ECFG Superstore › Cummins fault codes › 7582

Cummins fault code7582 · Exhaust Gas Pressure

Exhaust Gas Pressure - Data Valid But Below Normal Operating Range - Least Severe Level

Fault code7582 Cummins fault code as shown in INSITE / CaltermSPN1209 · Exhaust Gas PressureFMI17 Data valid but below normal operating range - least severe levelOBD codenone (J1939 only)LampNo lampCummins textExhaust Gas Pressure - Data Valid But Below Normal Operating Range - Least Severe LevelFailure modeData Valid But Below Normal Operating Range - Least Severe Level

What Cummins code 7582 means

The reading for Exhaust Gas Pressure is believed to be correct, but it has gone slightly below the normal operating range. This is the least severe of the three "below range" levels (FMI 17, 18 and 1); it is usually an early warning rather than an immediate problem.

No dash lamp is attached to this code in the Cummins fault table. It is logged in the ECM and shows up in Cummins INSITE (or any J1939 tool reading DM1 / DM2), but on its own it does not light a lamp.

On a generic J1939 scan tool, or on the dash of a Freightliner, Kenworth, Peterbilt, International or Volvo chassis, the same fault is shown as SPN 1209 FMI 17 rather than as Cummins code 7582. Cummins INSITE and Calterm show the Cummins number, the SPN / FMI pair and the lamp together.

Fault code 7582 is defined in the fault tables of the Cummins calibrations we have analysed and is one of the more commonly enabled codes, so it is a real, current code rather than a legacy number.

Fix the file: delete code 7582 from your calibration
from $150

Custom DTC delete, up to 30 codes, $150. Full DPF / EGR / SCR delete with all related codes and derates, $500. Upload your Calterm .xcal, tick the services, pay with PayPal, and the finished file comes back by email and WhatsApp.

Upload your .xcal →
ECFG definition files for your ECM
1,800 files

Cummins ECFG / E2M definitions for CM550, CM552, CM554, CM570, CM800, CM850, CM870, CM871 and more: the fault table, torque, fuelling, boost, EGR, DPF and SCR maps, ready for Calterm or WinOLS. Instant download.

Find your ECFG →

Other Cummins codes on SPN 1209 Exhaust Gas Pressure

17 other fault codes share this SPN; each one is a different failure mode (FMI) of the same component.

2373 FMI 3 · P04732374 FMI 4 · P04722554 FMI 2 · P04712764 FMI 16 · P04744598 FMI 204599 FMI 214728 FMI 185628 FMI 155629 FMI 05652 FMI 15 · P04747273 FMI 177412 FMI 317864 FMI 10 · P047113136 FMI 313137 FMI 413146 FMI 1013152 FMI 2

All codes grouped by SPN →

Related Cummins fault codes

7577 · SPN 1300 FMI 18Engine Spark Plug #7 Voltage7578 · SPN 1301 FMI 18Engine Spark Plug #8 Voltage7579 · SPN 1292 FMI 2Engine Ignition Control Module #17581 · SPN 1292 FMI 4Engine Ignition Control Module #17583 · SPN 102 FMI 15Intake Manifold 1 Pressure7584 · SPN 521147 FMI 11Generator failed to start7585 · SPN 7581 FMI 19Engine Gaseous Fuel Pressure Regulator 17586 · SPN 521148 FMI 19Engine Gaseous Fuel Pressure Regulator 2

J1939 failure mode identifiers (FMI)

FMI 17 is highlighted. The FMI is the second half of every J1939 fault and tells you how the component failed; the SPN tells you which component.

FMIMeaning (SAE J1939-73)
0Data valid but above normal operational range - most severe level
1Data valid but below normal operational range - most severe level
2Data erratic, intermittent or incorrect
3Voltage above normal, or shorted to high source
4Voltage below normal, or shorted to low source
5Current below normal or open circuit
6Current above normal or grounded circuit
7Mechanical system not responding or out of adjustment
8Abnormal frequency, pulse width or period
9Abnormal update rate
10Abnormal rate of change
11Root cause not known
12Bad intelligent device or component
13Out of calibration
14Special instructions
15Data valid but above normal operating range - least severe level
16Data valid but above normal operating range - moderately severe level
17Data valid but below normal operating range - least severe level
18Data valid but below normal operating range - moderately severe level
19Received network data in error
20Data drifted high
21Data drifted low
22Reserved for SAE assignment
23Reserved for SAE assignment
24Reserved for SAE assignment
25Reserved for SAE assignment
26Reserved for SAE assignment
27Reserved for SAE assignment
28Reserved for SAE assignment
29Reserved for SAE assignment
30Reserved for SAE assignment
31Condition exists

Questions about code 7582

What does Cummins fault code 7582 mean?

Cummins 7582 is "Exhaust Gas Pressure - Data Valid But Below Normal Operating Range - Least Severe Level". It maps to SPN 1209 FMI 17. The reading for Exhaust Gas Pressure is believed to be correct, but it has gone slightly below the normal operating range. This is the least severe of the three "below range" levels (FMI 17, 18 and 1); it is usually an early warning rather than an immediate

Which lamp does fault code 7582 turn on?

No lamp: No dash lamp is attached to this code in the Cummins fault table. It is logged in the ECM and shows up in Cummins INSITE (or any J1939 tool reading DM1 / DM2), but on its own it does not light a lamp.

How do I clear or permanently delete Cummins code 7582?

An active code goes inactive on its own once the condition is gone; the inactive record stays in the ECM fault history until it is cleared with Cummins INSITE (or a J1939 tool that supports the DM3 / DM11 clear). If the code keeps coming back because the part is gone, disconnected or not worth repairing, the lasting fix is to disable fault 7582 in the calibration: upload your .xcal to the ECFG Superstore file service, custom DTC delete from $150 (up to 30 codes), full DPF / EGR / SCR delete $500, and flash the returned file with Calterm or INSITE.