MY ACCOUNT / MY FILES →Cummins E2I 11.1.0.18 ECFG — QSB4.5 / QSB5.9 / QSB6.7 industrial CM850 tuning definition
Cummins E2I 11.1.0.18 ECFG — the ECFG definition file (Cummins DAMOS equivalent) for QSB4.5 / QSB5.9 / QSB6.7 industrial (Industrial / off-highway) on the CM850 ECM: 7,835 named parameters for Calterm / WinOLS tuning — torque, fuelling, boost/VGT, EGR, DPF, SCR/DEF, speed limiter and fault-code tables. Build ID —, created —. Instant download after PayPal checkout.
FormatECFG — Engineering Tool Config File (XML)Product ID
E2ISoftware version11.1.0.18ModuleCM850ECU platformCM850 / CM870 Core-II (2003-2007)EngineQSB4.5 / QSB5.9 / QSB6.7 industrialApplication / marketIndustrial / off-highwayProgramMidrange Industrial II - P11.1.0.18Build ID—Creation date—Copyright year2005Parameters7,835 named parameters (<parameter> records)Interface level4.5.2.0First prod cfg file version2003.1.1.0Module part number3954430Boot loader range4.6.0.1 → 4.9.9.9Byte orderBigEndianIndex table address0x00500000Price$100 · instant download after PayPal checkoutHeader CRC9C60File size5.6 MBArchive copies15 copies heldFormatECFG XML (Engineering Tool Config File) · opens in Cummins Calterm; converts to WinOLS map pack / A2L on request<Engineering_Tool_Config_File version="11.1.0.18" crc="9C60">
<compatibility_header>
<calibration_version>11.1.0.18</calibration_version>
<module_name>CM850</module_name>
<product_id>E2I</product_id>
<file_descriptor>Core-II Software Copyright 2005 Cummins Inc. - Cummins Confidential - Midrange Industrial II - P11.1.0.18</file_descriptor>
What is inside this ECFG
7,835 parameters — 1,114 tables / axes. Counts by area (a parameter can sit in more than one):
399Torque / power
390Fuelling / rail
345Boost / turbo / VGT
253EGR
31SCR / DEF / NOx
480Speed / cruise / idle
344Fault codes / derates
520Sensors / calibration
| Parameter | Area | Description | Units |
|---|---|---|---|
| Actual_Eng_Indicated_Perc_Trq | Torque / power | Parameter is used for broadcasting Actual Engine Percent Torque on the datalink | % |
| All_Powerdown_Data_Lost_Run | Torque / power | Flag indicating if engine should be run if All_Powerdown_Data_Lost_Error is TRU | HEX |
| Boost_Power_Request_Switch | Torque / power | Debounced value of the Boost Power Request Switch. | None |
| CBP_Combustion_Torque | Torque / power | Engine Torque from CBP_Adj_Total_Fueling & Filtered_Engine_Speed [From 02 -- Units: FT*LB Size:2 Digits:0 Signed:S Scalar:0.5] [Jims comp:{CBM}] | N_m |
| CBP_Net_Combustion_Torque | Torque / power | Net Combustion Torque [From 02 -- Units: FT*LB Size:2 Digits:1 Signed:S Scalar:0.5] [Jims comp:{CBM}] | N_m |
| AH_Fuel_Derate_Latch | Fuelling / rail | [AHFLDRLA] Indicates turbo overspeed protection fuel derate [From 02 -- Units: UNITLESS Size:2 Digits:0 Signed:U Scalar:1] [Jims comp:{EMM}] | None |
| AIF_AlphaFuelRate | Fuelling / rail | Alpha request from fuel rate section of the Alpha algorithm (boolean 0 or 1) [From 02 -- Units: UNITLESS Size:2 Digits:0 Signed:U Scalar:1] [Jims comp:{EMM | None |
| AIF_FuelRate | Fuelling / rail | [APFLRTAP] Fuel Rate algorithm as determined by the alpha determination algorithm [From 02 -- Units: UNITLESS Size:2 Digits:0 Signed:U Scalar:1] [Jims | kg/hr |
| Audit_Trail | Fuelling / rail | Data space reserved in the ECM as a scratchpad for tools to record changes they have requested of the ECM. Reference CES14278 and GTIS requirements. The audit | |
| CBL_Fuel_Cmd | Fuelling / rail | Fuel command after imposing combustion limits [From 02 -- Units: MG/STROKE Size:2 Digits:2 Signed:U Scalar:0.067934782] [Jims comp:{CBM}] | mg/stroke |
| AIF_AlphaAAPTurboProt | Boost / turbo / VGT | [APAAPRSS] Alpha contribution from ambient air pressure logic of the alopha algoirthm (boolean 0 or 1) [From 02 -- Units: UNITLESS Size:2 Digits:2 Sign | None |
| BPS_BoostEngaged | Boost / turbo / VGT | Hook identifying that Boost Power is actively engaged. | None |
| BVC_s_LowBoostVoltage | Boost / turbo / VGT | low boost voltage indicator | None |
| Boost_Pressure | Boost / turbo / VGT | Linearized and filtered analog boost pressure | kPa_G |
