ECFG Superstore › Cummins fault codes › 7982

Cummins fault code7982 · DC/DC 2 HVIL Status

DC/DC 2 HVIL Status - Current Below Normal or Open Circuit

Fault code7982 Cummins fault code as shown in INSITE / CaltermSPN8896 · DC/DC 2 HVIL StatusFMI5 Current below normal or open circuitOBD codenone (J1939 only)LampRed STOP lampCummins textDC/DC 2 HVIL Status - Current Below Normal or Open CircuitFailure modeCurrent Below Normal or Open Circuit

What Cummins code 7982 means

The driver or input for DC/DC 2 HVIL Status sees less current than it should, which the ECM interprets as an open circuit: a broken wire, an unplugged connector, or an open coil / solenoid.

It turns on the red STOP ENGINE lamp. Cummins classes this as a fault that can damage the engine or aftertreatment if ignored: stop as soon as it is safe to do so. Many calibrations also apply an engine-protection derate while the fault is active.

On a generic J1939 scan tool, or on the dash of a Freightliner, Kenworth, Peterbilt, International or Volvo chassis, the same fault is shown as SPN 8896 FMI 5 rather than as Cummins code 7982. Cummins INSITE and Calterm show the Cummins number, the SPN / FMI pair and the lamp together.

Fix the file: delete code 7982 from your calibration
from $150

Custom DTC delete, up to 30 codes, $150. Full DPF / EGR / SCR delete with all related codes and derates, $500. Upload your Calterm .xcal, tick the services, pay with PayPal, and the finished file comes back by email and WhatsApp.

Upload your .xcal →
ECFG definition files for your ECM
1,800 files

Cummins ECFG / E2M definitions for CM550, CM552, CM554, CM570, CM800, CM850, CM870, CM871 and more: the fault table, torque, fuelling, boost, EGR, DPF and SCR maps, ready for Calterm or WinOLS. Instant download.

Find your ECFG →

Other Cummins codes on SPN 8896 DC/DC 2 HVIL Status

Code 7982 is the only Cummins fault code assigned to SPN 8896.

All codes grouped by SPN →

Related Cummins fault codes

7977 · SPN 8895 FMI 12DC/DC 2 Operational Status7978 · SPN 8895 FMI 2DC/DC 2 Operational Status7979 · SPN 8895 FMI 3DC/DC 2 Operational Status7981 · SPN 8895 FMI 4DC/DC 2 Operational Status7983 · SPN 8911 FMI 4DC/DC 2 Low Side Voltage7984 · SPN 8911 FMI 3DC/DC 2 Low Side Voltage7985 · SPN 8911 FMI 31DC/DC 2 Low Side Voltage7986 · SPN 8912 FMI 2DC/DC 2 Low Side Current

J1939 failure mode identifiers (FMI)

FMI 5 is highlighted. The FMI is the second half of every J1939 fault and tells you how the component failed; the SPN tells you which component.

FMIMeaning (SAE J1939-73)
0Data valid but above normal operational range - most severe level
1Data valid but below normal operational range - most severe level
2Data erratic, intermittent or incorrect
3Voltage above normal, or shorted to high source
4Voltage below normal, or shorted to low source
5Current below normal or open circuit
6Current above normal or grounded circuit
7Mechanical system not responding or out of adjustment
8Abnormal frequency, pulse width or period
9Abnormal update rate
10Abnormal rate of change
11Root cause not known
12Bad intelligent device or component
13Out of calibration
14Special instructions
15Data valid but above normal operating range - least severe level
16Data valid but above normal operating range - moderately severe level
17Data valid but below normal operating range - least severe level
18Data valid but below normal operating range - moderately severe level
19Received network data in error
20Data drifted high
21Data drifted low
22Reserved for SAE assignment
23Reserved for SAE assignment
24Reserved for SAE assignment
25Reserved for SAE assignment
26Reserved for SAE assignment
27Reserved for SAE assignment
28Reserved for SAE assignment
29Reserved for SAE assignment
30Reserved for SAE assignment
31Condition exists

Questions about code 7982

What does Cummins fault code 7982 mean?

Cummins 7982 is "DC/DC 2 HVIL Status - Current Below Normal or Open Circuit". It maps to SPN 8896 FMI 5. The driver or input for DC/DC 2 HVIL Status sees less current than it should, which the ECM interprets as an open circuit: a broken wire, an unplugged connector, or an open coil / solenoid.

Which lamp does fault code 7982 turn on?

Red STOP lamp: It turns on the red STOP ENGINE lamp. Cummins classes this as a fault that can damage the engine or aftertreatment if ignored: stop as soon as it is safe to do so. Many calibrations also apply an engine-protection derate while the fault is active.

How do I clear or permanently delete Cummins code 7982?

An active code goes inactive on its own once the condition is gone; the inactive record stays in the ECM fault history until it is cleared with Cummins INSITE (or a J1939 tool that supports the DM3 / DM11 clear). If the code keeps coming back because the part is gone, disconnected or not worth repairing, the lasting fix is to disable fault 7982 in the calibration: upload your .xcal to the ECFG Superstore file service, custom DTC delete from $150 (up to 30 codes), full DPF / EGR / SCR delete $500, and flash the returned file with Calterm or INSITE.

← All Cummins fault codes  ·  XCAL file service  ·  ECFG Superstore