Cummins fault code5417 · Engine Glow Plug 3

Engine Glow Plug 3 - Data Erratic, Intermittent, or Incorrect

Fault code5417 Cummins fault code as shown in INSITE / CaltermSPN5326 · Engine Glow Plug 3FMI2 Data erratic, intermittent or incorrectOBD codeP06BBLampAmber WARNING lampCummins textEngine Glow Plug 3 - Data Erratic, Intermittent, or IncorrectFailure modeData Erratic, Intermittent, or Incorrect

What Cummins code 5417 means

The ECM is receiving a signal for Engine Glow Plug 3, but the value jumps around, drops out, or does not agree with other sensors it is checked against. Typical causes are a chafed harness, a corroded connector pin, a failing sensor, or, for a datalink value, another module sending bad data.

It lights the amber CHECK ENGINE (warning) lamp. The engine keeps running, but a torque or speed derate may apply depending on the calibration and on how long the fault stays active.

On a generic J1939 scan tool, or on the dash of a Freightliner, Kenworth, Peterbilt, International or Volvo chassis, the same fault is shown as SPN 5326 FMI 2 rather than as Cummins code 5417; an OBD-II reader shows it as P06BB. Cummins INSITE and Calterm show the Cummins number, the SPN / FMI pair and the lamp together.

Fix the file: delete code 5417 from your calibration
from $150

Custom DTC delete, up to 30 codes, $150. Full DPF / EGR / SCR delete with all related codes and derates, $500. Upload your Calterm .xcal, tick the services, pay with PayPal, and the finished file comes back by email and WhatsApp.

Upload your .xcal →
ECFG definition files for your ECM
1,800 files

Cummins ECFG / E2M definitions for CM550, CM552, CM554, CM570, CM800, CM850, CM870, CM871 and more: the fault table, torque, fuelling, boost, EGR, DPF and SCR maps, ready for Calterm or WinOLS. Instant download.

Find your ECFG →

Other Cummins codes on SPN 5326 Engine Glow Plug 3

Code 5417 is the only Cummins fault code assigned to SPN 5326.

All codes grouped by SPN →

Related Cummins fault codes

5413 · SPN 520831 FMI 3SCR Thermal Management Inhibit Switch5414 · SPN 520831 FMI 4SCR Thermal Management Inhibit Switch5415 · SPN 5324 FMI 2Engine Glow Plug 15416 · SPN 5325 FMI 2Engine Glow Plug 25418 · SPN 5327 FMI 2Engine Glow Plug 45419 · SPN 5328 FMI 2Engine Glow Plug 55421 · SPN 5329 FMI 2Engine Glow Plug 65422 · SPN 5330 FMI 2Engine Glow Plug 7

J1939 failure mode identifiers (FMI)

FMI 2 is highlighted. The FMI is the second half of every J1939 fault and tells you how the component failed; the SPN tells you which component.

FMIMeaning (SAE J1939-73)
0Data valid but above normal operational range - most severe level
1Data valid but below normal operational range - most severe level
2Data erratic, intermittent or incorrect
3Voltage above normal, or shorted to high source
4Voltage below normal, or shorted to low source
5Current below normal or open circuit
6Current above normal or grounded circuit
7Mechanical system not responding or out of adjustment
8Abnormal frequency, pulse width or period
9Abnormal update rate
10Abnormal rate of change
11Root cause not known
12Bad intelligent device or component
13Out of calibration
14Special instructions
15Data valid but above normal operating range - least severe level
16Data valid but above normal operating range - moderately severe level
17Data valid but below normal operating range - least severe level
18Data valid but below normal operating range - moderately severe level
19Received network data in error
20Data drifted high
21Data drifted low
22Reserved for SAE assignment
23Reserved for SAE assignment
24Reserved for SAE assignment
25Reserved for SAE assignment
26Reserved for SAE assignment
27Reserved for SAE assignment
28Reserved for SAE assignment
29Reserved for SAE assignment
30Reserved for SAE assignment
31Condition exists

Questions about code 5417

What does Cummins fault code 5417 mean?

Cummins 5417 is "Engine Glow Plug 3 - Data Erratic, Intermittent, or Incorrect". It maps to SPN 5326 FMI 2 and OBD code P06BB. The ECM is receiving a signal for Engine Glow Plug 3, but the value jumps around, drops out, or does not agree with other sensors it is checked against. Typical causes are a chafed harness, a corroded connector pin, a failing sensor, or, for a datalink value

Which lamp does fault code 5417 turn on?

Amber WARNING lamp: It lights the amber CHECK ENGINE (warning) lamp. The engine keeps running, but a torque or speed derate may apply depending on the calibration and on how long the fault stays active.

How do I clear or permanently delete Cummins code 5417?

An active code goes inactive on its own once the condition is gone; the inactive record stays in the ECM fault history until it is cleared with Cummins INSITE (or a J1939 tool that supports the DM3 / DM11 clear). If the code keeps coming back because the part is gone, disconnected or not worth repairing, the lasting fix is to disable fault 5417 in the calibration: upload your .xcal to the ECFG Superstore file service, custom DTC delete from $150 (up to 30 codes), full DPF / EGR / SCR delete $500, and flash the returned file with Calterm or INSITE.