ECFG Superstore › BJW › 42.30.30.22
MY ACCOUNT / MY FILES →

Cummins BJW 42.30.30.22 ECFG — ISF4.5 CM2620 tuning definition

Cummins BJW 42.30.30.22 ECFG — the ECFG definition file (Cummins DAMOS equivalent) for ISF4.5 (Medium duty on-highway) on the CM2620A ECM: 31,794 named parameters for Calterm / WinOLS tuning — torque, fuelling, boost/VGT, EGR, DPF, SCR/DEF, speed limiter and fault-code tables. Build ID 210060, created 2018-05-15. Instant download after PayPal checkout.

FormatECFG — Engineering Tool Config File (XML)Product IDBJWSoftware version42.30.30.22ModuleCM2620AECU platformCM2620A Euro VI midrangeEngineISF4.5Application / marketMedium duty on-highwayModel year2020EmissionsEPA13ProgramMD-EU-ISF-MY20-CM2620-C35-V42.30.30.22Build ID210060Creation date2018-05-15Copyright year2018Parameters31,794 named parameters (<parameter> records)Interface level4.6.0.0First prod cfg file version2003.1.1.0Module part number9999999Boot loader range2.4.5.0 → 2.4.6.0Byte orderBigEndianIndex table address0x00842000MSNR config id000000E4Price$200 · instant download after PayPal checkoutHeader CRC4C86File size21.6 MBArchive copies4 copies heldFormatECFG XML (Engineering Tool Config File) · opens in Cummins Calterm; converts to WinOLS map pack / A2L on request
<Engineering_Tool_Config_File version="42.30.30.22" crc="4C86"> <compatibility_header> <calibration_version>42.30.30.22</calibration_version> <module_name>CM2620A</module_name> <product_id>BJW</product_id> <file_descriptor>Core-II Software Copyright 2018 Cummins Inc. - Cummins Confidential - MD-EU-ISF-MY20-CM2620-C35-V42.30.30.22 - Build ID - 210060</file_descriptor>

What is inside this ECFG

31,794 parameters — 2,636 tables / axes. Counts by area (a parameter can sit in more than one):

