ECFG Superstore › Cummins fault codes › 3539

Cummins fault code3539 · Engine Intake Throttle Actuator Position Sensor Circuit

Engine Intake Throttle Actuator Position Sensor Circuit - Voltage Above Normal or Shorted to High Source

Fault code3539 Cummins fault code as shown in INSITE / CaltermSPN51 · Engine Intake Throttle Actuator Position Sensor CircuitFMI3 Voltage above normal, or shorted to high sourceOBD codeP02E9LampAmber WARNING lampCummins textEngine Intake Throttle Actuator Position Sensor Circuit - Voltage Above Normal or Shorted to High SourceFailure modeVoltage Above Normal or Shorted to High Source

What Cummins code 3539 means

The signal wire for Engine Intake Throttle Actuator Position Sensor Circuit is sitting above the voltage window the ECM expects. In practice that is usually an open signal or return wire (the ECM pull-up takes the input high), a short to the 5 V supply or battery, or a failed sensor element.

It lights the amber CHECK ENGINE (warning) lamp. The engine keeps running, but a torque or speed derate may apply depending on the calibration and on how long the fault stays active.

On a generic J1939 scan tool, or on the dash of a Freightliner, Kenworth, Peterbilt, International or Volvo chassis, the same fault is shown as SPN 51 FMI 3 rather than as Cummins code 3539; an OBD-II reader shows it as P02E9. Cummins INSITE and Calterm show the Cummins number, the SPN / FMI pair and the lamp together.

Fault code 3539 is defined in the fault tables of the Cummins calibrations we have analysed and is one of the more commonly enabled codes, so it is a real, current code rather than a legacy number.

Fix the file: delete code 3539 from your calibration
from $150

Custom DTC delete, up to 30 codes, $150. Full DPF / EGR / SCR delete with all related codes and derates, $500. Upload your Calterm .xcal, tick the services, pay with PayPal, and the finished file comes back by email and WhatsApp.

Upload your .xcal →
ECFG definition files for your ECM
1,800 files

Cummins ECFG / E2M definitions for CM550, CM552, CM554, CM570, CM800, CM850, CM870, CM871 and more: the fault table, torque, fuelling, boost, EGR, DPF and SCR maps, ready for Calterm or WinOLS. Instant download.

Find your ECFG →

Other Cummins codes on SPN 51 Engine Intake Throttle Actuator Position Sensor Circuit

14 other fault codes share this SPN; each one is a different failure mode (FMI) of the same component.

512 FMI 3513 FMI 42189 FMI 72519 FMI 22618 FMI 83541 FMI 4 · P02E83542 FMI 2 · P02E76133 FMI 06134 FMI 16497 FMI 36498 FMI 47834 FMI 197835 FMI 1316981 FMI 10

All codes grouped by SPN →

Related Cummins fault codes

3535 · SPN 1213 FMI 9Malfunction Indicator Lamp3536 · SPN 1213 FMI 19Malfunction Indicator Lamp3537 · SPN 4765 FMI 18Aftertreatment 1 Diesel Oxidation Catalyst Intake3538 · SPN 3675 FMI 2Engine Turbocharger Compressor Bypass Actuator Position3541 · SPN 51 FMI 4Engine Intake Throttle Actuator Position Sensor Circuit3542 · SPN 51 FMI 2Engine Intake Throttle Actuator Position Sensor3543 · SPN 4094 FMI 31NOx Limits Exceeded Due to Insufficient Reagent Quality3544 · SPN 170 FMI 18Cab Interior Temperature

J1939 failure mode identifiers (FMI)

FMI 3 is highlighted. The FMI is the second half of every J1939 fault and tells you how the component failed; the SPN tells you which component.

FMIMeaning (SAE J1939-73)
0Data valid but above normal operational range - most severe level
1Data valid but below normal operational range - most severe level
2Data erratic, intermittent or incorrect
3Voltage above normal, or shorted to high source
4Voltage below normal, or shorted to low source
5Current below normal or open circuit
6Current above normal or grounded circuit
7Mechanical system not responding or out of adjustment
8Abnormal frequency, pulse width or period
9Abnormal update rate
10Abnormal rate of change
11Root cause not known
12Bad intelligent device or component
13Out of calibration
14Special instructions
15Data valid but above normal operating range - least severe level
16Data valid but above normal operating range - moderately severe level
17Data valid but below normal operating range - least severe level
18Data valid but below normal operating range - moderately severe level
19Received network data in error
20Data drifted high
21Data drifted low
22Reserved for SAE assignment
23Reserved for SAE assignment
24Reserved for SAE assignment
25Reserved for SAE assignment
26Reserved for SAE assignment
27Reserved for SAE assignment
28Reserved for SAE assignment
29Reserved for SAE assignment
30Reserved for SAE assignment
31Condition exists

Questions about code 3539

What does Cummins fault code 3539 mean?

Cummins 3539 is "Engine Intake Throttle Actuator Position Sensor Circuit - Voltage Above Normal or Shorted to High Source". It maps to SPN 51 FMI 3 and OBD code P02E9. The signal wire for Engine Intake Throttle Actuator Position Sensor Circuit is sitting above the voltage window the ECM expects. In practice that is usually an open signal or return wire (the ECM pull-up takes the input high), a short to the 5 V supply or

Which lamp does fault code 3539 turn on?

Amber WARNING lamp: It lights the amber CHECK ENGINE (warning) lamp. The engine keeps running, but a torque or speed derate may apply depending on the calibration and on how long the fault stays active.

How do I clear or permanently delete Cummins code 3539?

An active code goes inactive on its own once the condition is gone; the inactive record stays in the ECM fault history until it is cleared with Cummins INSITE (or a J1939 tool that supports the DM3 / DM11 clear). If the code keeps coming back because the part is gone, disconnected or not worth repairing, the lasting fix is to disable fault 3539 in the calibration: upload your .xcal to the ECFG Superstore file service, custom DTC delete from $150 (up to 30 codes), full DPF / EGR / SCR delete $500, and flash the returned file with Calterm or INSITE.

← All Cummins fault codes  ·  XCAL file service  ·  ECFG Superstore