ECFG Superstore › Cummins fault codes › 2876

Cummins fault code2876 · Turbocharger 1 Compressor Intake Temperature

Turbocharger 1 Compressor Intake Temperature - Data Valid But Below Normal Operating Range - Most Severe Level

Fault code2876 Cummins fault code as shown in INSITE / CaltermSPN1172 · Turbocharger 1 Compressor Intake TemperatureFMI1 Data valid but below normal operational range - most severe levelOBD codenone (J1939 only)LampRed STOP lampCummins textTurbocharger 1 Compressor Intake Temperature - Data Valid But Below Normal Operating Range - Most Severe LevelFailure modeData Valid But Below Normal Operating Range - Most Severe Level

What Cummins code 2876 means

The reading for Turbocharger 1 Compressor Intake Temperature is believed to be correct, but it has fallen below the lowest limit in the calibration. This is the most severe of the three "below range" levels (FMI 17, 18 and 1), so the ECM is reporting a real operating problem rather than a wiring fault.

It turns on the red STOP ENGINE lamp. Cummins classes this as a fault that can damage the engine or aftertreatment if ignored: stop as soon as it is safe to do so. Many calibrations also apply an engine-protection derate while the fault is active.

On a generic J1939 scan tool, or on the dash of a Freightliner, Kenworth, Peterbilt, International or Volvo chassis, the same fault is shown as SPN 1172 FMI 1 rather than as Cummins code 2876. Cummins INSITE and Calterm show the Cummins number, the SPN / FMI pair and the lamp together.

Fix the file: delete code 2876 from your calibration
from $150

Custom DTC delete, up to 30 codes, $150. Full DPF / EGR / SCR delete with all related codes and derates, $500. Upload your Calterm .xcal, tick the services, pay with PayPal, and the finished file comes back by email and WhatsApp.

Upload your .xcal →
ECFG definition files for your ECM
1,800 files

Cummins ECFG / E2M definitions for CM550, CM552, CM554, CM570, CM800, CM850, CM870, CM871 and more: the fault table, torque, fuelling, boost, EGR, DPF and SCR maps, ready for Calterm or WinOLS. Instant download.

Find your ECFG →

Other Cummins codes on SPN 1172 Turbocharger 1 Compressor Intake Temperature

18 other fault codes share this SPN; each one is a different failure mode (FMI) of the same component.

617 FMI 16691 FMI 3 · P1193692 FMI 4 · P1192693 FMI 2 · P11912877 FMI 183369 FMI 93371 FMI 194833 FMI 156221 FMI 56222 FMI 66223 FMI 146544 FMI 36545 FMI 46546 FMI 27437 FMI 217438 FMI 207861 FMI 10 · P2B7113794 FMI 10

All codes grouped by SPN →

Related Cummins fault codes

2872 · SPN 520382 FMI 31High Temperature (HT) Cooling Circuit Current Driver Breaker2873 · SPN 520383 FMI 6Aftercooler Cooling Circuit Current Driver2874 · SPN 520383 FMI 5Aftercooler Cooling Circuit Current Driver2875 · SPN 520383 FMI 31Aftercooler Cooling (LT) Circuit Current Driver Breaker2877 · SPN 1172 FMI 18Turbocharger 1 Compressor Intake Temperature2878 · SPN 4097 FMI 7Aftertreatment Fuel Drain Valve2879 · SPN 4097 FMI 2Aftertreatment Fuel Drain Valve2881 · SPN 3480 FMI 17Aftertreatment Fuel Pressure Sensor

J1939 failure mode identifiers (FMI)

FMI 1 is highlighted. The FMI is the second half of every J1939 fault and tells you how the component failed; the SPN tells you which component.

FMIMeaning (SAE J1939-73)
0Data valid but above normal operational range - most severe level
1Data valid but below normal operational range - most severe level
2Data erratic, intermittent or incorrect
3Voltage above normal, or shorted to high source
4Voltage below normal, or shorted to low source
5Current below normal or open circuit
6Current above normal or grounded circuit
7Mechanical system not responding or out of adjustment
8Abnormal frequency, pulse width or period
9Abnormal update rate
10Abnormal rate of change
11Root cause not known
12Bad intelligent device or component
13Out of calibration
14Special instructions
15Data valid but above normal operating range - least severe level
16Data valid but above normal operating range - moderately severe level
17Data valid but below normal operating range - least severe level
18Data valid but below normal operating range - moderately severe level
19Received network data in error
20Data drifted high
21Data drifted low
22Reserved for SAE assignment
23Reserved for SAE assignment
24Reserved for SAE assignment
25Reserved for SAE assignment
26Reserved for SAE assignment
27Reserved for SAE assignment
28Reserved for SAE assignment
29Reserved for SAE assignment
30Reserved for SAE assignment
31Condition exists

Questions about code 2876

What does Cummins fault code 2876 mean?

Cummins 2876 is "Turbocharger 1 Compressor Intake Temperature - Data Valid But Below Normal Operating Range - Most Severe Level". It maps to SPN 1172 FMI 1. The reading for Turbocharger 1 Compressor Intake Temperature is believed to be correct, but it has fallen below the lowest limit in the calibration. This is the most severe of the three "below range" levels (FMI 17, 18 and 1), so the ECM is reporting a real

Which lamp does fault code 2876 turn on?

Red STOP lamp: It turns on the red STOP ENGINE lamp. Cummins classes this as a fault that can damage the engine or aftertreatment if ignored: stop as soon as it is safe to do so. Many calibrations also apply an engine-protection derate while the fault is active.

How do I clear or permanently delete Cummins code 2876?

An active code goes inactive on its own once the condition is gone; the inactive record stays in the ECM fault history until it is cleared with Cummins INSITE (or a J1939 tool that supports the DM3 / DM11 clear). If the code keeps coming back because the part is gone, disconnected or not worth repairing, the lasting fix is to disable fault 2876 in the calibration: upload your .xcal to the ECFG Superstore file service, custom DTC delete from $150 (up to 30 codes), full DPF / EGR / SCR delete $500, and flash the returned file with Calterm or INSITE.

← All Cummins fault codes  ·  XCAL file service  ·  ECFG Superstore