1,196Torque / power
1,336Fuelling / rail
684Boost / turbo / VGT
1,424EGR
1,733DPF / DOC / regen
3,588SCR / DEF / NOx
1,217Speed / cruise / idle
1,901Fault codes / derates
1,019Sensors / calibration
ParameterAreaDescriptionUnits
ACA_TorqueTorque / powerTorque consumed by all ACAs.N_m
ACA_Torque_MaxTorque / powerTorque value that all ACA can consume at most.N_m
ACA_Torque_ReserveTorque / powerReserve torque consumed by all ACAs.N_m
Actual_Eng_Ind_Perc_Trq_Hi_ResTorque / powerParameter is used for broadcasting the high resolution portion of torque that goes with Actual_Eng_Indicated_Perc_Trq on J1939.%
Actual_Eng_Indicated_Perc_TrqTorque / powerParameter is used for broadcasting Actual Engine Percent Torque on the datalink%
AH_Fuel_Derate_LatchFuelling / rail[AHFLDRLA] Indicates turbo overspeed protection fuel derate [From 02 -- Units: UNITLESS Size:2 Digits:0 Signed:U Scalar:1] [Jims comp:{EMM}]None
AIC_ct_LowFuelCvrgFuelling / railThis is the count that indicates the number of cells (Pressure/Fuel points) covered for each injector in the low Fueling Coverage Map. Injector notation is in
AIC_q_MeasFuelingFuelling / railThe actual fueling commanded by IFC during an AES or IFM test data collection.mg/stroke
AIC_q_MotoringMsmtTargetFuelFuelling / railThe target fueling array for a motoring measurement. It has 3 elements so that in the future it can support up to 3 pulses, but currently only one pulse is supp
AIC_q_TargetFuelArrayFuelling / railFueling array of the current pressure bucket
AIF_AlphaAAPTurboProtBoost / turbo / VGTAlpha contribution from ambient air pressure logic of the alpha algoirthm (boolean 0 or 1)None
AIP_ChargePress_Override_ValueBoost / turbo / VGTCharge Pressure override valuekPa
AIP_Charge_Tmptr_Override_ValueBoost / turbo / VGTCharge_Tmptr override value when T_AIP_CHT_User_Override is set..Deg_C
BPS_BoostEngagedBoost / turbo / VGTHook identifying that Boost Power is actively engaged. 1 = off (base curve) 2 = boost curve 3 = burst curveNone
BSM_ChargePress_Hi_EnabledBoost / turbo / VGTFlag for charge high pressure monitor enabled in BSMNone
AIP_EGRDeltaPress_Override_ValEGREGR Delta Press user override value when T_AIP_EGRDeltaPress_Ovrd_En is set.kPa
AIP_EGROrificePress_Ovrd_ValEGREGR Orifice Pressure override valuekPa_A
AIP_EGROrificeTmptr_Ovrd_ValEGREGR Orifice Temperature user override value when T_AIP_EGROrificeTmptr_Ovrd_En is set.Deg_C
APC_r_PressNegRateLimitEGRPressure rate limit for decreasing accumulator pressure commands (>12.5 bar/sec).Bar/Sec
CBL_EGR_Frac_CmdEGREGR fraction command passed to Charge Manager from Combustion Manager BaseNone
CAGT_SS_Inh_ATM_Regen_ActiveDPF / DOC / regenIndicates whether DPF Regeneration is active. This parameter looks at bit 0 of the bit mapped data J39_PrvntFlngInhbtRsn_BitMap.None
C_ABT_Regen_BrkTrq_Falling_RateDPF / DOC / regenDesigned for power systems applications only. Falling rate from partial braking torque (1) to full braking torque (0).None
C_ABT_Regen_BrkTrq_Rising_RateDPF / DOC / regenDesigned for power systems applications only. Rsing rate from full braking torque (0) to partial braking torque (1).None
C_AIM_DOC_In_DualPullupEnblDPF / DOC / regenFlag enabling the dual pullup for the thermistorNone
C_AIM_DOC_Out_DualPullupEnblDPF / DOC / regenFlag enabling the dual pullup for the thermistorNone
AC_Discrete_OutputSCR / DEF / NOxParameter indicates the status of AC Driver 1- AC driver is turned ON 0 - AC driver is turned OFFNone
AIF_AlphaSCRSCR / DEF / NOxAlpha request from SCR Bed Temp section of the Alpha algorithm (boolean 0 or 1)None
APC_ti_LPrsCrankClearErrSCR / DEF / NOxTimer to clear a fuel pressure low cranking fault condition exists.s
CBM_Dosing_Prohibit_EGRSCR / DEF / NOxProhibits EGR Control when In-cylinder dosing is activeNone
CBM_NOx_Humidity_CorrSCR / DEF / NOxNOx humidity correction factorNone
AFW_Idle_SpeedSpeed / cruise / idleThe idle speed calculated by the Alternator Failure warning featureRPM
AIF_AlphaGovernorSpeed / cruise / idleresult of On Governor logic (boolean 0 or 1)None
APP_On_IdleSpeed / cruise / idleIndicates whether or not the Accelerator is in the Idle position. Value is determined by either idle validation switches or Secondary_Accel_Pedal_Pos, dependinNone
AP_Low_Idle_SwitchSpeed / cruise / idleSwitch signal which indicates whether the accelerator pedal low idle switch is opened or closed. 0x00 Accelerator pedal not in low idle condition 0x01 AccelNone
Accelerator_Governor_SwitchSpeed / cruise / idleDebounced value of Accelerator Governor Switch physical input. When TRUE, this input causes Selected_Governor to toggle from "ABS" to "ABT" or vice versa depeNone
ADD_ct_InmtPwmOffFaultFault codes / deratesdiagnostic counter for IMV driver intermittent off-state faultcounts
ADD_ct_InmtPwmOffNoFaultFault codes / deratesnumber of no faults between intermittent off-state fault countscounts
ADD_ct_InmtPwmOnFaultFault codes / deratesdiagnostic counter for IMV driver intermittent on-state faultcounts
ADD_ct_InmtPwmOnNoFaultFault codes / deratesnumber of no faults between intermittent on-state fault countscounts
ADD_ct_LatchOffFault1Fault codes / deratesdiagnostic counters for FSR latch off fault bitscounts
AC_PressureSensors / calibrationThe linearized and filtered analog air conditioner head pressure gage value.kPa
AC_Pressure_Error_CountsSensors / calibrationelapsed AC Pressure error count durationNone
AC_Pressure_LearnedSensors / calibrationStatus indicating AC pressure sensor is in range.None
AC_Pressure_No_High_OR_Low_FltsSensors / calibrationStatus indicating there are no AC Pressure High or Low Error faults. TRUE - If both AC Pressure High and Low Error faults are not there FALSE if either AC PreNone
AC_Pressure_Not_HighSensors / calibrationStatus indicating AC Pressure is not higher than the threshold for AC to switch On TRUE - If AC Pressure is less than the threshold FALSE - If AC Pressure is None

Sample of named calibration parameters with their Cummins descriptions. The full ECFG lists every parameter with ITN address, data type, scaling, limits and units.

Other BJW versions (1)

42.60.20.24ECFG · CM2670 · 2019-01-13
Buy & download
Loading checkout…
Custom file service on your .xcal: DTC / full delete, extra HP, VGT delete