ECFG Superstore › BHQ › 52.24.0.54
MY ACCOUNT / MY FILES →

Cummins BHQ 52.24.0.54 ECFG — ISB6.7 Vulture CM2450 tuning definition

Cummins BHQ 52.24.0.54 ECFG — the ECFG definition file (Cummins DAMOS equivalent) for ISB6.7 Vulture (Chrysler / Ram pickup) on the CM24xx ECM: 33,561 named parameters for Calterm / WinOLS tuning — torque, fuelling, boost/VGT, EGR, DPF, SCR/DEF, speed limiter and fault-code tables. Build ID 265546, created 2023-02-10. Instant download after PayPal checkout.

FormatECFG — Engineering Tool Config File (XML)Product IDBHQSoftware version52.24.0.54ModuleCM24xxECU platformCM2450A / CM2450B / CM2450E (EPA21, 2018+)EngineISB6.7 VultureApplication / marketChrysler / Ram pickupModel year2024EmissionsEPA21ProgramCHR-PU-SO-MY24-V52.24.00.54-PS - Build ID - 265546Build ID265546Creation date2023-02-10Copyright year—Parameters33,561 named parameters (<parameter> records)Interface level4.6.0.0First prod cfg file version2003.1.1.0Module part number9999999Boot loader range2.4.3.0 → 2.4.8.2Byte orderBigEndianIndex table address0x00842000MSNR config id000001D1Price$500 · instant download after PayPal checkoutHeader CRC3C12File size21.7 MBArchive copies1 copy heldFormatECFG XML (Engineering Tool Config File) · opens in Cummins Calterm; converts to WinOLS map pack / A2L on request
<Engineering_Tool_Config_File version="52.24.0.54" crc="3C12"> <compatibility_header> <calibration_version>52.24.0.54</calibration_version> <module_name>CM24xx</module_name> <product_id>BHQ</product_id> <file_descriptor>CHR-PU-SO-MY24-V52.24.00.54-PS - Build ID - 265546</file_descriptor>

What is inside this ECFG

33,561 parameters — 2,318 tables / axes. Counts by area (a parameter can sit in more than one):

