ECFG Superstore › Cummins fault codes › 7712

Cummins fault code7712 · Aftertreatment 1 SCR Outlet Absolute Pressure

Aftertreatment 1 SCR Outlet Absolute Pressure - Data Valid But Below Normal Operating Range - Least Severe Level

Fault code7712 Cummins fault code as shown in INSITE / CaltermSPN521174 · Aftertreatment 1 SCR Outlet Absolute PressureFMI17 Data valid but below normal operating range - least severe levelOBD codenone (J1939 only)LampAmber WARNING lampCummins textAftertreatment 1 SCR Outlet Absolute Pressure - Data Valid But Below Normal Operating Range - Least Severe LevelFailure modeData Valid But Below Normal Operating Range - Least Severe Level

What Cummins code 7712 means

The reading for Aftertreatment 1 SCR Outlet Absolute Pressure is believed to be correct, but it has gone slightly below the normal operating range. This is the least severe of the three "below range" levels (FMI 17, 18 and 1); it is usually an early warning rather than an immediate problem.

It lights the amber CHECK ENGINE (warning) lamp. The engine keeps running, but a torque or speed derate may apply depending on the calibration and on how long the fault stays active.

On a generic J1939 scan tool, or on the dash of a Freightliner, Kenworth, Peterbilt, International or Volvo chassis, the same fault is shown as SPN 521174 FMI 17 rather than as Cummins code 7712. Cummins INSITE and Calterm show the Cummins number, the SPN / FMI pair and the lamp together.

This is an emissions-system code. If the component it refers to has been removed or unplugged (DPF, EGR, SCR / DEF or NOx sensor delete) the code will keep returning and the derate with it, however many times it is cleared, because the diagnostic is still enabled in the calibration. The lasting fix in that case is to disable the fault in the .xcal itself.

Fix the file: delete code 7712 from your calibration
from $150

Custom DTC delete, up to 30 codes, $150. Full DPF / EGR / SCR delete with all related codes and derates, $500. Upload your Calterm .xcal, tick the services, pay with PayPal, and the finished file comes back by email and WhatsApp.

Upload your .xcal →
ECFG definition files for your ECM
1,800 files

Cummins ECFG / E2M definitions for CM550, CM552, CM554, CM570, CM800, CM850, CM870, CM871 and more: the fault table, torque, fuelling, boost, EGR, DPF and SCR maps, ready for Calterm or WinOLS. Instant download.

Find your ECFG →

Other Cummins codes on SPN 521174 Aftertreatment 1 SCR Outlet Absolute Pressure

5 other fault codes share this SPN; each one is a different failure mode (FMI) of the same component.

7699 FMI 157714 FMI 37716 FMI 47719 FMI 207721 FMI 21

All codes grouped by SPN →

Related Cummins fault codes

7697 · SPN 521173 FMI 31Bank cut-off FSO failure7698 · SPN 6797 FMI 15Aftertreatment 1 SCR Intake Absolute Pressure7699 · SPN 521174 FMI 15Aftertreatment 1 SCR Outlet Absolute Pressure7711 · SPN 6797 FMI 17Aftertreatment 1 SCR Intake Absolute Pressure7713 · SPN 6797 FMI 3Aftertreatment 1 SCR Intake Absolute Pressure7714 · SPN 521174 FMI 3Aftertreatment 1 SCR Outlet Absolute Pressure7715 · SPN 6797 FMI 4Aftertreatment 1 SCR Intake Absolute Pressure7716 · SPN 521174 FMI 4Aftertreatment 1 SCR Outlet Absolute Pressure

J1939 failure mode identifiers (FMI)

FMI 17 is highlighted. The FMI is the second half of every J1939 fault and tells you how the component failed; the SPN tells you which component.

FMIMeaning (SAE J1939-73)
0Data valid but above normal operational range - most severe level
1Data valid but below normal operational range - most severe level
2Data erratic, intermittent or incorrect
3Voltage above normal, or shorted to high source
4Voltage below normal, or shorted to low source
5Current below normal or open circuit
6Current above normal or grounded circuit
7Mechanical system not responding or out of adjustment
8Abnormal frequency, pulse width or period
9Abnormal update rate
10Abnormal rate of change
11Root cause not known
12Bad intelligent device or component
13Out of calibration
14Special instructions
15Data valid but above normal operating range - least severe level
16Data valid but above normal operating range - moderately severe level
17Data valid but below normal operating range - least severe level
18Data valid but below normal operating range - moderately severe level
19Received network data in error
20Data drifted high
21Data drifted low
22Reserved for SAE assignment
23Reserved for SAE assignment
24Reserved for SAE assignment
25Reserved for SAE assignment
26Reserved for SAE assignment
27Reserved for SAE assignment
28Reserved for SAE assignment
29Reserved for SAE assignment
30Reserved for SAE assignment
31Condition exists

Questions about code 7712

What does Cummins fault code 7712 mean?

Cummins 7712 is "Aftertreatment 1 SCR Outlet Absolute Pressure - Data Valid But Below Normal Operating Range - Least Severe Level". It maps to SPN 521174 FMI 17. The reading for Aftertreatment 1 SCR Outlet Absolute Pressure is believed to be correct, but it has gone slightly below the normal operating range. This is the least severe of the three "below range" levels (FMI 17, 18 and 1); it is usually an early warning

Which lamp does fault code 7712 turn on?

Amber WARNING lamp: It lights the amber CHECK ENGINE (warning) lamp. The engine keeps running, but a torque or speed derate may apply depending on the calibration and on how long the fault stays active.

How do I clear or permanently delete Cummins code 7712?

An active code goes inactive on its own once the condition is gone; the inactive record stays in the ECM fault history until it is cleared with Cummins INSITE (or a J1939 tool that supports the DM3 / DM11 clear). If the code keeps coming back because the part is gone, disconnected or not worth repairing, the lasting fix is to disable fault 7712 in the calibration: upload your .xcal to the ECFG Superstore file service, custom DTC delete from $150 (up to 30 codes), full DPF / EGR / SCR delete $500, and flash the returned file with Calterm or INSITE.

← All Cummins fault codes  ·  XCAL file service  ·  ECFG Superstore