ECFG Superstore › Cummins fault codes › 17487

Cummins fault code17487 · Communications Bit Error Rate

Communications Bit Error Rate - Data Valid But Above Normal Operating Range - Most Severe Level

Fault code17487 Cummins fault code as shown in INSITE / CaltermSPN2855 · Communications Bit Error RateFMI0 Data valid but above normal operational range - most severe levelOBD codenone (J1939 only)LampNo lampCummins textCommunications Bit Error Rate - Data Valid But Above Normal Operating Range - Most Severe LevelFailure modeData Valid But Above Normal Operating Range - Most Severe Level

What Cummins code 17487 means

The reading for Communications Bit Error Rate is believed to be correct, but it has gone above the highest limit in the calibration. This is the most severe of the three "above range" levels (FMI 15, 16 and 0), so the ECM is reporting a real operating problem rather than a wiring fault.

No dash lamp is attached to this code in the Cummins fault table. It is logged in the ECM and shows up in Cummins INSITE (or any J1939 tool reading DM1 / DM2), but on its own it does not light a lamp.

On a generic J1939 scan tool, or on the dash of a Freightliner, Kenworth, Peterbilt, International or Volvo chassis, the same fault is shown as SPN 2855 FMI 0 rather than as Cummins code 17487. Cummins INSITE and Calterm show the Cummins number, the SPN / FMI pair and the lamp together.

Fix the file: delete code 17487 from your calibration
from $150

Custom DTC delete, up to 30 codes, $150. Full DPF / EGR / SCR delete with all related codes and derates, $500. Upload your Calterm .xcal, tick the services, pay with PayPal, and the finished file comes back by email and WhatsApp.

Upload your .xcal →
ECFG definition files for your ECM
1,800 files

Cummins ECFG / E2M definitions for CM550, CM552, CM554, CM570, CM800, CM850, CM870, CM871 and more: the fault table, torque, fuelling, boost, EGR, DPF and SCR maps, ready for Calterm or WinOLS. Instant download.

Find your ECFG →

Other Cummins codes on SPN 2855 Communications Bit Error Rate

Code 17487 is the only Cummins fault code assigned to SPN 2855.

All codes grouped by SPN →

Related Cummins fault codes

17483 · SPN 9402 FMI 2Propulsion Inverter 1 Internal Power Supply 2 Voltage17484 · SPN 5890 FMI 16Hybrid System Temperature17485 · SPN 5890 FMI 0Hybrid System Temperature17486 · SPN 9110 FMI 12Motor/Generator 2 Inverter Power Module Switch17488 · SPN 9109 FMI 12Propulsion Motor 1 Inverter Power Module Switch17489 · SPN 9109 FMI 16Propulsion Motor 1 Inverter Power Module Switch17491 · SPN 9109 FMI 0Propulsion Motor 1 Inverter Power Module Switch17492 · SPN 9067 FMI 13Propulsion Motor 1 Speed Sensors

J1939 failure mode identifiers (FMI)

FMI 0 is highlighted. The FMI is the second half of every J1939 fault and tells you how the component failed; the SPN tells you which component.

FMIMeaning (SAE J1939-73)
0Data valid but above normal operational range - most severe level
1Data valid but below normal operational range - most severe level
2Data erratic, intermittent or incorrect
3Voltage above normal, or shorted to high source
4Voltage below normal, or shorted to low source
5Current below normal or open circuit
6Current above normal or grounded circuit
7Mechanical system not responding or out of adjustment
8Abnormal frequency, pulse width or period
9Abnormal update rate
10Abnormal rate of change
11Root cause not known
12Bad intelligent device or component
13Out of calibration
14Special instructions
15Data valid but above normal operating range - least severe level
16Data valid but above normal operating range - moderately severe level
17Data valid but below normal operating range - least severe level
18Data valid but below normal operating range - moderately severe level
19Received network data in error
20Data drifted high
21Data drifted low
22Reserved for SAE assignment
23Reserved for SAE assignment
24Reserved for SAE assignment
25Reserved for SAE assignment
26Reserved for SAE assignment
27Reserved for SAE assignment
28Reserved for SAE assignment
29Reserved for SAE assignment
30Reserved for SAE assignment
31Condition exists

Questions about code 17487

What does Cummins fault code 17487 mean?

Cummins 17487 is "Communications Bit Error Rate - Data Valid But Above Normal Operating Range - Most Severe Level". It maps to SPN 2855 FMI 0. The reading for Communications Bit Error Rate is believed to be correct, but it has gone above the highest limit in the calibration. This is the most severe of the three "above range" levels (FMI 15, 16 and 0), so the ECM is reporting a real operating problem

Which lamp does fault code 17487 turn on?

No lamp: No dash lamp is attached to this code in the Cummins fault table. It is logged in the ECM and shows up in Cummins INSITE (or any J1939 tool reading DM1 / DM2), but on its own it does not light a lamp.

How do I clear or permanently delete Cummins code 17487?

An active code goes inactive on its own once the condition is gone; the inactive record stays in the ECM fault history until it is cleared with Cummins INSITE (or a J1939 tool that supports the DM3 / DM11 clear). If the code keeps coming back because the part is gone, disconnected or not worth repairing, the lasting fix is to disable fault 17487 in the calibration: upload your .xcal to the ECFG Superstore file service, custom DTC delete from $150 (up to 30 codes), full DPF / EGR / SCR delete $500, and flash the returned file with Calterm or INSITE.

← All Cummins fault codes  ·  XCAL file service  ·  ECFG Superstore