1,077Torque / power
1,334Fuelling / rail
908Boost / turbo / VGT
1,295EGR
1,832DPF / DOC / regen
3,538SCR / DEF / NOx
838Speed / cruise / idle
2,366Fault codes / derates
1,054Sensors / calibration
ParameterAreaDescriptionUnits
ACA_TorqueTorque / powerTorque consumed by all ACAs.N_m
ACA_Torque_MaxTorque / powerTorque value that all ACA can consume at most.N_m
ALTC_Load_TorqueTorque / powerRequested Torque FilteredN_m
Actual_Eng_Ind_Perc_Trq_Hi_ResTorque / powerParameter is used for broadcasting the high resolution portion of torque that goes with Actual_Eng_Indicated_Perc_Trq on J1939.%
Actual_Eng_Indicated_Perc_TrqTorque / powerParameter is used for broadcasting Actual Engine Percent Torque on the datalink%
AH_Fuel_Derate_LatchFuelling / rail[AHFLDRLA] Indicates turbo overspeed protection fuel derate [From 02 -- Units: UNITLESS Size:2 Digits:0 Signed:U Scalar:1] [Jims comp:{EMM}]None
AIC_ct_LowFuelCvrgFuelling / railThis is the count that indicates the number of cells (Pressure/Fuel points) covered for each injector in the low Fueling Coverage Map. Injector notation is in
AIC_q_MeasFuelingFuelling / railThe actual fueling commanded by IFC during an AES or IFM test data collection.mg/stroke
AIC_q_TargetFuelArrayFuelling / railFueling array of the current pressure bucket
AIC_s_FuelingRegionFuelling / railThe fueling region associated with the commanded total fueling: 0 = NO_FUELING 1 = LOW_FUELING 2 = INTERPOLATION 3 = MID_FUELING 4 = HIGH_FUNone
ACAA_ALTC_CD_ChargeErrBoost / turbo / VGTCapability for charge errs
ACAA_ALTC_CD_ChargeHighBoost / turbo / VGTCapability for charge system high errs
ACAA_ALTC_CD_ChargeLowBoost / turbo / VGTCapability data for charging system low err.s
AFM_Filtered_Compressor_PressureBoost / turbo / VGTFiltered value of ambient air pressure.kPa
AGS_Boost_ModeBoost / turbo / VGTThis data is set to 1 when the Vehicle Active Grill Shutter is mechanically stuck after any calibration attempt at an ambient temperature below C_AGS_Boost_AAT_None
AFM_Regression_StateEGRIndicates Regression data for current flow range has not reached limit yetNone
AIP_EGROrificeTmptr_Ovrd_ValEGREGR Orifice Temperature user override value when T_AIP_EGROrificeTmptr_Ovrd_En is set.Deg_C
CBL_EGR_Frac_CmdEGREGR fraction command passed to Charge Manager from Combustion Manager BaseNone
CBL_EGR_Frac_Cmd_EnableEGREnable for EGR Fraction Command Processing in Charge Manager BaseNone
CBM_Dosing_Prohibit_EGREGRProhibits EGR Control when In-cylinder dosing is activeNone
AGS_AT_Regen_CmdDPF / DOC / regenActive Grill Shutter after-treatment regen control value when conditions of regen mode are met. (open, highest flow value is 100% and closed lowest flow value i%
AGS_AT_Regen_PriDPF / DOC / regenActive grill shutter runtime command priority for after-treatment regen mode. Runtime priority in decision command logic. {0 will disable / do nothing}HEX
CANC_DPF_Percent_DL_ValueDPF / DOC / regenDPF Full Percent value transmitted on the data link. It has already been scaled to 10% increments.None
CANC_Dpf_Def_WrnStatDPF / DOC / regenState of the current warning receive on the datalink, 0 No warning, 1 Non-Diesel warning, 2 Interruptable warning, 3 DPF warning, 4 DEF Warning, 15 SNANone
CANC_Man_Regen_Start_FlagDPF / DOC / regenDPF Manual regen start flag.None
AC_Discrete_OutputSCR / DEF / NOxParameter indicates the status of AC Driver 1- AC driver is turned ON 0 - AC driver is turned OFFNone
AIF_AlphaSCRSCR / DEF / NOxAlpha request from SCR Bed Temp section of the Alpha algorithm (boolean 0 or 1)None
APC_ti_LPrsCrankClearErrSCR / DEF / NOxTimer to clear a fuel pressure low cranking fault condition exists.s
Active100HR_NOx_Mass_Engine_OutSCR / DEF / NOxNOx Mass - Engine Out (Active) shall display the accumulated NOx mass produced by the engine while all NOx sensors are active. Calculated using the following eq
Active100HR_NOx_Mass_TailpipeSCR / DEF / NOxNOx Mass - Tailpipe (Active) shall display the accumulated NOx mass emitted at the vehicle tailpipe while all NOx sensors are active. Calculated using the follo
AIF_AlphaGovernorSpeed / cruise / idleresult of On Governor logic (boolean 0 or 1)None
APP_On_IdleSpeed / cruise / idleIndicates whether or not the Accelerator is in the Idle position. Value is determined by either idle validation switches or Secondary_Accel_Pedal_Pos, dependinNone
AP_Low_Idle_SwitchSpeed / cruise / idleSwitch signal which indicates whether the accelerator pedal low idle switch is opened or closed. 0x00 Accelerator pedal not in low idle condition 0x01 AccelNone
Accelerator_Governor_SwitchSpeed / cruise / idleDebounced value of Accelerator Governor Switch physical input. When TRUE, this input causes Selected_Governor to toggle from "ABS" to "ABT" or vice versa depeNone
Active100HR_GHG_EngIdleFuelCnsmSpeed / cruise / idleEngine Idle Fuel Consumption (Active) shall accumulate the calculated amount of fuel injected into the engine only during idle conditions: while the propulsion L
ADD_ct_InmtPwmOffFaultFault codes / deratesdiagnostic counter for IMV driver intermittent off-state faultcounts
ADD_ct_InmtPwmOffNoFaultFault codes / deratesnumber of no faults between intermittent off-state fault countscounts
ADD_ct_InmtPwmOnFaultFault codes / deratesdiagnostic counter for IMV driver intermittent on-state faultcounts
ADD_ct_InmtPwmOnNoFaultFault codes / deratesnumber of no faults between intermittent on-state fault countscounts
ADD_ct_LatchOffFault1Fault codes / deratesdiagnostic counters for FSR latch off fault bitscounts
AC_PressureSensors / calibrationThe linearized and filtered analog air conditioner head pressure gage value.kPa
AC_Pressure_Error_CountsSensors / calibrationelapsed AC Pressure error count durationNone
AC_Pressure_LearnedSensors / calibrationStatus indicating AC pressure sensor is in range.None
AC_Pressure_No_High_OR_Low_FltsSensors / calibrationStatus indicating there are no AC Pressure High or Low Error faults. TRUE - If both AC Pressure High and Low Error faults are not there FALSE if either AC PreNone
AC_Pressure_Not_HighSensors / calibrationStatus indicating AC Pressure is not higher than the threshold for AC to switch On TRUE - If AC Pressure is less than the threshold FALSE - If AC Pressure is None

Sample of named calibration parameters with their Cummins descriptions. The full ECFG lists every parameter with ITN address, data type, scaling, limits and units.

