emissions-system code. If the component it refers to has been removed or unplugged (DPF, EGR, SCR / DEF or NOx sensor delete) the code will keep returning and the derate with it, however many times it is cleared, because the diagnostic is still enabled in the calibration. The lasting fix in that case is to disable the fault in the .xcal itself.

Fix the file: delete code 15982 from your calibration
from $150

Custom DTC delete, up to 30 codes, $150. Full DPF / EGR / SCR delete with all related codes and derates, $500. Upload your Calterm .xcal, tick the services, pay with PayPal, and the finished file comes back by email and WhatsApp.

Upload your .xcal →
ECFG definition files for your ECM
1,800 files

Cummins ECFG / E2M definitions for CM550, CM552, CM554, CM570, CM800, CM850, CM870, CM871 and more: the fault table, torque, fuelling, boost, EGR, DPF and SCR maps, ready for Calterm or WinOLS. Instant download.

Find your ECFG →

Other Cummins codes on SPN 3226 Aftertreatment 1 Outlet NOx Sensor

26 other fault codes share this SPN; each one is a different failure mode (FMI) of the same component.

1694 FMI 2 · P22011886 FMI 3 · P22031887 FMI 4 · P22A02771 FMI 9 · U029E2772 FMI 152773 FMI 03395 FMI 163545 FMI 10 · U059F3717 FMI 13 · P22A23749 FMI 20 · P229F4452 FMI 75689 FMI 116462 FMI 206463 FMI 216464 FMI 26521 FMI 46565 FMI 107319 FMI 3112524 FMI 513184 FMI 913224 FMI 1313225 FMI 413227 FMI 1013228 FMI 413248 FMI 417544 FMI 22

All codes grouped by SPN →

Related Cummins fault codes

15977 · SPN 517486 FMI 9PGN65524 Message15978 · SPN 517487 FMI 9PGN65525 Message15979 · SPN 517485 FMI 9PGN65523 Message15981 · SPN 3216 FMI 14Aftertreatment 1 SCR Intake NOx 115983 · SPN 1675 FMI 9Engine Starter Mode15984 · SPN 517488 FMI 3Engine Turbocharger Wastegate Pressure Sensor15985 · SPN 517488 FMI 4Engine Turbocharger Wastegate Pressure Sensor15986 · SPN 7658 FMI 10Aftertreatment 1 Intake NOx Sensor 2 Self-diagnosis Status

J1939 failure mode identifiers (FMI)

FMI 14 is highlighted. The FMI is the second half of every J1939 fault and tells you how the component failed; the SPN tells you which component.

FMIMeaning (SAE J1939-73)
0Data valid but above normal operational range - most severe level
1Data valid but below normal operational range - most severe level
2Data erratic, intermittent or incorrect
3Voltage above normal, or shorted to high source
4Voltage below normal, or shorted to low source
5Current below normal or open circuit
6Current above normal or grounded circuit
7Mechanical system not responding or out of adjustment
8Abnormal frequency, pulse width or period
9Abnormal update rate
10Abnormal rate of change
11Root cause not known
12Bad intelligent device or component
13Out of calibration
14Special instructions
15Data valid but above normal operating range - least severe level
16Data valid but above normal operating range - moderately severe level
17Data valid but below normal operating range - least severe level
18Data valid but below normal operating range - moderately severe level
19Received network data in error
20Data drifted high
21Data drifted low
22Reserved for SAE assignment
23Reserved for SAE assignment
24Reserved for SAE assignment
25Reserved for SAE assignment
26Reserved for SAE assignment
27Reserved for SAE assignment
28Reserved for SAE assignment
29Reserved for SAE assignment
30Reserved for SAE assignment
31Condition exists

Questions about code 15982

What does Cummins fault code 15982 mean?

Cummins 15982 is "Aftertreatment 1 Outlet NOx 1 - Special Instructions". It maps to SPN 3226 FMI 14. The ECM has logged Aftertreatment 1 Outlet NOx 1 with a special instruction. The exact meaning is specific to this fault code in the Cummins troubleshooting manual rather than a generic electrical failure mode.

Which lamp does fault code 15982 turn on?

No lamp: No dash lamp is attached to this code in the Cummins fault table. It is logged in the ECM and shows up in Cummins INSITE (or any J1939 tool reading DM1 / DM2), but on its own it does not light a lamp.

How do I clear or permanently delete Cummins code 15982?

An active code goes inactive on its own once the condition is gone; the inactive record stays in the ECM fault history until it is cleared with Cummins INSITE (or a J1939 tool that supports the DM3 / DM11 clear). If the code keeps coming back because the part is gone, disconnected or not worth repairing, the lasting fix is to disable fault 15982 in the calibration: upload your .xcal to the ECFG Superstore file service, custom DTC delete from $150 (up to 30 codes), full DPF / EGR / SCR delete $500, and flash the returned file with Calterm or INSITE.

← All Cummins fault codes  ·  XCAL file service  ·  ECFG Superstore