| CBO_Charge_Aggressiveness_Ref | Boost / turbo / VGT | Charge aggressive reference after off-nominal compensation [From 02 -- Units: UNITLESS Size:2 Digits:3 Signed:U Scalar:0.00012207] [Jims comp:{CBM}] | None |
| CBL_EGR_Frac_Cmd | EGR | EGR fraction command passed to Charge Manager from Combustion Manager [From 02 -- Units: UNITLESS Size:2 Digits:3 Signed:U Scalar:0.00012207] [Jims co | None |
| CBR_Base_Chi_EGR_Frac_Cmd | EGR | EGR Fraction derived from chi_base [From 02 -- Units: UNITLESS Size:2 Digits:3 Signed:U Scalar:0.00012207] [Jims comp:{CBM}] | None |
| CBR_EGR_Frac_Ref | EGR | EGR fraction reference, unlimited and uncompensated [From 02 -- Units: UNITLESS Size:2 Digits:3 Signed:U Scalar:0.00012207] [Jims comp:{CBM}] | None |
| CBR_EGR_Off | EGR | EGR is off by EMM permission or user override | None |
| CHH_EGR_System_Failure | EGR | True/False indicator of an EGR system failure | None |
| CBO_bsNOx | SCR / DEF / NOx | CBR_NOx_Target_Ref adjusted for off-nominal conditions [From 02 -- Units: G/HP*HR Size:2 Digits:3 Signed:U Scalar:0.000244140625] [Jims comp:{CBM}] | g/HP*hr |
| CBR_NOx_Target_Ref | SCR / DEF / NOx | NOx target reference [From 02 -- Units: G/HP*HR Size:2 Digits:3 Signed:U Scalar:0.000488281] [Jims comp:{CBM}] | g/HP*hr |
| C_ACD_Ind_Def_Intermediate_Val | SCR / DEF / NOx | high throttle % used by industrial throttle default | % |
| C_ACD_Ind_Def_Low_Val | SCR / DEF / NOx | low throttle % to go to used by industrial throttle default | % |
| C_ACD_Ind_Def_Ramp_Rate | SCR / DEF / NOx | throttle ramp rate used by industrial throttle default | %/s |
| AIF_AlphaGovernor | Speed / cruise / idle | [APGVAP] result of On Governor logic (boolean 0 or 1) [From 02 -- Units: UNITLESS Size:2 Digits:0 Signed:U Scalar:1] [Jims comp:{EMM}] | None |
| AIP_PTO_Var_Switch_Ovrd_Val | Speed / cruise / idle | User override value for PTO_Variable_Switch | None |
| AP_Low_Idle_Switch | Speed / cruise / idle | Switch signal which indicates whether the accelerator pedal low idle switch is opened or closed. 0x00 Accelerator pedal not in low idle condition 0x01 Accel | None |
| Alternate_Idle_Switch | Speed / cruise / idle | Debounced value of Alternate Idle Switch physical input. | None |
| Auto_Idle_Override_Switch | Speed / cruise / idle | Debounced value of Auto Idle Override Switch physical input. | None |
| AMB_AirPressDefault | Fault codes / derates | Air_Press_Sensor global default value [From 02 -- Units: IN_HG Size:2 Digits:2 Signed:U Scalar:0.0159064138077] [Jims comp:{EMM}] | kPa |
| CFTR_Fault_2_Lamp_Map | Fault codes / derates | A one dimensional array whose index is the same as error_index. It stores the lamp to light for each error. This design supports up to 8 lamps. 0000 0000 00 | |
| CFTR_Fault_Count_Table | Fault codes / derates | This array contains the current fault count for each fault that is currently active in the system. The fault count for each error is incremented each time the | |
| CFTR_Fault_Status_Mismatch_Ctr | Fault codes / derates | This indicates that how many times there was mismatch in the CFTR_Fault_Status_Table.Every error in the CFTR_ErrorIndexTable is searched in the ECM_Active_Error | None |
| CFTR_Fault_Status_Table | Fault codes / derates | This array contains the current error state for each fault that is currently active in the system. The index into this array is associated with a system error | |
| AMB_AirPressSensorPriority | Sensors / calibration | Air_Pressure_Sensor mux override priority [From 02 -- Units: UNITLESS Size:1 Digits:0 Signed:U Scalar:1] [Jims comp:{EMM}] | None |
| APC_v_DslPrsSensor | Sensors / calibration | Diesel Rail Pressure Sensor Voltage (ref to 5V) | V |
| Accel_Position_Sensor_Volts | Sensors / calibration | sensor voltage detected by the ECM. | V |
| Accumulator_Pressure | Sensors / calibration | Accumulator Pressure from fixed rate processing | bar_A |
| Air_Conditioner_Pressure_Switch | Sensors / calibration | Indicates the value of Air Conditioner Pressure Switch. A value of 0 or 1 indicates the position of the switch. A value of 2 or greater indicates an invalid s | None |
Sample of named calibration parameters with their Cummins descriptions. The full ECFG lists every parameter with ITN address, data type, scaling, limits and units.