Other BHQ versions (80)

51.19.1.0ECFG · CM2450 · 2018-10-3051.19.1.8ECFG · CM2450 · 2019-03-0251.19.3.0ECFG · CM2450 · 2019-04-1851.19.4.2ECFG · CM2450 · 2019-09-0651.19.5.0ECFG · CM2450 · 2019-10-1651.19.7.0ECFG · CM2450 · 2020-02-1451.19.9.2ECFG · CM2450 · 2020-09-2451.19.40.62ECFG · CM2450 · 2018-07-3151.19.40.71ECFG · CM2450 · 2018-09-1451.20.0.2ECFG · CM2450 · 2018-09-2151.20.0.3ECFG · CM2450 · 2018-11-0151.20.1.7ECFG · CM2450 · 2019-10-3151.20.2.0ECFG · CM2450 · 2020-02-1851.20.3.0ECFG · CM2450 · 2020-06-0951.20.4.0ECFG · CM2450 · 2020-09-2951.20.5.0ECFG · CM2450 · 2020-09-3051.21.0.6ECFG · CM2450 · 2019-11-1351.21.0.53ECFG · CM2450 · 2020-05-2651.21.1.0ECFG · CM2450 · 2020-07-1551.21.2.0ECFG · CM2450 · 2020-10-0551.22.0.0ECFG · CM2450 · 2020-07-2951.23.3.1ECFG · CM2450 · 2020-09-0252.19.0.5ECFG · CM2450 · 2016-08-0452.19.0.5ECFG · CM2450 · 2016-08-0452.19.1.0ECFG · CM2450 · 2018-10-3052.19.1.1ECFG · CM2450 · 2018-11-0852.19.1.3ECFG · CM2450 · 2018-12-2852.19.1.8ECFG · CM2450 · 2019-03-0252.19.3.0ECFG · CM2450 · 2019-04-1852.19.4.1ECFG · CM2450 · 2019-09-0652.19.7.0ECFG · CM2450 · 2020-02-1952.19.9.2ECFG · CM2450 · 2020-09-2452.19.44.52ECFG · CM2450 · 2018-05-3152.19.44.52ECFG · CM2450 · 2018-05-3152.19.44.52ECFG · CM2450 · 2018-05-3152.19.44.62ECFG · CM2450 · 2018-07-3152.19.44.71ECFG · CM2450 · 2018-09-1452.19.82.16ECFG · CM2450 · 2017-05-0552.20.0.2ECFG · CM2450 · 2018-10-0552.20.0.3ECFG · CM2450 · 2018-11-0152.20.0.61ECFG · CM2450 · 2019-05-0752.20.1.7ECFG · CM2450 · 2019-10-0652.20.1.8ECFG · CM2450 · 2019-10-3052.20.2.2ECFG · CM2450 · 2020-01-1852.20.3.0ECFG · CM2450 · 2020-02-1452.20.4.0ECFG · CM2450 · 2020-06-0952.20.5.0ECFG · CM2450 · 2020-09-2952.20.6.0ECFG · CM2450 · 2020-09-3052.21.0.3ECFG · CM2450 · 2019-09-0952.21.0.9ECFG · CM2450 · 2019-11-2152.21.0.11ECFG · CM2450 · 2020-01-1652.21.0.52ECFG · CM2450 · 2020-05-2052.21.0.53ECFG · CM2450 · 2020-05-2652.21.1.0ECFG · CM2450 · 2020-07-1552.21.2.0ECFG · CM2450 · 2020-10-0552.21.2.0ECFG · CM2450 · 2020-10-0552.22.0.0ECFG · CM2450 · 2020-07-2652.22.0.1ECFG · CM2450 · 2020-09-0252.22.1.0ECFG · CM2450 · 2021-05-0752.23.2.0ECFG · CM2450 · 2022-12-1352.23.2.1ECFG · CM2450 · 2022-12-2053.19.1.2ECFG · CM2450 · 2019-08-0553.19.1.3ECFG · CM2450 · 2019-09-1153.19.2.0ECFG · CM2450 · 2020-02-2053.19.44.52ECFG · CM2450 · 2018-06-1353.21.1.1ECFG · CM2450 · 2020-08-1853.21.2.1ECFG · CM2450 · 2021-01-1853.22.2.0ECFG · CM2450 · 2022-11-1754.19.1.2ECFG · CM2450 · 2019-08-0554.19.1.3ECFG · CM2450 · 2019-09-1154.19.2.0ECFG · CM2450 · 2020-02-2054.19.3.1ECFG · CM2450 · 2021-01-1854.19.44.52ECFG · CM2450 · 2018-06-1354.21.1.1ECFG · CM2450 · 2020-08-1854.21.2.1ECFG · CM2450 · 2021-01-1856.23.1.8ECFG · CM2450 · 2020-09-0291.21.0.0ECFG · CM2450 · 2020-01-2491.21.0.53ECFG · CM2450 · 2020-05-2692.21.0.0ECFG · CM2450 · 2020-01-2492.21.0.52ECFG · CM2450 · 2020-05-20
Buy & download
Loading checkout…
Custom file service on your .xcal: DTC / full delete, extra HP, VGT delete