ECFG Superstore › Cummins fault codes › 16659

Cummins fault code16659 · Motor/Generator 1 Inverter Control Module- Received Network Data in Error: (Multiplexed Data)

Motor/Generator 1 Inverter Control Module- Received Network Data in Error: (Multiplexed Data)

Fault code16659 Cummins fault code as shown in INSITE / CaltermSPN9436 · Propulsion Inverter 1 Control ModuleFMI19 Received network data in errorOBD codenone (J1939 only)LampNo lampCummins textMotor/Generator 1 Inverter Control Module- Received Network Data in Error: (Multiplexed Data)Failure modeReceived network data in error

What Cummins code 16659 means

Another module on the datalink is sending the ECM a value for Motor/Generator 1 Inverter Control Module- Received Network Data in Error: (Multiplexed Data) that is flagged as an error or is out of the valid range. The sensor may be fine; the fault points at the module that broadcasts the value or at the datalink wiring.

No dash lamp is attached to this code in the Cummins fault table. It is logged in the ECM and shows up in Cummins INSITE (or any J1939 tool reading DM1 / DM2), but on its own it does not light a lamp.

On a generic J1939 scan tool, or on the dash of a Freightliner, Kenworth, Peterbilt, International or Volvo chassis, the same fault is shown as SPN 9436 FMI 19 rather than as Cummins code 16659. Cummins INSITE and Calterm show the Cummins number, the SPN / FMI pair and the lamp together.

Fix the file: delete code 16659 from your calibration
from $150

Custom DTC delete, up to 30 codes, $150. Full DPF / EGR / SCR delete with all related codes and derates, $500. Upload your Calterm .xcal, tick the services, pay with PayPal, and the finished file comes back by email and WhatsApp.

Upload your .xcal →
ECFG definition files for your ECM
1,800 files

Cummins ECFG / E2M definitions for CM550, CM552, CM554, CM570, CM800, CM850, CM870, CM871 and more: the fault table, torque, fuelling, boost, EGR, DPF and SCR maps, ready for Calterm or WinOLS. Instant download.

Find your ECFG →

Other Cummins codes on SPN 9436 Propulsion Inverter 1 Control Module

17 other fault codes share this SPN; each one is a different failure mode (FMI) of the same component.

7898 FMI 137899 FMI 97923 FMI 1211393 FMI 1116376 FMI 916377 FMI 1316421 FMI 1216656 FMI 716657 FMI 3116662 FMI 916664 FMI 216739 FMI 3117161 FMI 417162 FMI 317268 FMI 1517269 FMI 1617271 FMI 0

All codes grouped by SPN →

Related Cummins fault codes

16655 · SPN 9437 FMI 31Motor/Generator 2 Inverter Control Module- Condition Exists16656 · SPN 9436 FMI 7Motor/Generator 1 Inverter Control Module- Mechanical System16657 · SPN 9436 FMI 31Motor/Generator 1 Inverter Control Module- Condition Exists16658 · SPN 9437 FMI 19Motor/Generator 2 Inverter Control Module- Received Network16661 · SPN 9437 FMI 9Motor/Generator 2 Inverter Control Module- Abnormal Update16662 · SPN 9436 FMI 9Motor/Generator 1 Inverter Control Module- Abnormal Update16663 · SPN 9437 FMI 2Motor/Generator 2 Inverter Control Module16664 · SPN 9436 FMI 2Motor/Generator 1 Inverter Control Module

J1939 failure mode identifiers (FMI)

FMI 19 is highlighted. The FMI is the second half of every J1939 fault and tells you how the component failed; the SPN tells you which component.

FMIMeaning (SAE J1939-73)
0Data valid but above normal operational range - most severe level
1Data valid but below normal operational range - most severe level
2Data erratic, intermittent or incorrect
3Voltage above normal, or shorted to high source
4Voltage below normal, or shorted to low source
5Current below normal or open circuit
6Current above normal or grounded circuit
7Mechanical system not responding or out of adjustment
8Abnormal frequency, pulse width or period
9Abnormal update rate
10Abnormal rate of change
11Root cause not known
12Bad intelligent device or component
13Out of calibration
14Special instructions
15Data valid but above normal operating range - least severe level
16Data valid but above normal operating range - moderately severe level
17Data valid but below normal operating range - least severe level
18Data valid but below normal operating range - moderately severe level
19Received network data in error
20Data drifted high
21Data drifted low
22Reserved for SAE assignment
23Reserved for SAE assignment
24Reserved for SAE assignment
25Reserved for SAE assignment
26Reserved for SAE assignment
27Reserved for SAE assignment
28Reserved for SAE assignment
29Reserved for SAE assignment
30Reserved for SAE assignment
31Condition exists

Questions about code 16659

What does Cummins fault code 16659 mean?

Cummins 16659 is "Motor/Generator 1 Inverter Control Module- Received Network Data in Error: (Multiplexed Data)". It maps to SPN 9436 FMI 19. Another module on the datalink is sending the ECM a value for Motor/Generator 1 Inverter Control Module- Received Network Data in Error: (Multiplexed Data) that is flagged as an error or is out of the valid range. The sensor may be fine; the fault points at

Which lamp does fault code 16659 turn on?

No lamp: No dash lamp is attached to this code in the Cummins fault table. It is logged in the ECM and shows up in Cummins INSITE (or any J1939 tool reading DM1 / DM2), but on its own it does not light a lamp.

How do I clear or permanently delete Cummins code 16659?

An active code goes inactive on its own once the condition is gone; the inactive record stays in the ECM fault history until it is cleared with Cummins INSITE (or a J1939 tool that supports the DM3 / DM11 clear). If the code keeps coming back because the part is gone, disconnected or not worth repairing, the lasting fix is to disable fault 16659 in the calibration: upload your .xcal to the ECFG Superstore file service, custom DTC delete from $150 (up to 30 codes), full DPF / EGR / SCR delete $500, and flash the returned file with Calterm or INSITE.

← All Cummins fault codes  ·  XCAL file service  ·  ECFG Superstore