ECFG Superstore › Cummins fault codes › 3459

Cummins fault code3459 · EGR Cooler Bypass Actuator Circuit

EGR Cooler Bypass Actuator Circuit - Voltage Above Normal or Shorted to High Source

Fault code3459 Cummins fault code as shown in INSITE / CaltermSPN5393 · EGR Cooler Bypass Actuator CircuitFMI3 Voltage above normal, or shorted to high sourceOBD codeP245DLampAmber WARNING lampCummins textEGR Cooler Bypass Actuator Circuit - Voltage Above Normal or Shorted to High SourceFailure modeVoltage Above Normal or Shorted to High Source

What Cummins code 3459 means

The signal wire for EGR Cooler Bypass Actuator Circuit is sitting above the voltage window the ECM expects. In practice that is usually an open signal or return wire (the ECM pull-up takes the input high), a short to the 5 V supply or battery, or a failed sensor element.

It lights the amber CHECK ENGINE (warning) lamp. The engine keeps running, but a torque or speed derate may apply depending on the calibration and on how long the fault stays active.

On a generic J1939 scan tool, or on the dash of a Freightliner, Kenworth, Peterbilt, International or Volvo chassis, the same fault is shown as SPN 5393 FMI 3 rather than as Cummins code 3459; an OBD-II reader shows it as P245D. Cummins INSITE and Calterm show the Cummins number, the SPN / FMI pair and the lamp together.

This is an emissions-system code. If the component it refers to has been removed or unplugged (DPF, EGR, SCR / DEF or NOx sensor delete) the code will keep returning and the derate with it, however many times it is cleared, because the diagnostic is still enabled in the calibration. The lasting fix in that case is to disable the fault in the .xcal itself.

Fault code 3459 is defined in the fault tables of the Cummins calibrations we have analysed, so it is a real, current code rather than a legacy number.

Fix the file: delete code 3459 from your calibration
from $150

Custom DTC delete, up to 30 codes, $150. Full DPF / EGR / SCR delete with all related codes and derates, $500. Upload your Calterm .xcal, tick the services, pay with PayPal, and the finished file comes back by email and WhatsApp.

Upload your .xcal →
ECFG definition files for your ECM
1,800 files

Cummins ECFG / E2M definitions for CM550, CM552, CM554, CM570, CM800, CM850, CM870, CM871 and more: the fault table, torque, fuelling, boost, EGR, DPF and SCR maps, ready for Calterm or WinOLS. Instant download.

Find your ECFG →

Other Cummins codes on SPN 5393 EGR Cooler Bypass Actuator Circuit

5 other fault codes share this SPN; each one is a different failure mode (FMI) of the same component.

2726 FMI 7 · P245A3461 FMI 4 · P245C3581 FMI 2 · P245B3642 FMI 5 · P245A4613 FMI 13

All codes grouped by SPN →

Related Cummins fault codes

3455 · SPN 520463 FMI 2Aftertreatment Exhaust Gas Temperature 43456 · SPN 520463 FMI 16Aftertreatment Exhaust Gas Temperature 43457 · SPN 520464 FMI 31Loss of Bus Voltage Sensing3458 · SPN 731 FMI 31Knock Sensor Based Engine Derate3461 · SPN 5393 FMI 4EGR Cooler Bypass Actuator Circuit3462 · SPN 5401 FMI 2Engine Turbocharger Turbine Bypass Actuator3463 · SPN 5401 FMI 4Engine Turbocharger Turbine Bypass Actuator3464 · SPN 5401 FMI 7Engine Turbocharger Turbine Bypass Actuator

J1939 failure mode identifiers (FMI)

FMI 3 is highlighted. The FMI is the second half of every J1939 fault and tells you how the component failed; the SPN tells you which component.

FMIMeaning (SAE J1939-73)
0Data valid but above normal operational range - most severe level
1Data valid but below normal operational range - most severe level
2Data erratic, intermittent or incorrect
3Voltage above normal, or shorted to high source
4Voltage below normal, or shorted to low source
5Current below normal or open circuit
6Current above normal or grounded circuit
7Mechanical system not responding or out of adjustment
8Abnormal frequency, pulse width or period
9Abnormal update rate
10Abnormal rate of change
11Root cause not known
12Bad intelligent device or component
13Out of calibration
14Special instructions
15Data valid but above normal operating range - least severe level
16Data valid but above normal operating range - moderately severe level
17Data valid but below normal operating range - least severe level
18Data valid but below normal operating range - moderately severe level
19Received network data in error
20Data drifted high
21Data drifted low
22Reserved for SAE assignment
23Reserved for SAE assignment
24Reserved for SAE assignment
25Reserved for SAE assignment
26Reserved for SAE assignment
27Reserved for SAE assignment
28Reserved for SAE assignment
29Reserved for SAE assignment
30Reserved for SAE assignment
31Condition exists

Questions about code 3459

What does Cummins fault code 3459 mean?

Cummins 3459 is "EGR Cooler Bypass Actuator Circuit - Voltage Above Normal or Shorted to High Source". It maps to SPN 5393 FMI 3 and OBD code P245D. The signal wire for EGR Cooler Bypass Actuator Circuit is sitting above the voltage window the ECM expects. In practice that is usually an open signal or return wire (the ECM pull-up takes the input high), a short to the 5 V supply or battery, or a failed

Which lamp does fault code 3459 turn on?

Amber WARNING lamp: It lights the amber CHECK ENGINE (warning) lamp. The engine keeps running, but a torque or speed derate may apply depending on the calibration and on how long the fault stays active.

How do I clear or permanently delete Cummins code 3459?

An active code goes inactive on its own once the condition is gone; the inactive record stays in the ECM fault history until it is cleared with Cummins INSITE (or a J1939 tool that supports the DM3 / DM11 clear). If the code keeps coming back because the part is gone, disconnected or not worth repairing, the lasting fix is to disable fault 3459 in the calibration: upload your .xcal to the ECFG Superstore file service, custom DTC delete from $150 (up to 30 codes), full DPF / EGR / SCR delete $500, and flash the returned file with Calterm or INSITE.

← All Cummins fault codes  ·  XCAL file service  ·  ECFG Superstore