ECFG Superstore › Cummins fault codes › 17433

Cummins fault code17433 · Shift Actuator Position Sensor 2

Shift Actuator Position Sensor 2 - Rear Axle - Voltage Above Normal or Shorted to High Source

Fault code17433 Cummins fault code as shown in INSITE / CaltermSPN517175 · Shift Actuator Position Sensor 2FMI3 Voltage above normal, or shorted to high sourceOBD codenone (J1939 only)LampRed STOP lampCummins textShift Actuator Position Sensor 2 - Rear Axle - Voltage Above Normal or Shorted to High SourceFailure modeRear Axle - Voltage Above Normal or Shorted to High Source

What Cummins code 17433 means

The signal wire for Shift Actuator Position Sensor 2 is sitting above the voltage window the ECM expects. In practice that is usually an open signal or return wire (the ECM pull-up takes the input high), a short to the 5 V supply or battery, or a failed sensor element.

It turns on the red STOP ENGINE lamp. Cummins classes this as a fault that can damage the engine or aftertreatment if ignored: stop as soon as it is safe to do so. Many calibrations also apply an engine-protection derate while the fault is active.

On a generic J1939 scan tool, or on the dash of a Freightliner, Kenworth, Peterbilt, International or Volvo chassis, the same fault is shown as SPN 517175 FMI 3 rather than as Cummins code 17433. Cummins INSITE and Calterm show the Cummins number, the SPN / FMI pair and the lamp together.

Fix the file: delete code 17433 from your calibration
from $150

Custom DTC delete, up to 30 codes, $150. Full DPF / EGR / SCR delete with all related codes and derates, $500. Upload your Calterm .xcal, tick the services, pay with PayPal, and the finished file comes back by email and WhatsApp.

Upload your .xcal →
ECFG definition files for your ECM
1,800 files

Cummins ECFG / E2M definitions for CM550, CM552, CM554, CM570, CM800, CM850, CM870, CM871 and more: the fault table, torque, fuelling, boost, EGR, DPF and SCR maps, ready for Calterm or WinOLS. Instant download.

Find your ECFG →

Other Cummins codes on SPN 517175 Shift Actuator Position Sensor 2

2 other fault codes share this SPN; each one is a different failure mode (FMI) of the same component.

17432 FMI 217434 FMI 5

All codes grouped by SPN →

Related Cummins fault codes

17428 · SPN 517174 FMI 2Shift Actuator Position Sensor 217429 · SPN 517174 FMI 3Shift Actuator Position Sensor 217431 · SPN 517174 FMI 5Shift Actuator Position Sensor 217432 · SPN 517175 FMI 2Shift Actuator Position Sensor 217434 · SPN 517175 FMI 5Shift Actuator Position Sensor 217435 · SPN 517176 FMI 31Output Shaft Speed Direction Rationality Fault17436 · SPN 517177 FMI 31Output Shaft Speed Direction Rationality Fault17437 · SPN 22169 FMI 14Brake Control Module

J1939 failure mode identifiers (FMI)

FMI 3 is highlighted. The FMI is the second half of every J1939 fault and tells you how the component failed; the SPN tells you which component.

FMIMeaning (SAE J1939-73)
0Data valid but above normal operational range - most severe level
1Data valid but below normal operational range - most severe level
2Data erratic, intermittent or incorrect
3Voltage above normal, or shorted to high source
4Voltage below normal, or shorted to low source
5Current below normal or open circuit
6Current above normal or grounded circuit
7Mechanical system not responding or out of adjustment
8Abnormal frequency, pulse width or period
9Abnormal update rate
10Abnormal rate of change
11Root cause not known
12Bad intelligent device or component
13Out of calibration
14Special instructions
15Data valid but above normal operating range - least severe level
16Data valid but above normal operating range - moderately severe level
17Data valid but below normal operating range - least severe level
18Data valid but below normal operating range - moderately severe level
19Received network data in error
20Data drifted high
21Data drifted low
22Reserved for SAE assignment
23Reserved for SAE assignment
24Reserved for SAE assignment
25Reserved for SAE assignment
26Reserved for SAE assignment
27Reserved for SAE assignment
28Reserved for SAE assignment
29Reserved for SAE assignment
30Reserved for SAE assignment
31Condition exists

Questions about code 17433

What does Cummins fault code 17433 mean?

Cummins 17433 is "Shift Actuator Position Sensor 2 - Rear Axle - Voltage Above Normal or Shorted to High Source". It maps to SPN 517175 FMI 3. The signal wire for Shift Actuator Position Sensor 2 is sitting above the voltage window the ECM expects. In practice that is usually an open signal or return wire (the ECM pull-up takes the input high), a short to the 5 V supply or battery, or a failed sensor

Which lamp does fault code 17433 turn on?

Red STOP lamp: It turns on the red STOP ENGINE lamp. Cummins classes this as a fault that can damage the engine or aftertreatment if ignored: stop as soon as it is safe to do so. Many calibrations also apply an engine-protection derate while the fault is active.

How do I clear or permanently delete Cummins code 17433?

An active code goes inactive on its own once the condition is gone; the inactive record stays in the ECM fault history until it is cleared with Cummins INSITE (or a J1939 tool that supports the DM3 / DM11 clear). If the code keeps coming back because the part is gone, disconnected or not worth repairing, the lasting fix is to disable fault 17433 in the calibration: upload your .xcal to the ECFG Superstore file service, custom DTC delete from $150 (up to 30 codes), full DPF / EGR / SCR delete $500, and flash the returned file with Calterm or INSITE.

← All Cummins fault codes  ·  XCAL file service  ·  ECFG Superstore