Cummins BCW 25.22.38.58 ECFG — ISX (Signature / EGR) CM2100 tuning definition

Cummins BCW 25.22.38.58 ECFG — the ECFG definition file (Cummins DAMOS equivalent) for ISX (Signature / EGR) (Legacy heavy duty / industrial) on the CM2100 ECM: 10,894 named parameters for Calterm / WinOLS tuning — torque, fuelling, boost/VGT, EGR, DPF, SCR/DEF, speed limiter and fault-code tables. Build ID —, created 2011-10-16. Instant download after PayPal checkout.

FormatECFG — Engineering Tool Config File (XML)Product IDBCWSoftware version25.22.38.58ModuleCM2100ECU platformCM2100 / CM2150 PV midrange (2008-2012)EngineISX (Signature / EGR)Application / marketLegacy heavy duty / industrialProgramAFP BCW -C 25.38.00.00 25.22.38.58 CM2180A: PV ISX G EMDBuild ID—Creation date2011-10-16Copyright year2011Parameters10,894 named parameters (<parameter> records)Interface level4.5.4.2First prod cfg file version2003.1.1.0Module part number9999999Boot loader range1.0.4.0 → 1.0.9.9Byte orderBigEndianIndex table address0x00042000Price$100 · instant download after PayPal checkoutHeader CRC502CFile size7.7 MBArchive copies10 copies heldFormatECFG XML (Engineering Tool Config File) · opens in Cummins Calterm; converts to WinOLS map pack / A2L on request
<Engineering_Tool_Config_File version="25.22.38.58" crc="502C"> <compatibility_header> <calibration_version>25.22.38.58</calibration_version> <module_name>CM2100</module_name> <product_id>BCW</product_id> <file_descriptor>Core-II Software Copyright 2011 Cummins Inc. - Cummins Confidential - AFP BCW -C 25.38.00.00 25.22.38.58 CM2180A: PV ISX G EMD</file_descriptor>

What is inside this ECFG

10,894 parameters — 1,548 tables / axes. Counts by area (a parameter can sit in more than one):

