Cummins fault code8219 · Connectivity Module

Connectivity Module - Current Below Normal or Open Circuit

Fault code8219 Cummins fault code as shown in INSITE / CaltermSPN521209 · Connectivity ModuleFMI5 Current below normal or open circuitOBD codenone (J1939 only)LampNo lampCummins textConnectivity Module - Current Below Normal or Open CircuitFailure modeCurrent Below Normal or Open Circuit

What Cummins code 8219 means

The driver or input for Connectivity Module sees less current than it should, which the ECM interprets as an open circuit: a broken wire, an unplugged connector, or an open coil / solenoid.

No dash lamp is attached to this code in the Cummins fault table. It is logged in the ECM and shows up in Cummins INSITE (or any J1939 tool reading DM1 / DM2), but on its own it does not light a lamp.

On a generic J1939 scan tool, or on the dash of a Freightliner, Kenworth, Peterbilt, International or Volvo chassis, the same fault is shown as SPN 521209 FMI 5 rather than as Cummins code 8219. Cummins INSITE and Calterm show the Cummins number, the SPN / FMI pair and the lamp together.

Fix the file: delete code 8219 from your calibration
from $150

Custom DTC delete, up to 30 codes, $150. Full DPF / EGR / SCR delete with all related codes and derates, $500. Upload your Calterm .xcal, tick the services, pay with PayPal, and the finished file comes back by email and WhatsApp.

Upload your .xcal →
ECFG definition files for your ECM
1,800 files

Cummins ECFG / E2M definitions for CM550, CM552, CM554, CM570, CM800, CM850, CM870, CM871 and more: the fault table, torque, fuelling, boost, EGR, DPF and SCR maps, ready for Calterm or WinOLS. Instant download.

Find your ECFG →

Other Cummins codes on SPN 521209 Connectivity Module

12 other fault codes share this SPN; each one is a different failure mode (FMI) of the same component.

8154 FMI 128155 FMI 138156 FMI 98157 FMI 318221 FMI 38222 FMI 118223 FMI 158224 FMI 168225 FMI 1914279 FMI 1415949 FMI 916313 FMI 9

All codes grouped by SPN →

Related Cummins fault codes

8215 · SPN 521219 FMI 12Connectivity Module Wi-Fi8216 · SPN 521220 FMI 12Connectivity Module Bluetooth8217 · SPN 521221 FMI 12Connectivity Module Accelerometer8218 · SPN 521222 FMI 12Connectivity Module Gyro8221 · SPN 521209 FMI 3Connectivity Module8222 · SPN 521209 FMI 11Connectivity Module8223 · SPN 521209 FMI 15Connectivity Module8224 · SPN 521209 FMI 16Connectivity Module

J1939 failure mode identifiers (FMI)

FMI 5 is highlighted. The FMI is the second half of every J1939 fault and tells you how the component failed; the SPN tells you which component.

FMIMeaning (SAE J1939-73)
0Data valid but above normal operational range - most severe level
1Data valid but below normal operational range - most severe level
2Data erratic, intermittent or incorrect
3Voltage above normal, or shorted to high source
4Voltage below normal, or shorted to low source
5Current below normal or open circuit
6Current above normal or grounded circuit
7Mechanical system not responding or out of adjustment
8Abnormal frequency, pulse width or period
9Abnormal update rate
10Abnormal rate of change
11Root cause not known
12Bad intelligent device or component
13Out of calibration
14Special instructions
15Data valid but above normal operating range - least severe level
16Data valid but above normal operating range - moderately severe level
17Data valid but below normal operating range - least severe level
18Data valid but below normal operating range - moderately severe level
19Received network data in error
20Data drifted high
21Data drifted low
22Reserved for SAE assignment
23Reserved for SAE assignment
24Reserved for SAE assignment
25Reserved for SAE assignment
26Reserved for SAE assignment
27Reserved for SAE assignment
28Reserved for SAE assignment
29Reserved for SAE assignment
30Reserved for SAE assignment
31Condition exists

Questions about code 8219

What does Cummins fault code 8219 mean?

Cummins 8219 is "Connectivity Module - Current Below Normal or Open Circuit". It maps to SPN 521209 FMI 5. The driver or input for Connectivity Module sees less current than it should, which the ECM interprets as an open circuit: a broken wire, an unplugged connector, or an open coil / solenoid.

Which lamp does fault code 8219 turn on?

No lamp: No dash lamp is attached to this code in the Cummins fault table. It is logged in the ECM and shows up in Cummins INSITE (or any J1939 tool reading DM1 / DM2), but on its own it does not light a lamp.

How do I clear or permanently delete Cummins code 8219?

An active code goes inactive on its own once the condition is gone; the inactive record stays in the ECM fault history until it is cleared with Cummins INSITE (or a J1939 tool that supports the DM3 / DM11 clear). If the code keeps coming back because the part is gone, disconnected or not worth repairing, the lasting fix is to disable fault 8219 in the calibration: upload your .xcal to the ECFG Superstore file service, custom DTC delete from $150 (up to 30 codes), full DPF / EGR / SCR delete $500, and flash the returned file with Calterm or INSITE.