751Torque / power
392Fuelling / rail
165Boost / turbo / VGT
247EGR
19DPF / DOC / regen
32SCR / DEF / NOx
799Speed / cruise / idle
678Fault codes / derates
741Sensors / calibration
ParameterAreaDescriptionUnits
ACA_TorqueTorque / powerTorque consumed by all ACAs.N_m
ACA_Torque_MaxTorque / powerTorque value that all ACA can consume at most.N_m
Actual_Eng_Ind_Perc_Trq_Hi_ResTorque / powerParameter is used for broadcasting the high resolution portion of torque that goes with Actual_Eng_Indicated_Perc_Trq on J1939.%
Actual_Eng_Indicated_Perc_TrqTorque / powerParameter is used for broadcasting Actual Engine Percent Torque on the datalink%
Actual_Max_Available_Eng_Perc_TrqTorque / powerParameter is used for broadcasting Actual Maximum Available Engine - Percent Torque (SPN 3357) through datalink. It is the maximum amount of torque that the eng%
Audit_TrailFuelling / railData space reserved in the ECM as a scratchpad for tools to record changes they have requested of the ECM. Reference CES14278 and GTIS requirements.
CBM_Torque_FuelFuelling / railTotal Torque Fueling from CBM_Base - This parameter is used as a trigger in engine brake. Creating here in order to use engine brake functionality. When motormg/stroke
C_ACD_FuelOffsetUserOverrideFuelling / railuseroveride value for Catalyst_Fueling_OffsetNone
C_ACD_RichFuelOffsetPctFuelling / railMass Gas flow offset when in rich offset condition%
C_CBM_TorqueFuelMotoringFuelling / railThe diesel fueling equivalent when in motoring. This is a default constant value.mg/stroke
BPS_BoostEngagedBoost / turbo / VGTHook identifying that Boost Power is actively engaged.None
Boost_Power_Request_SwitchBoost / turbo / VGTDebounced value of the Boost Power Request Switch.None
Boost_PressureBoost / turbo / VGTAbsolute Intake Manifold PressurekPa_G
C_AIP_ChargePress_ToleranceBoost / turbo / VGTSensor error tolerance.kPa
C_BPA_AutoBoostPwrOffTrqDeltaBoost / turbo / VGTAutomatic Boost Power Off Torque Delta. This is used to fulfil the Automatic Boost SRS requirement "b. 'Automatic Boost Power Request' shall be OFF when Net_EnN_m
AIP_EGROT_SensorVoltsEGRExhaust Gas Recirculation Outlet Temperature sensor voltageV
CHRG_EgrPrevSevSdReqEGRThe previous engine protection engine state request from the EGR severity based shutdown feature. 0 = Shutdown w/o restart limit 1 = Run 2 = Shutdown approachiNone
CHRG_EgrPrevSpdDrtCalcEGRThis is the previous EPD calculated speed derate value for the EGR Orifice Temperature sensor.RPM
CHRG_EgrPrevSpdSdReqEGRThe previous engine protection engine state request from the EGR speed shutdown feature. 0 = Shutdown w/o restart limit 1 = Run 2 = Shutdown approaching w/o reNone
CHRG_EgrPrevTrqDrtCalcEGRThis is the previous EPD calculated torque derate value for the EGR Orifice Temperature sensor.N_m
C_DLC_Disable_Regen_LSI_OffsetDPF / DOC / regenPR/CR DB_G00130215 - If the target speed for a speed control command is greater than LSI_ReferenceSpd plus this value, then DLC_Prevent_Regen will be set.RPM
C_DLC_Prevent_Regen_TSC1_AddrDPF / DOC / regenList of addresses of TSC1 controlling devices for which stationary regen will be prohibited and LSI max limit will be lowered. All unused elements shall be fil
C_DPF_Lamp_User_SelectableDPF / DOC / regenThis is a required parameterwhich indicates to the tool whether the DPF Lamp feature is available for selection by the tool.None
C_J39_Eng_BackPress_Soot_AxisDPF / DOC / regenX-Axis for C_J39_Eng_BackPress_Torque_Tbl. The input for this axis is V_SFP_mg_Soot_Load_Comb .
C_J39_PT_Regen_Force_Switch_Port_IDDPF / DOC / regenPort on which J39_PT_Regen_Force_Switch in the Cab 1 Message should be received.None
C_ABS_Rmt_Throttle_Def_GovSCR / DEF / NOxThis parameter determines what is the default governor when remote throttle is active and T_SwitchableGovernorEnable is disabled. This would eliminate the need
C_DIP_DiscreteCoolantLevelDelaySCR / DEF / NOxThe delay before engine coolant detected switches affect the Coolant Level Low Error.s
C_DL_EC_Def_TqCrv_NumberSCR / DEF / NOxThe default torque curve index number to use for J1939 Engine Configuration message speed points when the torque curve index returned by the Machine Manager is None
C_J1939_NOx_Aft_SystemSCR / DEF / NOxCalibration used to indicate what type of NOx Aftertreatment System is present. 0=none 1=Catalyst 2=AdsorberNone
C_J39_Aux_Discrete_Input_1_Port_IDSCR / DEF / NOxPort on which J39_Aux_Discrete_Input_1 is allowed to be received.None
ACD_IdleTimerSpeed / cruise / idleTimer used to check if engine is idlings
AFW_Idle_SpeedSpeed / cruise / idleThe idle speed calculated by the Alternator Failure warning featureRPM
APP_On_IdleSpeed / cruise / idleIndicates whether or not the Accelerator is in the Idle position. Value is determined by either idle validation switches or Secondary_Accel_Pedal_Pos, dependinNone
AP_Low_Idle_SwitchSpeed / cruise / idleSwitch signal which indicates whether the accelerator pedal low idle switch is opened or closed. 0x00 Accelerator pedal not in low idle condition 0x01 AccelNone
Accelerator_Governor_SwitchSpeed / cruise / idleDebounced value of Accelerator Governor Switch physical input. When TRUE, this input causes Selected_Governor to toggle from "ABS" to "ABT" or vice versa depeNone
AIP_CIL_IR2_FaultCountFault codes / deratesCIL IR Abnormal Update Rate Diagnostic - Number of fault conditions that are active before logging a fault code. This is a monitor for which calibration has becounts
AIP_CIL_IR2_FaultCounterFault codes / deratesCIL IR Abnormal Update Rate Diagnostic - Keeps track of the number of fault conditions that have occurred during this engine operation. This value can be countcounts
CAGT_Block_Fault_CodesFault codes / deratesArray of fault codes to be blocked. Fault codes can be found in CES14602 specification. Size of this array and hence the maximum number of faults that can be bl
CAGT_ENG_OBDAD_Data_Reset_PtrFault codes / deratesfuntion pointer to service OBDAD_Data_Reset of OBD-AdministratorNone
CAGT_FreezeActFaultCodesFlagFault codes / deratesIf it is TRUE, it freezes the active fault codes, and if it is FALSE, active fault codes are processed normal.None
AIP_ACT_SensorVoltsSensors / calibrationACT sensor power supply voltageV
AIP_AFT_SensorVoltsSensors / calibrationAir Flow Temperature sensor voltageV
AIP_CIL_SensorVoltsSensors / calibrationCIL sensor power supply voltageV
AIP_CIP_SensorVoltsSensors / calibrationCompressor Inlet Pressure sensor voltageV
AIP_CIRH_SensorVoltsSensors / calibrationCompressor inlet relative humidity sensor voltageV

Sample of named calibration parameters with their Cummins descriptions. The full ECFG lists every parameter with ITN address, data type, scaling, limits and units.